The measurement of the sound reduced by partitions in a development, such as a wall or floor, is known as sound insulation testing or sound testing. It assesses how good the soundproofing materials fixed to the property development are. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

As many contractors and developers have found to their detriment, without a sound insulation certificate, the Building Control Officer will not issue a completion certificate. We understand how important it is for you to get a sound insulation certificate. That’s why we go the extra mile to make sure you get your certificate as quickly as possible. In fact, we pride ourselves on issuing our sound insulation testing certificates as quickly as possible.

Even before you get the certificate, you will receive the results of the test. First, our skilled and competent sound insulation test will engineers give you a verbal result at the site. Then, a written report is sent to you within 24 hours of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Test?

Walls and floors that separate dwellings in a building are expected to be sound tested, as mandated by Document E of Building Regulations. Only dwellings that have used Robust Details, which licensed before the installation, are exempted from the test. Sound testing measures the impact and airborne sound moving through new and old adjoining buildings. This tests include the boundary walls between buildings and in-between the spaces in a development.

What is part of a Sound Insulation Test

Even though sound insulation testing equipment produces lots of noise, sound testing requires quiet conditions and dwellings. Because of this, workers on the site would have to leave during the time of the test, to avoid errors in the test calculation. The process of a sound test is determined by the size and complexity of the site being tested. A structure that is simple and the conventional size will usually take 90 minutes to be tested.

The sound testing engineers then proceed to give verbal results on the site and offer helpful advice on any problem areas noticed during the duration of the test.

The entire report and individual sound test certificate will be sent to you the day after. The way a sound test is conducted is determined by ADE of Building Regulations. It mandates that in all developments, every 10 units in a group or sub-group will undertake one set of tests. It explicitly states what a sub-group is in Section 1. Buildings to be tested are categorised into three kinds: houses, flats and rooms like care homes, student accommodation and hotel rooms. The extent of testing required for these three groups is shown below.

Why Should Your Dwelling Undergo Sound Testing

After the 2003, Approved Document E mandates that all new structures in UK must take a sound insulation test before completion. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. This Approved Document, as part of UK Building Regulations helps to ensure that new buildings are constructed to minimum standards that provide reasonable resistance to sound from other parts of the same building and from adjacent buildings. Testing for sound insulation is vital because sound influences how we live in the office, while relaxing or in the house. Restricting the sound that moves between floors and walls could result in a more relaxed and better surrounding.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. Let’s take a look at this scenario. An individual living in a block of flats might spend the weekend with friends relaxing and playing loud music. If the sound insulation on adjoining walls and floor is insufficient, the music will be distressful to neighbours, especially if they work at night. Sound insulation impacts people’s lives in various ways. It can be useful in dwellings with neighbouring units/flats/rooms which have diverse purposes, by guaranteeing that an occupant in a room will hear as little noise as possible from the neighbouring room.

How Do I Know if I Need a Sound Test?

You need a sound insulation test if you’re:

  • Constructing a nursing home or residential rooms like hostel or hotel rooms,
  • Converting a building with a single dwelling into flats,
  • Constructing a property with two or more units,
  • Using designs without Robust Details to build

Building Regulations Part E discusses sound testing in detail and has made it a requirement.

There are 2 ways you can comply. Test for sound insulation using the method of Approved Document E or use Robust Details in your development. If you choose the latter, you must use Robust Details which are a approved design details for partitioning walls and floors. You also cannot expand or tweak the design from the Robust Detail Approved listing. However, you are exempt from the sound test. Sound testing provides more flexibility by allowing different designs and is often therefore more cost effective in many ways compared to the Robust Details Scheme. Conducting on-site pre-completion sound testing also enables the architects more scope with their design and can lead to improved sound insulation performance.

How much does sound insulation testing cost?

Call us or email us to get a free quotation for your building. Our prices are extremely competitive and we’ve worked on developments of various sizes and types. You’re also assured of a quick turnaround time for your sound insulation test report and certificates.

Sound Insulation Test Time

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. During the test, you should provide the following:

  • Access to all rooms. The only exception is if a schedule was created before the test time.
  • 240V power supply
  • A noiseless site

How is sound insulation testing carried out?

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. The boundary floors and walls get airborne tests. Floors get an additional impact test.

The airborne sound insulation test is carried out with a large speaker or dodecahedron speaker, using a white or pink noise generator to create the source sound, almost always in the largest room of the two rooms under testing. A sound level meter calculates the noise in the source room and receiver room. Background sound is also calculated. Noise in the receiver room should be 10dB more than the background noise at all frequency measurements, so source noise is set to be greater than background noise. For airborne tests, two speakers positions are used in the source room and the level of noise entering into the receiving partition room is measured. That way the difference in sound level is calculated.

The variations or differences in noise level are ‘corrected’ to take into consideration the already present background noise in the receiving room and the reverberation time – measure of time needed for a sound to decay or be absorbed in a closed room by 60dB. A tapping machine is placed on the floor to execute an impact sound insulation test. The room under it is then measured for the noise levels. Once the calculations are completed and the result is achieved, it is compared with Building Regulations Part E standards. Of course, this is a simple way of describing the procedure followed when a sound test is carried out, but it enables you to understand it better.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. An airborne test calculates the amount of sound moving through a separating element. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. Sound level meter is also used for impact tests. Alongside it, a tapping machine that drops metal hammers is used. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. Test findings are compiled in a report and issued to the client. The report will be accepted by Building Control and used for signing off your project.

A sound test is mandatory for these buildings:

The airborne and impact sound going through new and old buildings are evaluated by sound testing. This can impact adjoining walls and floors between the building.

A new building with 2 or more dwellings

This ensures that a sound insulation system installed in residences meets the requirements of ADE.

Redevelopment of a building with a single dwelling into flats

The development that has been converted must conform to Building Regulations sound requirements.

Designed in a way that does not adhere to Robust Details

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the building design is slightly different from Robust Details, a sound test is essential so that Building Regulations criteria can be met. The minimum criterion is based on various factors such as the purpose of the development and if it is a permanent dwelling or rooms to be used as residences like students’ accommodations and hotels.

Parts of the UK AF Acoustics Cover

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Brownswood-Park. Af Acoustics work with individuals, government agencies, planning and environmental consultancies, and architects. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.

Why you should choose AF Acoustics

Our sound insulation testing expertise at AF Acoustics have aided several home and business owners in Brownswood-Park. We come highly recommended by our clients because of the guarantees when you work with us

15 years’ experience

We understand the industries our clients are in. Therefore, we provide advice that is technically adequate, useful and applicable. We also have a track record of providing superior acoustic services to our customers (home and business owners) in the UK in small and large projects, giving them astounding value for their money.

Competitive prices

Compared to other sound insulation testing service in Brownswood-Park, our prices are extremely competitive. This is because we want you to be able to afford the best expert sound testing service there is. To get a free quote for your dwelling, contact us today.

Prompt and productive consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Adaptable test dates

Your convenience is also important to us. This is why we offer you flexible options that let you pick test dates that are most convenient for you. Call us to get your sound testing in Brownswood-Park undertaken.

Next day reporting

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. The conveyed report will be exhaustive, covering every issue point by point to guarantee that the best suggestions are given.

Sound insulation services we provide

We offer a wide range of thorough acoustic solutions for our clients nationwide, and we ensure a high calibre and effective approach. Telephone or email us today for more data on how we can assist you with your acoustic requirements.

Impact and Airborne floor test

These are taken on separating floors/ceilings between residences. The calculation of the sound level transferred from one unit to another through a separating floor via impact is called an impact test. Airborne and impact tests are conducted on the floor partitions between liveable rooms.

ADE testing

Document E of Building Regulations requires certain criteria for the sound performance of a dwelling. Our sound insulation tests are conducted in accordance to these criteria. For new buildings, results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. Converted structures expected impact sound results increases by 2dB L’nTw while the airborne sound results reduces by 2dB DnTw+Ctr.

Sound test

Our services and expertise is unbeatable and we are glad to work with our clients to help pass their sound insulation tests. To make sure a new residence meets with the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw, an airborne wall test and an airborne and impact floor test will need to be conducted. We routinely give advice to developers and project managers from the beginning of the project, guaranteeing certainty when the time for a sound test is at hand. Simply contact us immediately ad you’ll get a free quotation in addition to more details about our sound testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) explains minimum performance standards for the acoustics of school buildings. It also describes the normal means of demonstrating compliance with the Building Regulations. If you’re constructing a new school in Brownswood-Park, we can test the sound performance to evaluate if it meets the standards of BB93.

Acoustic Design

We provide acoustic layout services and consultancy for a huge range of building types and sizes. Our experience and expertise enables us to create bespoke solutions and understand diverse acoustic products. As a result, we’re able to provide targeted solutions to the demands of the project.

As anyone who has had to deal with the acoustic properties of a building will know, it’s important to get the correct advice, as early as possible from a good acoustic consultant. AF Acoustics can help you to identify the correct acoustic requirements for your project at an early stage and advise on the best means to meet them using expert knowledge of acoustic design.

We can help with:

Acoustic detail design for architects engaged with residential improvements in consistence with Part E Building Regulations, BS8233 and so on. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Specifications and design details that enable good sound insulation and reduction of noise in residences. Improving sound and public address system in halls, conference rooms etc.

To get a sound test quote for your building, call or email our highly skilled professionals

AF Acoustics is a leading acoustic consultancy. It provides the following services: architectural and building acoustics, acoustics design, survey and investigation in the field of planning and noise, and examining and controlling air vibrations while conducting air leakage tests. Our expert consultation is available to individuals and companies with all types and sizes of constructions. We will give you free quotation with highly competitive rates. Simply call us or email info@af-acoustics.com

020 3372 4430 Contact us

Provide us with the following data

In your email or during your phone call, tell us about the following

The development’s location

Where in Brownswood-Park the property is situated

Total number of dwellings

What is the number of units in the development?

How many storeys are there?

For an accurate calculation of the quote, tell us the number of storeys

Number of dwelling units per storey

To get an appropriate quotation and determine the kind of tests to be conducted, we will also need this.

Kind of structure

Tell us the kind of property because different buildings require different amounts of tests.

New Build or conversion project

Newly completed constructions and refurbished structures have different requirements for sound insulation testing. This is why it’s important to provide this information beforehand. Our quotation is available at any time.

Building regulations for sound insulation test

We provide sound testing and sound insulation testing on all types of buildings, for compliance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building Standards. Testing can also gain credits for Code for Sustainable Homes and EcoHomes environmental assessment schemes.

Part E of building regulations resistance to the passage of sound (England and Wales)

Our certified engineers can come to your building whenever it might suit you to undertake sound insulation testing to Part E of Building Regulations adherence, recognised by Building Control.

Scotland Standard division for completed constructions

According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Fully detached roofs or walkways that are not used for residential purposes do not have to take the sound tests of the Scottish Standards 5.1.

How Do I Pass a Sound Insulation Test?

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. If you are unsure of how to build the separating floor and wall constructions and associated junctions across your development to satisfy the requirements of Document E 2003, we can offer design advice. Whether you want some initial tests on your project, or comprehensive reports at the end, we can help you at the level that you need. The following will give you a better chance of passing the sound test: Install and make sure that all external and internal doors and windows are operational Fit and seal skirting boards Light switches, plug sockets, and light fittings are adequately fixed. Our professional acoustic professionals work with contractors, architects, developers, and planner from the beginning of the design to make sure that all requirements are met.

Certificates for test evaluation and report

After the test, AF Acoustics’ competent and well trained engineers can let you know the verbal results of your sound test and provide feedback on issues noticed during the test. We endeavour to send an investigation and report certificate the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What the results look like

A sound insulation certificate will be sent to you whether the property has a good sound performance in accordance with ADE or not. In the event of a wall or floor not achieving the Part E requirements, it may be necessary to carry out remedial works before having another sound test carried out. We can provide you with remedial design advice to help you achieve the Building Regulations requirements.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed