Sound insulation testing is used to measure the resistance of sound provided by an element of a building (such as a floor or wall) between dwellings. It essentially measures the effectiveness of the sound proofing treatment installed as part of a build or property development. The Building Regulations Approved Document E (ADE) states all new dwellings and renovated constructions should undergo sound testing.

Not having a sound insulation certificate issued after a test, has resulted in additional costs and expenses for developers. Any development that has not taken a sound test will not be given a completion certificate by Building Control. The significance of a sound insulation certificate cannot be overrated. Therefore, we ensure that you get the certificate speedily. When the tests are completed, we work quickly to issue your certificates; we take great pride in our efficiency.

Our highly capable sound test engineers will be available on site when you need them. They will give you a verbal result of the test, once taken and a written report will be issued to you by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Testing Does

To adhere to Building Regulations ADE requirements, adjoining walls, floors and ceilings in a building will have to be tested, except where licensed Robust Details were used. The airborne and impact sound going through new and old structures are evaluated by sound testing. This can impact adjoining walls and floors between the structures.

What is involved in Sound testing?

While producing lots of noise, sound test needs a quiet site to be conducted efficiently. Due to this fact, the workers in the site should not be present at the time of the test. Undertaking sound tests on site varies according to the size and complexity of the building project and the site conditions. A dwelling or development of normal size and simplicity will more than likely be tested in 90 minutes.

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. The sound insulation testing methodology has been outlined by Document E of the Building Regulations. The document states that every 10 units in a sub-group or group should undergo one set of test, and defines a sub-group in Section 1. There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. Find below the testing stipulation for each kind of development.

Why Sound Testing is Required

Document E of Building regulations, from 2003, made it compulsory for all new UK constructions to undertake a pre-completion sound test. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. This is to be certain that all new developments meet a uniform minimum criterion for resistance to sound from other parts of the development and adjoining developments. When sound resistance is high in party walls and floors, the environment is more comfortable, since sound affects every aspect of our lives – work environment, home environment and while relaxing. This is why sound testing is crucial.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. This is just one instance of the influence of sound insulation on our lives. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

How to Know if You Need Sound Insulation Testing

You need sound insulation testing if you:

  • Build a new development of 2 or more dwellings / flats
  • Convert a former single dwelling into flats
  • Build a Nursing Home or rooms for residential use, i.e. hotel or hostel
  • Have designs which do not adhere to Robust Details

Sound insulation is covered and made mandatory under Approved Document E of The Building Regulations.

There are two ways in which to show compliance. You can either test to the regime set out in Approved Document E (ADE), or pay to use Robust Details. If you choose the latter, you must use Robust Details which are a approved design details for partitioning walls and floors. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. Sound testing provides more flexibility by allowing different designs and is often therefore more cost effective in many ways compared to the Robust Details Scheme. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.

Cost of Sound Insulation Testing

To get a free quote for your dwelling, contact us. We have worked throughout the country on all sizes of project, and should a sound insulation report and certificates be required, we can provide the fastest turnaround times and most competitive prices available. If you get a better quote elsewhere, simply forward it to us and we will try and beat it!

When can I carry out the sound insulation tests?

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. For your sound tests to be conducted successfully we need the property to be quiet, with workers not near the rooms to be tested during the test time (a noisy environment makes the test difficult and sometimes unsuccessful). We also need access to all units unless the test program has been compiled earlier. Finally, we need 240V power supply.

The Procedures of a Sound Insulation Test

The method of taking the test is not complex and our sound test engineers can explain it thoroughly on site, if you wish. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

The airborne sound insulation test is carried out with a large speaker or dodecahedron speaker, using a white or pink noise generator to create the source sound, almost always in the largest room of the two rooms under testing. A sound level meter calculates the noise in the source room and receiver room. Background sound is also calculated. Noise in the receiver room should be 10dB more than the background noise at all frequency measurements, so source noise is set to be greater than background noise. When conducting airborne sound insulation tests, two speakers are placed in each source room. The noise level in the receiving room is measured to get the sound difference between the source and receiving room.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact tests are done by placing a standardised tapping machine on the floor. The sound pressure level at the receiving room, which is below the source room, is measured. Calculations are undertaken, and results achieved. The results are crosschecked to ensure they meet Document E of Building Regulations target. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. An airborne sound test measures levels of sound transmitted through the air through a separating element. Equipment used for the test include a noise generator, speakers and sound level meter. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. The tests are administered in room with residential purposes. For example, kitchens/living spaces, lounges, bedrooms and living rooms. Test results, which are approved by Building Control and used to sign off the building, are recorded in a report and sent to the client.

Sound insulation testing is essential for these dwelling types:

For sound testing we usually undertake impact and airborne sound test on buildings. This affects the separating floors and walls between habitable rooms of buildings and developments.

Property with two or more units

This makes sure that the sound insulation for the building meets all the necessary requirements.

A single dwelling that was turned into a development with several flats or units

When the development is completed, ADE of Building Regulations should be checked, and sound insulation tested accordingly.

Using designs where Robust Details are not included

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. If the building design does not strictly adhere to Robust Details, a sound insulation test becomes necessary to meet Building Regulations. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Towns in the UK AF Acoustics Services can be Found

AF Acoustics is an acoustic consultancy providing acoustic design services to clients nationwide, especially in Barking. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. We’re based in several areas across the south east region of UK so that we can give you the most cost effective quote in the industry.

Why you should pick AF Acoustics for your sound testing

We have worked with many organisations and individuals in Barking. Our clients have endorsed us for the following reasons:

More than 15 years’ experience

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. In more than 15 years, we have acquired extensive experience with providing acoustic solutions to private individuals and organisations in the UK, no matter the size or scale of the project. You get expedience and value for the price.

Affordably rates

To ensure all clients in Barking can afford superior quality sound insulation testing, we offer some of the most competitive rates you can both in and outside Barking. If in doubt, contact us now for a free no-obligation quote.

Fast and efficient consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. When you reach out to us for professional guidance, we make it a priority and deliver accurate answers fast. We recommend effective solutions that are most in line with your current and long-term needs.

Test dates that are flexible

Because your convenience is important to us, we provide several options to help you choose a test date that is best for you. Call us now to schedule sound insulation testing in Barking

Test reports arrive the next day

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. We make certain all relevant issues are covered and quality tips are supplied by detailing all the aspects of the test in the report.

Sound Insulation Testing Services We offer

AF Acoustics provide a scope of exhaustive and detailed acoustic solutions for clients across the country, making certain our techniques have the best quality and performance. Phone or email us today for more information on how we can help you with your acoustic requirements.

Airborne and impact tests for floors/ceilings

These are taken on separating floors/ceilings between residences. The calculation of the sound level transferred from one unit to another through a separating floor via impact is called an impact test. Airborne and impact tests are conducted on the floor partitions between liveable rooms.

Document E test

Document E of Building Regulations requires certain criteria for the sound performance of a dwelling. Our sound insulation tests are conducted in accordance to these criteria. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound Insulation Testing

With our professional and highly skilled expertise, we are willing to work with our clients to help them get a pass certificate in every situation. A new dwelling may have to undergo an airborne and impact test to meet the benchmark of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Contact us today for more information about our sound testing services or to book a no obligation quote, free of charge.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 testing of acoustic design in schools

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. If you’re constructing a new school in Barking, we can conduct a test to be certain it meets the standards of BB93.

Acoustic plan

AF Acoustics give definite design services and consultancy services to all types of developments. We create bespoke solution and can provide information on the best available acoustic products. We will tailor our design solutions to your project.

When constructing a building, it’s vital you get advice from the right acoustic consultant on time. AF Acoustics uses professional expertise to discover your acoustic needs early on and proffer ideas on how to meet them.

We can assist with:

Acoustic detail layout for architect developing structures complying to Building regulations, BS8233 and so on. Detail plans in commercial, educational and healthcare project for adhering to the prescribed standard. Designs and specifications that ensure good sound performance of buildings in residential areas and other noise sensitive places. Improving sound and public address system in halls, conference rooms etc.

Contact our professionals for a sound test quotation

AF Acoustics is a leading acoustic consultancy. It provides the following services: architectural and building acoustics, acoustics design, survey and investigation in the field of planning and noise, and examining and controlling air vibrations while conducting air leakage tests. Whether you are a company or a private individual, we are here to advise and guide you. If you would like a friendly and accurate sound insulation testing quote, please send an email to info@af-acoustics.com or give us a call.

020 3372 4430 Contact us

Provide us with the following data

When calling or emailing us please provide the following data

Location of property

Provide the location of your building in Barking.

How many dwellings are there?

Total number of dwellings in the structure

Number of floors in the building

For an accurate calculation of the quote, tell us the number of storeys

Dwellings configuration per floor

Tell us how many units are in your structure so that we can give you the right calculation for your quotation and know the scope of the test.

Type of development

The type of building, as different building types typically require a different testing.

Newly completed construction or conversion

These two go require different types performance, so let us know which one it is and you’ll get an accurate test and quotation.

Sounds test in accordance with building regulations

We undertake sound insulation test on various buildings that adhere to Building Regulations Document E. Testing can also enable you get more credits for Code for Sustainable Homes and EcoHomes environmental assessment constructions.

Sound resistance: approved document of building regulations (England and Wales)

We can have fully accredited engineers sent to your property at your convenience to provide certification for Building Regulations Part E compliance, recognised by Building Control.

Scotland Standard division for properties

Section 5.1 of the Scottish Building Standards states “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be taken at the completion of the building, using procedures given in annex 5.C. of the Scottish Standards. These standards don’t apply to detached structures that have access only for maintenance or are to used only by the occupants who live below.

Passing a sound insulation test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. If you are unsure of how to build the separating floor and wall constructions and associated junctions across your development to satisfy the requirements of Document E 2003, we can offer design advice. We can study design reports, complete site visits and sound test the development to provide you with the level of assessment and consultation that your project requires from start to finish. The following conditions will provide you with an ample chance of passing the sound test: Install and make sure that all external and internal doors and windows are operational Skirting boards are fitted and sealed Light fittings and switches and plug sockets are fitted and working. Our expert acoustic consultants work with planners, developers, architects and contractors from the beginning of the design stage till when the property is finished to ensure it meets the conditions of Document E 2003.

Certificates for test evaluation and report

To obtain a thorough evaluation of your building, we issue a report certificate within 24 working hours where possible. Our highly capable sound test engineers will give you a verbal result of the test, once the test is taken and proffer solutions to possible problems or future areas of concern. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

How the results are

Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. In the event of a wall or floor not achieving the Part E requirements, it may be necessary to carry out remedial works before having another sound test carried out. We can provide you with remedial design advice to help you achieve the Building Regulations requirements.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed