Sound insulation testing is used to measure the resistance of sound provided by an element of a building (such as a floor or wall) between dwellings. It essentially measures the effectiveness of the sound proofing treatment installed as part of a build or property development. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

Not doing so is a costly venture for developers and contractors as Building Control will not give a completion certificate for developments that have not undergone the test. Because we understand how the sound insulation certificate affects your building project, we ensure that you get it as quickly as possible after the test. In fact, we pride ourselves on issuing our sound insulation testing certificates as quickly as possible.

AF Acoustics’ competent and well-trained engineers, who will be available for testing, can even let you know the verbal results of your sound test. You will receive a written report in the space of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Testing Does

To adhere to Building Regulations ADE requirements, adjoining walls, floors and ceilings in a building will have to be tested, except where licensed Robust Details were used. The airborne and impact sound going through new and old structures are evaluated by sound testing. This can impact adjoining walls and floors between the structures.

What is part of a Sound Insulation Test

Workers on a site will vacate the premises while the sound test is being conducted. This will facilitate an enabling and quiet environment for the tests to be carried out. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. If the site is simple and of regular size, it typically takes about 90 minutes to complete the sound test.

After the test, the sound insulation test engineers will let you know the outcome of the test and supply simple feedback of important things noted during the test; e.g. problems that might occur in the future.

A full and thorough report with the certificate of the test will be given to you within 24 working hours. The way a sound test is conducted is determined by ADE of Building Regulations. It mandates that in all developments, every 10 units in a group or sub-group will undertake one set of tests. It explicitly states what a sub-group is in Section 1. ADE also states the categories of developments that should be tested. There are three: rooms, flats and houses (including bungalows) that are lived in. Examples are student accommodation, hotel rooms and care homes. How much testing that is required for each category can be found below.

Importance of Sound Insulation Testing

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. This Approved Document, as part of UK Building Regulations helps to ensure that new buildings are constructed to minimum standards that provide reasonable resistance to sound from other parts of the same building and from adjacent buildings. Sound testing is essential due to the fact that sound impacts us wherever we are, whether it’s at home, leisure or the office. Reduced noise in the partitions and flooring of a structure leads to greater ease and a more efficient environment.

Insufficient sound insulation causes distress and comfort while an effective sound insulation system brings about speech privacy. This is one of the several reasons why sound insulation is a key element in building. Let’s take a look at this scenario. An individual living in a block of flats might spend the weekend with friends relaxing and playing loud music. If the sound insulation on adjoining walls and floor is insufficient, the music will be distressful to neighbours, especially if they work at night. This is just one example of how sound insulation can affect the quality of life of people in different ways. In a structure with flats for mixed purposes, a sound insulation test will make sure that there is maximum sound resistance from party walls and floors and less noise.

Do You Need a Sound Test?

If you’re doing one of the following, then you need a sound test:

  • Constructing a building that has two or more units
  • Constructing a nursing home or rooms that will be lived in, e.g. hotel room or hostel
  • Converting a single development to flats
  • Using designs where Robust Details are not included

Document E of the Building Regulations explains sound insulation testing and makes it a necessity.

There are two ways in which to show compliance. You can either test to the regime set out in Approved Document E (ADE), or pay to use Robust Details. If you choose the latter, you must use Robust Details which are a approved design details for partitioning walls and floors. When you use it, you don’t have to take a sound insulation test. However, you must abide strictly by the design from the Robust Details approved list. With sound testing, however, you’re free to pick from any design, including more cost effective and appropriate ones. This makes it a more efficient process than Robust Details. Sound insulation testing can also help architects enhance their building design and in turn the sound insulation of the building.

How Much Will I Pay for a Sound Insulation Test?

We can send quotation that’s completely free of charge and is based on the kind of development you have. Our prices are extremely competitive and we’ve worked on developments of various sizes and types. You’re also assured of a quick turnaround time for your sound insulation test report and certificates.

Sound Insulation Test Time

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

How is Sound Insulation Testing Done?

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

The airborne sound insulation test is carried out with a large speaker or dodecahedron speaker, using a white or pink noise generator to create the source sound, almost always in the largest room of the two rooms under testing. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. Background sound is also calculated. Noise in the receiver room should be 10dB more than the background noise at all frequency measurements, so source noise is set to be greater than background noise. Airborne sound tests are conducted in this manner: two singular speaker positions are used for every source room. The noise in the receiver room is measured to determine the variations in noise level between the source and receiver room.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact tests are done by placing a standardised tapping machine on the floor. The room under it is then measured for the noise levels. Calculations are undertaken, and results achieved. The results are crosschecked to ensure they meet Document E of Building Regulations target. Of course, this is a simple way of describing the procedure followed when a sound test is carried out, but it enables you to understand it better.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

Our licensed engineers use UKAS calibrated equipment to measure sound insulation according to the present standards of Building Regulations. The calculation of the level of noise transmitted through the air between two adjoining units is known as an airborne sound insulation test. We use pink or white noise generator and speakers on one side of the partition. A sound level meter is used on calculating sound in both units. Sound level meter is also used for impact tests. Alongside it, a tapping machine that drops metal hammers is used. The tests are carried out in rooms suitable for residential use like bedrooms, lounges and kitchens. Test findings are fed into a report that will be sent to the client. This report will always be acceptable to Building Control and will help you to get your development signed off.

Sound Insulation Testing is necessary for these types of builds:

Sound insulation tests examine airborne and impact sound moving through buildings. It is usually undertaken between party walls and floors between buildings or between spaces within a new development.

A structure with 2 or more units/flats

This is to ensure that the sound proofing of the building is up to standard for residential purposes.

Converting a single development to flats

All the units that have been built are to be constructed in alignment with Part E of Building Regulations.

Design not using Robust Details

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. The minimum requirements during testing will depend on a variety of factors such as if the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

Areas in the UK AF Acoustics Conduct Test

AF Acoustics renders acoustics design services and consultancy to customers all over the UK, especially in Watford. We work with architects, planning and environmental consultancies as well as private individuals and government agencies. Our consultants can be found in various places in the south east region. This way you get an affordable price.

Why you should pick AF Acoustics for your sound testing

We have helped many homes and business owners in Watford with their sound tests and building’s sound performance. Our customers endorse and recommend us because of the following advantages of working with us.

Over 15 years’ experience

Our experience of over 15 years has enabled us understand our clients need and industry extensively. As a result, our advice is applicative, serviceable and will meet the client at the point of their needs. By doing this, we have been able to continuously satisfy clients in the UK and meet their acoustic needs for over 15 years, providing great value for money.

Competitive rates

To make sure you can afford high quality sound insulation projects in UK, we offer one of the most affordable prices in Watford. Contact us immediately and we’ll give you a free quote on the sound test.

Ultrafast and efficient consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. We will give you the right answers and expert guidance so that you can get effectual solutions to your problems.

Flexible test dates

Your convenience is also important to us. This is why we offer you flexible options that let you pick test dates that are most convenient for you. Take the first step towards your sound insulation testing in Watford by calling us now.

Get your test reports quickly

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. The conveyed report will be exhaustive, covering every issue point by point to guarantee that the best suggestions are given.

The sound testing services we provide

AF Acoustics provide a scope of exhaustive and detailed acoustic solutions for clients across the country, making certain our techniques have the best quality and performance. Call or mail us today so we can provide you with more knowledge on your acoustics needs.

Airborne and impact ceilings/floor tests

These are performed on floors and/or ceilings between units. An impact test measures the levels of noise transmitted directly through a separating construction. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

Document E test

Our sound insulation tests meet the requirements of Building Regulations Part E, which describes building structures resistance to the movement of sound within and from adjoining structures. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound Insulation Testing

We want to give our customers the most highest chance to acquire a pass and via our offer skilled services. In new properties, an airborne and impact test will help you guarantee the building meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly provide consultations for project managers and developers from the very start of developments, ensuring peace of mind when it comes time to having a sound test. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Acoustic design testing in schools in line with BB93

Building Bulletin 93 (BB93) explains the sound performance requirement for the acoustics of school buildings. It likewise states how a school can meet this requirement. If you’re constructing a new school in Watford, we can test the sound performance to evaluate if it meets the standards of BB93.

Acoustic layout

AF Acoustics give definite design services and consultancy services to all types of developments. We create bespoke solution and can provide information on the best available acoustic products. We will tailor our design solutions to your project.

Getting advice on the acoustics of a development as early as possible is crucial. AF Acoustics can enable you to do that by advising you on the appropriate acoustic requirements of your property very early in the building process and recommending what to do to fulfil them.

We can assist with:

Creating acoustic detail plans for architects involved in residential construction that conform to Document E of Building Regulations, BS8233 and so on. Detail designs for the health, educational and commercial projects in order to meet up with the necessary requirements. Specifications and design details that enable good sound insulation and reduction of noise in residences. Public address and sound reinforcement (conference rooms / lecture theatres etc.)

Contact our professionals for a sound test quotation

As an independent acoustics consultancy, AF Acoustics is able to provide extensive acoustic survey and design, investigations in the field of planning and noise, architectural and building acoustics, and air permeability testing. Whether you are a company or a private individual, we are here to advise and guide you. If you would like a friendly and accurate sound insulation testing quote, please send an email to info@af-acoustics.com or give us a call.

020 3372 4430 Contact us

We will need the following information:

When calling or emailing us please provide the following data

Location of property

Where is your development situated in Watford

How many dwellings are there?

Total number of dwellings in the building.

Total number of floors

To give you an appropriate quotation, would like to know the number of floors in your building.

Number of dwelling units per storey

Tell us how many units are in your structure so that we can give you the right calculation for your quotation and know the scope of the test.

Type of development

What is your building type? This will help us know the kind of test it will undergo.

New construction or refurbished building

Newly completed constructions and refurbished structures have different requirements for sound insulation testing. This is why it’s important to provide this information beforehand. Our quotation is available at any time.

Building regulations for sound test

Get more credits for Code for Sustainable Homes and EcoHomes environmental assessment project by taking a sound insulation test which are aligned with approved document E building regulations rules.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

Our expert engineers can issue certificates for the sound insulation testing. They can visit the site and conduct the test that will lead to getting a certificate which is in line with Building Regulations and Building Control requirements.

Scotland Standard division for completed constructions

In the words of Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests, which are conducted after building utilizing the methodology given in annex 5.C. of the Scottish Standard 5.1 does not apply to: completely disconnected houses, rooftops and walkways with access exclusively for the use of the occupants of the home underneath.

How to pass a sound test

Make sure you pass your sound test by having efficient sound insulation included in the building design. It saves time and money and helps you avoid repair work and re-test expenses. If you are unsure of how to build the separating floor and wall constructions and associated junctions across your development to satisfy the requirements of Document E 2003, we can offer design advice. We can study design reports, complete site visits and sound test the development to provide you with the level of assessment and consultation that your project requires from start to finish. Take the following action to give your building the best opportunity to pass the sound insulation test: All windows and doors have been fitted and work Skirting boards are fitted and sealed Light fittings and switches and plug sockets are fitted and working. Our expert acoustic consultants work with planners, developers, architects and contractors from the beginning of the design stage till when the property is finished to ensure it meets the conditions of Document E 2003.

Certificates for test evaluation and report

After the test, AF Acoustics’ competent and well trained engineers can let you know the verbal results of your sound test and provide feedback on issues noticed during the test. We endeavour to send an investigation and report certificate the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The way the results look

A certificate will be issued to you whether the sound insulation treatment of the building meets the requirements of Document E of Building Regulations or not. If a partition wall or floor does not comply with Part E standards, repair work and another sound test will be needed. We can give robust advice on that to ensure you pass.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed