Sound insulation testing is used to measure the resistance of sound provided by an element of a building (such as a floor or wall) between dwellings. It essentially measures the effectiveness of the sound proofing treatment installed as part of a build or property development. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

Building Control does not issue completion certificates to buildings that don’t have a sound insulation certificate. Contractors and developers have sometimes discovered this, to their detriment. We understand how important it is for you to get a sound insulation certificate. That’s why we go the extra mile to make sure you get your certificate as quickly as possible. In fact, we pride ourselves on issuing our sound insulation testing certificates as quickly as possible.

AF Acoustics’ competent and well-trained engineers, who will be available for testing, can even let you know the verbal results of your sound test. You will receive a written report in the space of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Insulation Test?

Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. Sound testing measures the impact and airborne sound moving through new and old adjoining buildings. This tests include the boundary walls between buildings and in-between the spaces in a development.

What is involved in a Sound Test

The sound test itself produces very high levels of noise but also requires relatively quiet conditions on site. For these reasons, any workforce in the testing area will have to leave temporarily to ensure test accuracy. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. A dwelling or development of normal size and simplicity will more than likely be tested in 90 minutes.

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern.

A full and thorough report with the certificate of the test will be given to you within 24 working hours. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. Find below the testing stipulation for each kind of development.

Why is Sound Insulation Testing Relevant?

Sound insulation testing is required because ADE of Building Regulations has made it compulsory for all new buildings to take a sound test prior to finishing construction. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. The aim of Approved Documet E of the Building Regulations is to establish a minimum standard for the reduction in noise levels between all dwellings in a new or refurbished building. Sound insulation testing is important because sound affects the way we live, whether at work, in the home or whilst at leisure. Noise reduction between walls and floors could result in a more comfortable, productive environment.

Sound insulation and speech privacy are important because not having them results in an unfavourable environment for those living in the development. For instance, in an apartment building, the neighbour upstairs might invite friends over during the weekend and put on loud music. The inhabitant downstairs might spend night hours as work time. If the sound insulation is inefficient, this could lead to lots of problems. Sound insulation impacts people’s lives in various ways. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

Do You Need a Sound Test?

You need sound insulation testing if you:

  • Build a new development of 2 or more dwellings / flats
  • Convert a former single dwelling into flats
  • Build a Nursing Home or rooms for residential use, i.e. hotel or hostel
  • Have designs which do not adhere to Robust Details

Sound insulation is covered and made mandatory under Approved Document E of The Building Regulations.

There are two ways in which to show compliance. You can either test to the regime set out in Approved Document E (ADE), or pay to use Robust Details. Robust Details are design details for separating elements, which have been tested before to comply with Document E standards. You also cannot expand or tweak the design from the Robust Detail Approved listing. However, you are exempt from the sound test. This becomes difficult when you need to pick a more appropriate or cost-effective design that will suit your needs. Sound tests enable you do that, making it more flexible. Conducting on-site pre-completion sound testing also enables the architects more scope with their design and can lead to improved sound insulation performance.

Price for Sound Insulation Testing

Contact us and we’ll give you a free quote on the sound test cost based on the requirements of your building. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

Period Sound Insulation Test Should be Carried Out

The ideal period for a sound insulation test is after the fitting of windows and doors, and before the building is finished. If you want, AF Acoustics can conduct tests before then to find out if there are any problems on your property. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

How a Sound Test is Done

Sound testing procedure is quite simple and our engineers are happy to explain this on site. For partition walls, airborne tests are carried out. For floors there are two types, airborne and impact tests.

A big or multidirectional speaker, with a generator of pink or white noise is used to the biggest room. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. The background noise level is also measured. The higher the background noise then the higher the source noise will need to be set, since the resulting noise level in the receiver room needs to be 10dB higher than the background noise at all measured frequencies. For airborne tests, two speakers positions are used in the source room and the level of noise entering into the receiving partition room is measured. That way the difference in sound level is calculated.

This basic level difference is then ‘corrected’ to allow for the reverberation time (the time is taken, in seconds, for a noise source to decay by 60dB) and the existing levels of background noise monitored whilst in the receiving room. A tapping machine is placed on the floor to execute an impact sound insulation test. Noise level in the room below is measured at various different frequencies. Once the calculations are completed and the result is achieved, it is compared with Building Regulations Part E standards. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. Airborne sound test is the measurement of sound moving through the air through a wall or floor. Equipment used for the test include a noise generator, speakers and sound level meter. For impact sound testing, the equipment used is a tapping machine that uses dropping hammers to create noise and a sound level meter. The tests are administered in room with residential purposes. For example, kitchens/living spaces, lounges, bedrooms and living rooms. Test findings are compiled in a report and issued to the client. The report will be accepted by Building Control and used for signing off your project.

It’s important to undertake a sound test if you have this kind of building:

For sound testing we usually undertake impact and airborne sound test on buildings. This affects the separating floors and walls between habitable rooms of buildings and developments.

Property with two or more units

With the sound test, you can be certain that the property has a good acoustic performance.

Converting a single development to flats

The development that has been converted must conform to Building Regulations sound requirements.

Designed in a way that does not adhere to Robust Details

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. If the design does not completely follow Robust Details, sound insulation testing will occur to be certain the building meets ADE criteria. The minimum criterion is based on various factors such as the purpose of the development and if it is a permanent dwelling or rooms to be used as residences like students’ accommodations and hotels.

Towns in the UK AF Acoustics Services can be Found

AF Acoustics provides acoustic design services to customer nationwide, especially in Chadwell-Heath. Our clients include architects, planning and environmental consultancies. We also work with government agencies and private individuals. We’re based in several areas across the south east region of UK so that we can give you the most cost effective quote in the industry.

Why choose AF Acoustics for Sound Insulation Testing?

Our sound insulation testing expertise at AF Acoustics have aided several home and business owners in Chadwell-Heath. We come highly recommended by our clients because of the guarantees when you work with us

We’ve been conducting sound tests for more than 15 years

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. We have over 15 years of experience satisfying the acoustic needs of UK businesses and homeowners with a proven track record on both small scale and major projects. You can always rely on us for exceptional value for money.

Best rates available

We want to ensure that you get the best value for your money. That is why we have one of the most unbeatable rates in and outside Chadwell-Heath. Call us or email today to get a free quotation.

Consultancy that is effective and efficient

We will listen to your wishes, provide you sturdy solutions and deliver acoustic consultancy through our expertise. When you reach out to us for professional advice, we make certain that we render accurate solutions rapidly. We suggest productive answers that handle your present and long-term desires to the maximum.

Adaptable test dates

Our test date options let you pick what will suit your schedule because your comfort is essential to us. Call us now to schedule sound insulation testing in Chadwell-Heath

You get your report the next day

The sooner you get a report on the completed sound insulation test, the sooner you can take appropriate action. We strive to deliver next day reporting in all scenarios regardless of the complexity or size of the project. We make certain all relevant issues are covered and quality tips are supplied by detailing all the aspects of the test in the report.

Sound insulation testing services AF Acoustics undertake

AF Acoustics offer a range of comprehensive acoustic solutions to customers nationwide, and we guarantee a high-quality and high-efficiency approach. To find out more about we can help you with your acoustics needs, call or email us right away.

Impact and airborne tests for floors

These are performed on floors and/or ceilings between units. An impact test examines the level of noise moving from one dwelling to another through impact on adjoining floors/ceilings. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

ADE testing

Document E of Building Regulations requires certain criteria for the sound performance of a dwelling. Our sound insulation tests are conducted in accordance to these criteria. The impact sound test of new dwellings should be 62dB L’nTw or less and airborne sound insulation 45dB DnTw+Ctr or more while impact results for reconstructed properties should be 64dB L’nTw and airborne sound insulation 43dB DnTw+Ctr or more.

Sound insulation test

We offer the highest levels of service and expertise and are always happy to work with you to give you the best possible chance of achieving a pass certificate. In new properties, an airborne and impact test will help you guarantee the building meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. When working with AF Acoustics, developers and project managers get acoustic advice right from the start of the building project. That way, they can make sure their developments have a good sound performance. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 testing of acoustic design in schools

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. Are you building a new school in Chadwell-Heath? Contact us to arrange a sound test and make sure it meets the benchmarks of BB93.

Acoustic design details

We provide acoustic layout services and consultancy for a huge range of building types and sizes. Our experience and expertise enables us to create bespoke solutions and understand diverse acoustic products. As a result, we’re able to provide targeted solutions to the demands of the project.

When constructing a building, it’s vital you get advice from the right acoustic consultant on time. AF Acoustics uses professional expertise to discover your acoustic needs early on and proffer ideas on how to meet them.

We will help you with:

Acoustic detail design for architects engaged with residential improvements in consistence with Part E Building Regulations, BS8233 and so on. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Specification and design of building services for noise control in residential and other noise sensitive scenarios Improving sound and public address system in halls, conference rooms etc.

Contact our professionals for a sound test quotation

At AF Acoustics, we are an independent acoustic consultancy. Our work embraces acoustic surveys, acoustic design and investigation work in the fields of planning and noise, architectural and building acoustics, the monitoring and control of vibrations and air tightness testing. Our professional guidance and advice is provided to private individuals, businesses and government agencies amongst others. You can contact us by sending us an email on info@af-acoustics.com or calling us for a free quote.

020 3372 4430 Contact us

Provide us with the following data

When contacting us for sound insulation testing quote, we will need you to provide the following information

Location of property

Where is your property located in Chadwell-Heath?

Total number of dwellings

Number of dwellings on the property

How many storeys are there?

For the right calculation of your quotation, tell us how many levels are in your building.

Dwellings configuration per floor

This will also be needed to determine scope of the testing and provide an accurate quote

Types of construction

The type of building, as different building types typically require a different testing.

New construction or refurbished building

These two go require different types performance, so let us know which one it is and you’ll get an accurate test and quotation.

Building regulations for sound insulation test

We provide sound testing and sound insulation testing on all types of buildings, for compliance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building Standards. Testing can also gain credits for Code for Sustainable Homes and EcoHomes environmental assessment schemes.

Part E of building regulations resistance to the passage of sound (England and Wales)

We can have fully accredited engineers sent to your property at your convenience to provide certification for Building Regulations Part E compliance, recognised by Building Control.

Standard division for structures (Scotland)

Section 5.1 of the Scottish Building Standards explicitly describes expected energy performance of dwellings. It states, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be taken at the completion of the building, using procedures given in annex 5.C. of the Scottish Standards. These standards don’t apply to detached structures that have access only for maintenance or are to used only by the occupants who live below.

How Do I Pass a Sound Insulation Test?

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. Are you uncertain that the separating floor and walls you will build will adhere to Document E 2003 conditions? You can book our design services. Whether you want some initial tests on your project, or comprehensive reports at the end, we can help you at the level that you need. The following criteria should be followed to provide you with the best chance of passing your sound test: Install and make sure that all external and internal doors and windows are operational Skirting boards are fixed are sealed Light fittings and switches and plug sockets are fitted and working. Our expert acoustic consultants work with planners, developers, architects and contractors from the beginning of the design stage till when the property is finished to ensure it meets the conditions of Document E 2003.

Test and report certificates

After the test, AF Acoustics’ competent and well trained engineers can let you know the verbal results of your sound test and provide feedback on issues noticed during the test. We endeavour to send an investigation and report certificate the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The results

Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. In the event of a wall or floor not achieving the Part E requirements, it may be necessary to carry out remedial works before having another sound test carried out. We can provide you with remedial design advice to help you achieve the Building Regulations requirements.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed