Sound insulation testing is used to measure the resistance of sound provided by an element of a building (such as a floor or wall) between dwellings. It essentially measures the effectiveness of the sound proofing treatment installed as part of a build or property development. New structures and reconstructed developments have been mandated by the Building Regulations to test for sound upon completion, since Approved Document E (ADE) was reappraised in 2003.

Not having a sound insulation certificate issued after a test, has resulted in additional costs and expenses for developers. Any development that has not taken a sound test will not be given a completion certificate by Building Control. The significance of a sound insulation certificate cannot be overrated. Therefore, we ensure that you get the certificate speedily. We take great pride in providing our certificates to you as soon as possible after the tests.

Even before you get the certificate, you will receive the results of the test. First, our skilled and competent sound insulation test will engineers give you a verbal result at the site. Then, a written report is sent to you within 24 hours of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

How Sound Testing Works

Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

What is part of a Sound Insulation Test

A sound insulation test creates a high amount of noise but needs a site with low noise levels to be taken effectively. As a result of this, workers in a testing area might have to leave the development temporarily, so that the test can be free from errors. Undertaking sound tests on site varies according to the size and complexity of the building project and the site conditions. A dwelling or development of normal size and simplicity will more than likely be tested in 90 minutes.

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern.

You will get a detailed written report and sound test certificate about a day after, if possible. Every 10 units in a group or sub-group are to be tested, according to ADE. A sub-group is stipulated in Section 1. Of ADE There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. How much testing that should be done on each group is listed below:

Why is Sound Insulation Testing Relevant?

Before completing a building, all new constructions should be tested for sound insulation, as stipulated by Approved Document E since 2003. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. This is to be certain that all new developments meet a uniform minimum criterion for resistance to sound from other parts of the development and adjoining developments. Sound affects our life no matter where we are, at home, work or while relaxing. Places with lowered noise are more comfortable and enabling. Sound testing ensures that noise reduction in a building is effective.

Insufficient sound insulation causes distress and comfort while an effective sound insulation system brings about speech privacy. This is one of the several reasons why sound insulation is a key element in building. For instance, in an apartment building, the neighbour upstairs might invite friends over during the weekend and put on loud music. The inhabitant downstairs might spend night hours as work time. If the sound insulation is inefficient, this could lead to lots of problems. This is just one instance of the influence of sound insulation on our lives. In a structure with flats for mixed purposes, a sound insulation test will make sure that there is maximum sound resistance from party walls and floors and less noise.

Does Your Development Need a Sound Insulation Test?

Are you converting your property into several units? Does your design not use Robust Details? Are you constructing a new building with more than two rooms? Are you building a nursing home or rooms that will used for residential purposes, like hotels and hostels? If so, your structure needs to undergo a sound test. It is imperative that sound insulation tests be undertaken, as explained and stipulated by ADE.

There are two ways in which to show compliance. You can either test to the regime set out in Approved Document E (ADE), or pay to use Robust Details. Robust details are separating elements that have been pre-tested and conform to Approved Document E sound insulation standards. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. Sound insulation testing is a more flexible approach. You can pick from a plethora of designs, as opposed to Robust Details. It also gives architects the opportunity to evaluate their design and give your structure a much better sound insulation which will increase sound performance.

How much does sound insulation testing cost?

Simply contact us and we will be able to provide a free, no obligation quotation as to the requirements and costs for your development. We have handled all kinds of sound insulation projects in UK and issue a report and certificate as quickly as possible. Our prices are affordable too and can beat others.

Ideal Period for a Sound Insulation Test

Ideally, we would conduct a test when a development nears completion, and once all internal and external doors and windows have been fitted. We can test earlier to check if there are any problems. These are the things we need to conduct the test:

  • 240V power supply
  • A quiet environment
  • Access to all the units of the structure unless places to test have been decided before then.

How a Sound Test is Done

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

A big or multidirectional speaker, with a generator of pink or white noise is used to the biggest room. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. When conducting airborne sound insulation tests, two speakers are placed in each source room. The noise level in the receiving room is measured to get the sound difference between the source and receiving room.

The variations or differences in noise level are ‘corrected’ to take into consideration the already present background noise in the receiving room and the reverberation time – measure of time needed for a sound to decay or be absorbed in a closed room by 60dB. Impact tests are conducted by fixing a tapping machine on the floor. Noise level in the room below is measured at various different frequencies. Once the calculations are completed and the result is achieved, it is compared with Building Regulations Part E standards. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. Airborne sound test is the measurement of sound moving through the air through a wall or floor. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. Sound level meter is also used for impact tests. Alongside it, a tapping machine that drops metal hammers is used. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. Test results, which are approved by Building Control and used to sign off the building, are recorded in a report and sent to the client.

Sound insulation testing is essential for these dwelling types:

Sound testing measures the impact and airborne sound moving through new and old adjoining buildings. This could affect the separating walls between buildings or in-between the spaces in a development.

A new building with not less than two rooms

This makes sure that the sound insulation for the building meets all the necessary requirements.

Converting a single development to flats

All the units that have been built are to be constructed in alignment with Part E of Building Regulations.

Using designs where Robust Details are not included

Architects are able to use pre-tested and approved Robust Details design for partitioning walls and floors. The Robust Details scheme was formed in 2004 by Robust Details Ltd. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Areas in the UK AF Acoustics Conduct Test

AF Acoustics renders acoustics design services and consultancy to customers all over the UK, especially in Rye. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. We’re based in several strategic locations in the south east of UK to enable you get the best quotation and price possible.

Why you should choose AF Acoustics

Having rendered high quality service to numerous customers in Rye, we have gotten great positive feedback and recommendation from our clientele due to the following:

Sound testing experience of over 15 years

We are able to offer helpful functional solutions that will solve our customer’s needs. We also have a track record of providing superior acoustic services to our customers (home and business owners) in the UK in small and large projects, giving them astounding value for their money.

Great prices

To make certain that all clients in Rye can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Rye. Contact us right now to get a quotation that’s completely free of charge.

Effective and quick consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. When you reach out to us for professional guidance, we make it a priority and deliver accurate answers fast. We recommend effective solutions that are most in line with your current and long-term needs.

Flexible test dates

Our test date options let you pick what will suit your schedule because your comfort is essential to us. If you want to schedule sound insulation testing in Rye, phone or email us immediately.

You get your report the next day

We try to provide test reports within 24 working hours. That way, you can take the right action based on the results of the test. The conveyed report will be exhaustive, covering every issue point by point to guarantee that the best suggestions are given.

AF Acoustics sound testing services

AF Acoustics offer a variety of complete acoustic slutions to clients all over the Uk, Contact us now for more information on how we can assist you with your acoustics requirements.

Impact and airborne floor test

These are taken on separating floors/ceilings between residences. The calculation of the sound level transferred from one unit to another through a separating floor via impact is called an impact test. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

Approved Document E test

AF Acoustics sound testing adheres to ADE which stipulates information bearing on the sound resistance and performance of a property. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Sound test

Our services and expertise is unbeatable and we are glad to work with our clients to help pass their sound insulation tests. In new build properties an airborne test or an airborne and impact test may be required to ensure it meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We frequently give robust advice to project managers and developers from the start of the construction, ensuring that they’ll have adequate sound insulation to pass a sound test. Contact us today for more information about our sound testing services or to book a no obligation quote, free of charge.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) explains minimum performance standards for the acoustics of school buildings. It also describes the normal means of demonstrating compliance with the Building Regulations. If building a new school in Rye, we can test the school to check if it meets the requirements of BB93.

Acoustic plan details

AF Acoustics provide detailed acoustic design services and consulting on a wide range of buildings. We have the capability and experience to develop customised solutions, and have a strong working knowledge of available proprietary acoustic products. We will develop detailed design solutions suitable for the specific demands of the project.

It is critical to get right professional assistance ahead of schedule from a highly qualified acoustic specialist. AF Acoustics can assist you with identifying the right acoustic propertiesfor your project at very early on in the construction process and tell you the best way to get them, utilizing a deep know-how of acoustic design.

We can assist with:

Acoustic detail design for architects engaged with residential improvements in consistence with Part E Building Regulations, BS8233 and so on. Detail plans for the educational, commercial and healthcare industry so as to meet with the current criteria. Specification and design of building services for noise control in residential and other noise sensitive scenarios Public address and sound reinforcement (conference rooms / lecture theatres etc.)

Get a sound insulation testing quotation by contacting our experts

Our services at AF Acoustics include acoustic design and investigation, evaluation and calculation of noise, acoustic survey, building an architectural acoustics and air pressure testing. Our professional guidance and advice is provided to private individuals, businesses and government agencies amongst others. You can contact us by sending us an email on info@af-acoustics.com or calling us for a free quote.

020 3372 4430 Contact us

Please send the following information to us

Give us the following information when contacting us

The development’s location

Where is your development situated in Rye

How many dwellings are there?

Tell us how many dwellings you have in the property.

Number of Storeys

For an accurate calculation of the quote, tell us the number of storeys

Configuration of dwellings (no. of units per level)

To help us get you an accurate quotation and evaluate the scope of the test to be taken, tell us how many dwellings there are per floor.

Kind of structure

Knowing the kind of building is essential because it helps identify the type of test that will be conducted.

Newly completed construction or conversion

These two go require different types performance, so let us know which one it is and you’ll get an accurate test and quotation.

Building regulations for sound test

Our ADE compliant sound tests can help you gain credits for Code for Sustainable Homes and EcoHomes environmental assessment structures.

Part E of building regulations resistance to the passage of sound (England and Wales)

We can have fully accredited engineers sent to your property at your convenience to provide certification for Building Regulations Part E compliance, recognised by Building Control.

Standard division for developments (Scotland)

Section 5.1 of the Scottish Building Standards states “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be taken at the completion of the building, using procedures given in annex 5.C. of the Scottish Standards. These standards don’t apply to detached structures that have access only for maintenance or are to used only by the occupants who live below.

Passing a sound insulation test

The most efficient way to make sure you pass sound insulation test is to have a plan that puts sound insulation into consideration from the begining. You don’t have to spend too much for this and it will save you money in the long run, ensuring you don’t pay remedial or re-test expenses. If you’re not certain of how to construct your party walls and floors, to meet Document E 2003 targets, simply contact us for an efficient design service. We can study design reports, complete site visits and sound test the development to provide you with the level of assessment and consultation that your project requires from start to finish. The are required in order to have good conditions to undertake the sound insulation tests: Windows and internal and external doors are fitted and operable Skirting boards are fixed are sealed Plug sockets, light switches and fittings are in place and working. Our experienced acoustic consultants work with developers, contractors, architects and planners of all sizes from the early design stage to help minimise any potential issues right through to project completion, ensuring that all properties are compliant with Building Regulations Document E 2003.

Investigation and report certificates

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern. A full report and individual sound test certificates can be generated and sent out usually the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

How the results are

Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. We can provide professional advice on designs that will surpass Document E standards if the building fails the test.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed