Sound insulation testing involves the use of specialist equipment to examine how much sound is reduced off by floors and walls, of a building. It checks if a dwelling’s sound proofing treatment meets the requirements set out in Approved Document E. The Building Regulations Approved Document E (ADE) states all new dwellings and renovated constructions should undergo sound testing.

At the completion of the test, a sound insulation certificate is issued. Without the certificate, Building Control will not release the building completion certificate to the contractors and developers of the project. The significance of a sound insulation certificate cannot be overrated. Therefore, we ensure that you get the certificate speedily. When the tests are completed, we work quickly to issue your certificates; we take great pride in our efficiency.

Our fully trained sound insulation test engineers can be on site when you need them. Your AF Acoustics engineer will give you immediate verbal results from the sound test, and you can will have a written report by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Testing Does

To adhere to Building Regulations ADE requirements, adjoining walls, floors and ceilings in a building will have to be tested, except where licensed Robust Details were used. Sound insulation tests examine airborne and impact sound moving between separating walls and floors. The tests include party walls and floors between structures or between spaces within a new development.

What is part of a Sound Insulation Test

While producing lots of noise, sound test needs a quiet site to be conducted efficiently. Due to this fact, the workers in the site should not be present at the time of the test. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. Most of the time the test will be conducted in 90 minutes, for a simple, regular sized construction.

After the test, the sound insulation test engineers will let you know the outcome of the test and supply simple feedback of important things noted during the test; e.g. problems that might occur in the future.

You will get a detailed written report and sound test certificate about a day after, if possible. The way a sound test is conducted is determined by ADE of Building Regulations. It mandates that in all developments, every 10 units in a group or sub-group will undertake one set of tests. It explicitly states what a sub-group is in Section 1. There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. How much testing that is required for each category can be found below.

Why Should Your Dwelling Undergo Sound Testing

Sound insulation testing is required because ADE of Building Regulations has made it compulsory for all new buildings to take a sound test prior to finishing construction. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. The aim of Approved Documet E of the Building Regulations is to establish a minimum standard for the reduction in noise levels between all dwellings in a new or refurbished building. Sound testing is essential due to the fact that sound impacts us wherever we are, whether it’s at home, leisure or the office. Reduced noise in the partitions and flooring of a structure leads to greater ease and a more efficient environment.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. Sound insulation impacts people’s lives in various ways. In a structure with flats for mixed purposes, a sound insulation test will make sure that there is maximum sound resistance from party walls and floors and less noise.

Does Your Development Need a Sound Insulation Test?

You need a sound insulation test if you’re:

  • Constructing a nursing home or residential rooms like hostel or hotel rooms,
  • Converting a building with a single dwelling into flats,
  • Constructing a property with two or more units,
  • Using designs without Robust Details to build

ADE thoroughly explains sound testing and makes it compulsory.

Either you follow the pre-completion sound testing process stipulated therein or you use Robust Details. This way, you have conformed to the requirements. Robust details are separating elements that have been pre-tested and conform to Approved Document E sound insulation standards. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. Sound insulation testing is a more flexible approach. You can pick from a plethora of designs, as opposed to Robust Details. On-site pre-completion sound insulation testing gives architects more insight and ability to make their design lead to constructions that have a higher sound performance.

How much does sound insulation testing cost?

Call us or email us to get a free quotation for your building. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

When Should the Sound Tests be done?

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

The Procedures of a Sound Insulation Test

Sound insulation testing is not complicated. Our highly qualified engineers will be willing to explain it in detail on the site. For partition walls, airborne tests are carried out. For floors there are two types, airborne and impact tests.

A pink or white noise generator and a large speaker is used for the test in the biggest room between the two undergoing testing. The sound generated and received is measured with a sound level meter. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. Airborne sound testing is done in a similar way. First, two speaker positions are used for each source room. Then, the level of sound in the receiver room is measured so that the difference in noise level between the two rooms can be calculated.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact tests are conducted by fixing a tapping machine on the floor. Noise level in the room below is measured at various different frequencies. Calculations based on these measurements are undertaken and the results compared to the Building Regulations Part E requirements for the given type of the building. Without the mathematical formulae used in the calculations, this is a simple explanation, however, it helps explain the testing process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

Our high-tech sound insulation machines are UKAS calibrated and our accredited expert engineers conduct the test using Building Regulations present criteria. An airborne test is used to check how much sound is moving through the air between partitions. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. For impact test, a tapping machine that makes impact sound by dropping metal hammers is used. A sound level meter is used to measure in the receiving room below the room the tapping machine is in. Testing can only be completed on ‘habitable’ rooms. Habitable rooms can be bedrooms, lounges, living rooms and open plan kitchen/ living spaces. Test findings are fed into a report that will be sent to the client. This report will always be acceptable to Building Control and will help you to get your development signed off.

Sound insulation testing is essential for these dwelling types:

Sound testing measures the impact and airborne sound moving through new and old adjoining buildings. This could affect the separating walls between buildings or in-between the spaces in a development.

A new building with 2 or more dwellings

This makes certain that the dwellings have adequate sound proofing.

Converting a property into several units

The transformation of a single dwelling property into flats must adhere to the sound insulation standards of Building Regulations.

Designs without Robust Details

The Robust Details scheme was set up in 2004 by Robust Details Ltd as a way to help architects and builders design and construct separating elements with the confidence that the separating wall and/or floor will be capable of achieving the sound performance parameters in Approved Document E, and comply with the Building Regulations. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. The minimum criterion is based on various factors such as the purpose of the development and if it is a permanent dwelling or rooms to be used as residences like students’ accommodations and hotels.

Areas in the UK AF Acoustics Conduct Test

AF Acoustics provides acoustic design services to customer nationwide, especially in Broad-Street. Our clientele also include government agencies, architects, and organisations involved in planning and environmental consultancy. We’re based in several areas across the south east region of UK so that we can give you the most cost effective quote in the industry.

Why AF Acoustics is the right choice for your sound insulation test

We have helped many homes and business owners in Broad-Street with their sound tests and building’s sound performance. Our customers endorse and recommend us because of the following advantages of working with us.

More than 15 years’ experience

We understand the industries our clients are in. Therefore, we provide advice that is technically adequate, useful and applicable. We also have a track record of providing superior acoustic services to our customers (home and business owners) in the UK in small and large projects, giving them astounding value for their money.

Competitive prices

We want to ensure that you get the best value for your money. That is why we have one of the most unbeatable rates in and outside Broad-Street. Call us or email today to get a free quotation.

Prompt and productive consultancy

We will interpret your problems and necessities, present you with vigorous ideas and provide acoustic advice through our extensive experience. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Test dates that are flexible

Our test date options let you pick what will suit your schedule because your comfort is essential to us. Take the first step towards your sound insulation testing in Broad-Street by calling us now.

Test reports arrive the next day

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. We make certain all relevant issues are covered and quality tips are supplied by detailing all the aspects of the test in the report.

AF Acoustics sound testing services

We offer a wide range of thorough acoustic solutions for our clients nationwide, and we ensure a high calibre and effective approach. Contact us now for more information on how we can assist you with your acoustics requirements.

Impact and airborne floor test

These are only carried out on separating floor/ceiling between dwellings. The measurement of the extent of noise transmitted directly through impact from one adjoining room to another is known as impact testing. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

Approved Document E test

Document E of Building Regulations requires certain criteria for the sound performance of a dwelling. Our sound insulation tests are conducted in accordance to these criteria. For new buildings, results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. Converted structures expected impact sound results increases by 2dB L’nTw while the airborne sound results reduces by 2dB DnTw+Ctr.

Sound testing

With our professional and highly skilled expertise, we are willing to work with our clients to help them get a pass certificate in every situation. A new dwelling may have to undergo an airborne and impact test to meet the benchmark of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Contact us today for more information about our sound testing services or to book a no obligation quote, free of charge.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 testing of acoustic design in schools

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. If building a new school in Broad-Street, we can test the school to check if it meets the requirements of BB93.

Acoustic plan details

AF Acoustics provide detailed acoustic design services and consulting on a wide range of buildings. We have the capability and experience to develop customised solutions, and have a strong working knowledge of available proprietary acoustic products. We will develop detailed design solutions suitable for the specific demands of the project.

It is critical to get right professional assistance ahead of schedule from a highly qualified acoustic specialist. AF Acoustics can assist you with identifying the right acoustic propertiesfor your project at very early on in the construction process and tell you the best way to get them, utilizing a deep know-how of acoustic design.

We can help with:

Acoustic detail design for architects engaged with residential improvements in consistence with Part E Building Regulations, BS8233 and so on. Detail plans for the educational, commercial and healthcare industry so as to meet with the current criteria. Specifications and design details that enable good sound insulation and reduction of noise in residences. Public address and sound reinforcement (conference rooms / lecture theatres etc.)

Contact our professionals for a sound test quotation

AF Acoustics is a leading acoustic consultancy. It provides the following services: architectural and building acoustics, acoustics design, survey and investigation in the field of planning and noise, and examining and controlling air vibrations while conducting air leakage tests. Our professional guidance and advice is provided to private individuals, businesses and government agencies amongst others. You can contact us by sending us an email on info@af-acoustics.com or calling us for a free quote.

020 3372 4430 Contact us

Provide us with the following data

When contacting us for sound insulation testing quote, we will need you to provide the following information

Location of development

Where is your property located in Broad-Street?

Number of dwellings in the structure

Tell us how many dwellings you have in the property.

How many storeys are there?

To give you an appropriate quotation, would like to know the number of floors in your building.

Number of dwelling units per storey

To get an appropriate quotation and determine the kind of tests to be conducted, we will also need this.

Kind of property

Tell us the kind of property because different buildings require different amounts of tests.

New property or reconstructed dwelling

Newly completed constructions and refurbished structures have different requirements for sound insulation testing. This is why it’s important to provide this information beforehand. Our quotation is available at any time.

Building regulations for sound insulation test

Our sound insulation tests are conducted in accordance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building requirements. You can also get credits for Code for Sustainable Homes and EcoHomes environmental assessment projects.

Part E of building regulations resistance to the passage of sound (England and Wales)

Our certified engineers can come to your building whenever it might suit you to undertake sound insulation testing to Part E of Building Regulations adherence, recognised by Building Control.

Scotland Standard division for completed constructions

According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be taken at the completion of the building, using procedures given in annex 5.C. of the Scottish Standards. These standards don’t apply to detached structures that have access only for maintenance or are to used only by the occupants who live below.

How to pass a sound test

Make sure you pass your sound test by having efficient sound insulation included in the building design. It saves time and money and helps you avoid repair work and re-test expenses. We offer design services that help you construct separating walls and floors with good sound performance that meet ADE demands. The degree of guidance you require can vary, from site visits and comprehensive design reports, to simpler initial testing to know the starting point for construction. The are required in order to have good conditions to undertake the sound insulation tests: All windows and doors have been fitted and work Skirting boards are fixed Plug sockets, light switches and fittings are in place and working. Our accomplished acoustic consultants work with developers, planners, contractors, and architects of all sizes from the early stages of the building plan to help limit any potential sound insulation performance problems to the completion of the construction, guaranteeing that all properties meet the criteria of Building Regulations Document E 2003.

Analysis and Report Certificates

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern. A full report and individual sound test certificates can be generated and sent out usually the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The way the results look

Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. In the event of a wall or floor not achieving the Part E requirements, it may be necessary to carry out remedial works before having another sound test carried out. We can provide you with remedial design advice to help you achieve the Building Regulations requirements.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed