Sound testing calculates the extent to which sound is blocked by the partition (walls, floors etc) of a building between dwellings. It evaluates the efficiency of the soundproofing materials that make up the structure. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

Not having a sound insulation certificate issued after a test, has resulted in additional costs and expenses for developers. Any development that has not taken a sound test will not be given a completion certificate by Building Control. Because we understand how the sound insulation certificate affects your building project, we ensure that you get it as quickly as possible after the test. When the tests are completed, we work quickly to issue your certificates; we take great pride in our efficiency.

Even before you get the certificate, you will receive the results of the test. First, our skilled and competent sound insulation test will engineers give you a verbal result at the site. Then, a written report is sent to you within 24 hours of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Test?

To completely fulfil Building Regulations Part E requirements, the separating walls and floors of dwellings will be tested, unless approved Robust Details are used. Sound Insulation Testing tests for both the airborne sound and the impact sound which travels through new or existing buildings . The tests cover party walls and floors between new and existing buildings, or between spaces within a new development entirely.

What is involved in Sound testing?

Workers on a site will vacate the premises while the sound test is being conducted. This will facilitate an enabling and quiet environment for the tests to be carried out. Undertaking sound tests on site varies according to the size and complexity of the building project and the site conditions. A dwelling or development of normal size and simplicity will more than likely be tested in 90 minutes.

After the test, the sound insulation test engineers will let you know the outcome of the test and supply simple feedback of important things noted during the test; e.g. problems that might occur in the future.

A full report and individual sound test certificates can be generated and sent out the next day. Every 10 units in a group or sub-group are to be tested, according to ADE. A sub-group is stipulated in Section 1. Of ADE Buildings are divided into three kinds for the test – houses, flats and rooms built for or converted to residential dwellings, like student accommodation, care homes and hotel rooms. The volume of testing carried out on each group is written below.

Why Should Your Dwelling Undergo Sound Testing

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. ADE ensures that new building are resistant to noise from adjoining buildings and other rooms within the same building. Sound testing is essential due to the fact that sound impacts us wherever we are, whether it’s at home, leisure or the office. Reduced noise in the partitions and flooring of a structure leads to greater ease and a more efficient environment.

Insufficient sound insulation causes distress and comfort while an effective sound insulation system brings about speech privacy. This is one of the several reasons why sound insulation is a key element in building. Let’s take a look at this scenario. An individual living in a block of flats might spend the weekend with friends relaxing and playing loud music. If the sound insulation on adjoining walls and floor is insufficient, the music will be distressful to neighbours, especially if they work at night. This is just one instance of the influence of sound insulation on our lives. Then there are developments where each neighbouring room / flat / unit has mixed uses. If the development has passed the sound insulation test, noise is reduced to a minimum.

Does Your Development Need a Sound Insulation Test?

Your development needs a sound insulation test if it meets one of the following criteria:

  • It’s design does not have Robust Details
  • It’s a new building with 2 or more dwellings
  • It’s being constructed to be used as a residence, like a hotel room or a hostel, or as a nursing home
  • It was once a single dwelling but is being turned into a development with several flats or units.

Sound insulation is covered and made mandatory under Approved Document E of The Building Regulations.

There are 2 ways you can comply. Test for sound insulation using the method of Approved Document E or use Robust Details in your development. Robust Details are a set of specific design details for walls and floors that have been previously tested to show compliance and must be used if this route is selected. You also cannot expand or tweak the design from the Robust Detail Approved listing. However, you are exempt from the sound test. Being able to adapt your design to suit your needs is more efficient and costs less in the long run. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.

How Much Will I Pay for a Sound Insulation Test?

Contact us and we’ll give you a free quote on the sound test cost based on the requirements of your building. Our prices are extremely competitive and we’ve worked on developments of various sizes and types. You’re also assured of a quick turnaround time for your sound insulation test report and certificates.

Period Sound Insulation Test Should be Carried Out

The best time for a sound insulation test is just before the construction of the property is finished and after all windows and doors are fixed. However, in the case of a problem we can take the test before then. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

How is sound insulation testing carried out?

Sound insulation testing is not complicated. Our highly qualified engineers will be willing to explain it in detail on the site. The boundary floors and walls get airborne tests. Floors get an additional impact test.

The airborne sound insulation test is carried out with a large speaker or dodecahedron speaker, using a white or pink noise generator to create the source sound, almost always in the largest room of the two rooms under testing. The sound generated and received is measured with a sound level meter. Noise in the background is also calculated. More noise in the background means a higher level of source sound will be created since it’s supposed to be 10dB higher than background noise on all calculated frequencies. Airborne sound tests are conducted in this manner: two singular speaker positions are used for every source room. The noise in the receiver room is measured to determine the variations in noise level between the source and receiver room.

The variations or differences in noise level are ‘corrected’ to take into consideration the already present background noise in the receiving room and the reverberation time – measure of time needed for a sound to decay or be absorbed in a closed room by 60dB. A tapping machine is placed on the floor to execute an impact sound insulation test. The sound level in the room below it is recorded. Once the calculations are completed and the result is achieved, it is compared with Building Regulations Part E standards. Without the mathematical formulae used in the calculations, this is a simple explanation, however, it helps explain the testing process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Kind of Testing Equipments Used

You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. An airborne sound test measures levels of sound transmitted through the air through a separating element. The equipment we use are a sound level meter, loudspeaker and white or pink noise generator. Sound level meter is also used for impact tests. Alongside it, a tapping machine that drops metal hammers is used. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. Test results, which are approved by Building Control and used to sign off the building, are recorded in a report and sent to the client.

A sound test is mandatory for these buildings:

For sound testing we usually undertake impact and airborne sound test on buildings. This affects the separating floors and walls between habitable rooms of buildings and developments.

A structure with 2 or more units/flats

This makes certain that the dwellings have adequate sound proofing.

Converting a property into several units

The development that has been converted must conform to Building Regulations sound requirements.

Using designs where Robust Details are not included

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the design does not completely follow Robust Details, sound insulation testing will occur to be certain the building meets ADE criteria. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Areas in the UK AF Acoustics Conduct Test

As an acoustics design services firm, AF Acoustics provides acoustic consultancy to various individuals and businesses nationwide, especially in Beddington-Corner. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.

Why you should pick AF Acoustics for your sound testing

Having rendered high quality service to numerous customers in Beddington-Corner, we have gotten great positive feedback and recommendation from our clientele due to the following:

Sound testing experience of over 15 years

Our experience of over 15 years has enabled us understand our clients need and industry extensively. As a result, our advice is applicative, serviceable and will meet the client at the point of their needs. Our clients in the UK are completely satisfied with our acoustic solutions. Irrespective of the type of project you have, minor or major, you can be assured that we’ll give outstanding value for your money.

Competitive rates

We want to ensure that you get the best value for your money. That is why we have one of the most unbeatable rates in and outside Beddington-Corner. Call us or email today to get a free quotation.

Effective and quick consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Adjustable test dates

Your convenience is also important to us. This is why we offer you flexible options that let you pick test dates that are most convenient for you. Take the first step towards your sound insulation testing in Beddington-Corner by calling us now.

Get your test reports quickly

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. We make certain all relevant issues are covered and quality tips are supplied by detailing all the aspects of the test in the report.

Sound Insulation Testing Services We offer

With AF Acoustics, you get a highly effective and expert acoustic advice which our customers all over UK have benefited from. Telephone or email us today for more data on how we can assist you with your acoustic requirements.

Airborne and impact ceilings/floor tests

These are only carried out on separating floor/ceiling between dwellings. An impact test examines the level of noise moving from one dwelling to another through impact on adjoining floors/ceilings. These floors in habitable rooms of flats undergo both impact and airborne tests.

ADE testing

Our sound insulation testing in accordance with Building Regulations Approved Document E, which sets out details pertaining to the resistance to the passage of sound. For new buildings, results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. Converted structures expected impact sound results increases by 2dB L’nTw while the airborne sound results reduces by 2dB DnTw+Ctr.

Sound test

With our professional and highly skilled expertise, we are willing to work with our clients to help them get a pass certificate in every situation. A new dwelling may have to undergo an airborne and impact test to meet the benchmark of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We frequently give robust advice to project managers and developers from the start of the construction, ensuring that they’ll have adequate sound insulation to pass a sound test. Contact us today for more information about our sound testing services or to book a no obligation quote, free of charge.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Acoustic design testing in schools in line with BB93

Building Bulletin 93 (BB93) describes the minimum requirement for the acoustics of a school building. It also stipulates how a school can conform to Building Regulations. If building a new school in Beddington-Corner, we can test the school to check if it meets the requirements of BB93.

Acoustic Design

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

It is critical to get right professional assistance ahead of schedule from a highly qualified acoustic specialist. AF Acoustics can assist you with identifying the right acoustic propertiesfor your project at very early on in the construction process and tell you the best way to get them, utilizing a deep know-how of acoustic design.

We can assist with:

Creating acoustic detail plans for architects involved in residential construction that conform to Document E of Building Regulations, BS8233 and so on. Detail plans in commercial, educational and healthcare project for adhering to the prescribed standard. Specification and design of building services for noise control in residential and other noise sensitive scenarios Improving sound and public address system in halls, conference rooms etc.

Contact AF Acoustics specialist for sound insulation test quotes

At AF Acoustics, we are an independent acoustic consultancy. Our work embraces acoustic surveys, acoustic design and investigation work in the fields of planning and noise, architectural and building acoustics, the monitoring and control of vibrations and air tightness testing. We will give you sound advice and guidance no matter who you are or the kind of project you have. To get an accurate quotation, either call us or email info@af-acoustics.com

020 3372 4430 Contact us

We would like to know the following

When contacting us, please give us the following information

Place where the building is being built

Where in Beddington-Corner the property is situated

Total number of dwellings

Total number of dwellings in the structure

Number of floors in the building

For an accurate calculation of the quote, tell us the number of storeys

Number of dwelling units per storey

This will also be needed to determine scope of the testing and provide an accurate quote

Building type

Tell us the kind of property because different buildings require different amounts of tests.

New dwelling or converted property

Knowing if your building is new or converted allows us to give you a competitive quotation and prepare the right test for it.

Sound Insulation Testing Regulations

Get more credits for Code for Sustainable Homes and EcoHomes environmental assessment project by taking a sound insulation test which are aligned with approved document E building regulations rules.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

We can send our authorised engineers to your development whenever the timing is ideal to undertake sound insulation testing that conforms to Building Regulations Document E consistence, as accepted by Building Control.

Standard division for developments (Scotland)

According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be performed after construction, using the procedures given in annex 5.C. of the Scottish Standards. Standard 5.1 does not apply to: fully detached houses or roofs or walkways with access solely for maintenance, or solely for the use of the residents of the dwelling below.

How to make sure you pass your sound test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. We offer design services that help you construct separating walls and floors with good sound performance that meet ADE demands. Our consultation may include several site visits and thorough design reports, or more basic initial tests on your structure. The are required in order to have good conditions to undertake the sound insulation tests: All windows and door have been fixed and are functioning Fit and seal skirting boards Light switches, plug sockets, and light fittings are adequately fixed. We work with several professionals in construction from the beginning of the design stage to the completion of the development to make certain it conforms to Document E 2003 of Building Regulations.

Investigation and report certificates

We try to issue a certificate to give you the details of the test evaluation and report, by the next day. After the test, our site engineers will provide verbal results and advise you on how to solve potential problem or future areas of concern. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

How the results are

A sound insulation certificate will be issued whether the Sound Testing results and report indicate compliance with Part E of the Building Regulations or not. We can provide professional advice on designs that will surpass Document E standards if the building fails the test.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed