Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. New structures and reconstructed developments have been mandated by the Building Regulations to test for sound upon completion, since Approved Document E (ADE) was reappraised in 2003.

As many contractors and developers have found to their detriment, without a sound insulation certificate, the Building Control Officer will not issue a completion certificate. As a result of this, we try to ensure that you are issued with a sound insulation certificate as fast as possible. We pride ourselves on the facts that our sound insulation certificates are issued with speed and efficiency.

Our highly qualified site engineers can arrive on site when needed. They will provide verbal results after the test and a written report will be sent to you within 24 working hours.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Testing Does

Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. Sound Insulation Testing tests for both the airborne sound and the impact sound which travels through new or existing buildings . The tests cover party walls and floors between new and existing buildings, or between spaces within a new development entirely.

The Procedures Involved in a Sound Insulation Test

While producing lots of noise, sound test needs a quiet site to be conducted efficiently. Due to this fact, the workers in the site should not be present at the time of the test. Undertaking sound tests on site varies according to the size and complexity of the building project and the site conditions. A dwelling or development of normal size and simplicity will more than likely be tested in 90 minutes.

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. The sound insulation testing methodology has been outlined by Document E of the Building Regulations. The document states that every 10 units in a sub-group or group should undergo one set of test, and defines a sub-group in Section 1. Buildings are divided into three kinds for the test – houses, flats and rooms built for or converted to residential dwellings, like student accommodation, care homes and hotel rooms. The extent of testing required for these three groups is shown below.

Why Sound Testing is Required

After the 2003, Approved Document E mandates that all new structures in UK must take a sound insulation test before completion. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. This Approved Document, as part of UK Building Regulations helps to ensure that new buildings are constructed to minimum standards that provide reasonable resistance to sound from other parts of the same building and from adjacent buildings. Testing for sound insulation is vital because sound influences how we live in the office, while relaxing or in the house. Restricting the sound that moves between floors and walls could result in a more relaxed and better surrounding.

Sound insulation and speech privacy are critical for a variety of reasons. Inadequate sound insulation can be extremely distressing to those affected by it. For instance, in an apartment building, the neighbour upstairs might invite friends over during the weekend and put on loud music. The inhabitant downstairs might spend night hours as work time. If the sound insulation is inefficient, this could lead to lots of problems. This is just one instance of the influence of sound insulation on our lives. Then there are developments where each neighbouring room / flat / unit has mixed uses. If the development has passed the sound insulation test, noise is reduced to a minimum.

How Do I Know if I Need a Sound Test?

Are you converting your property into several units? Does your design not use Robust Details? Are you constructing a new building with more than two rooms? Are you building a nursing home or rooms that will used for residential purposes, like hotels and hostels? If so, your structure needs to undergo a sound test. Sound insulation is covered and made mandatory under Approved Document E of The Building Regulations.

Either you follow the pre-completion sound testing process stipulated therein or you use Robust Details. This way, you have conformed to the requirements. Robust Details are design details for separating elements, which have been tested before to comply with Document E standards. When you use it, you don’t have to take a sound insulation test. However, you must abide strictly by the design from the Robust Details approved list. Being able to adapt your design to suit your needs is more efficient and costs less in the long run. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.

Price for Sound Insulation Testing

Call us or email us to get a free quotation for your building. We have worked throughout the country on all sizes of project, and should a sound insulation report and certificates be required, we can provide the fastest turnaround times and most competitive prices available. If you get a better quote elsewhere, simply forward it to us and we will try and beat it!

When Should the Sound Tests be done?

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. For your sound tests to be conducted successfully we need the property to be quiet, with workers not near the rooms to be tested during the test time (a noisy environment makes the test difficult and sometimes unsuccessful). We also need access to all units unless the test program has been compiled earlier. Finally, we need 240V power supply.

How is Sound Insulation Testing Done?

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. The boundary floors and walls get airborne tests. Floors get an additional impact test.

A big or multidirectional speaker, with a generator of pink or white noise is used to the biggest room. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. Airborne sound testing is done in a similar way. First, two speaker positions are used for each source room. Then, the level of sound in the receiver room is measured so that the difference in noise level between the two rooms can be calculated.

The variations or differences in noise level are ‘corrected’ to take into consideration the already present background noise in the receiving room and the reverberation time – measure of time needed for a sound to decay or be absorbed in a closed room by 60dB. Impact tests are carried out by means of a tapping machine placed on the floor to be measured. Noise level in the room below is measured at various different frequencies. Calculations are undertaken, and results achieved. The results are crosschecked to ensure they meet Document E of Building Regulations target. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. An airborne test is used to check how much sound is moving through the air between partitions. The equipment we use are a sound level meter, loudspeaker and white or pink noise generator. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. Testing can only be completed on ‘habitable’ rooms. Habitable rooms can be bedrooms, lounges, living rooms and open plan kitchen/ living spaces. The outcome of the test is written in a report and sent to the customer. This report helps Building Control sign off your building.

Sound Insulation Testing is necessary for these types of builds:

Sound insulation tests examine airborne and impact sound moving through buildings. It is usually undertaken between party walls and floors between buildings or between spaces within a new development.

A new building with not less than two rooms

This makes certain that the dwellings have adequate sound proofing.

A single dwelling that was turned into a development with several flats or units

When the development is completed, ADE of Building Regulations should be checked, and sound insulation tested accordingly.

Design that don’t have Robust Details factored in

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the building design does not strictly adhere to Robust Details, a sound insulation test becomes necessary to meet Building Regulations. A building built as a permanent dwelling has different minimum standards from a building with rooms built for residential purpose, like a hotel or a hostel.

Which areas of the UK does AF Acoustics cover?

AF Acoustics provides acoustic design services to customer nationwide, especially in Cockfosters. Our clientele also include government agencies, architects, and organisations involved in planning and environmental consultancy. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.

Why you should pick AF Acoustics for your sound testing

Having rendered high quality service to numerous customers in Cockfosters, we have gotten great positive feedback and recommendation from our clientele due to the following:

15 years’ experience

We understand the industries our clients are in. Therefore, we provide advice that is technically adequate, useful and applicable. We also have a track record of providing superior acoustic services to our customers (home and business owners) in the UK in small and large projects, giving them astounding value for their money.

Best rates available

Compared to other sound insulation testing service in Cockfosters, our prices are extremely competitive. This is because we want you to be able to afford the best expert sound testing service there is. To get a free quote for your dwelling, contact us today.

Fast and efficient consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Adaptable test dates

Your convenience is also important to us. This is why we offer you flexible options that let you pick test dates that are most convenient for you. Call us now to schedule sound insulation testing in Cockfosters

Get your test reports quickly

The sooner you get a report on the completed sound insulation test, the sooner you can take appropriate action. We strive to deliver next day reporting in all scenarios regardless of the complexity or size of the project. The delivered report will be comprehensive and well detailed to ensure all relevant issues are covered and any recommendations are provided.

Sound insulation services we provide

AF Acoustics offer a variety of complete acoustic slutions to clients all over the Uk, To find out more about we can help you with your acoustics needs, call or email us right away.

Impact and Airborne floor test

These are only carried out on separating floor/ceiling between dwellings. The measurement of the extent of noise transmitted directly through impact from one adjoining room to another is known as impact testing. These floors in habitable rooms of flats undergo both impact and airborne tests.

Testing in line with Part E of Building Regulations

Document E of Building Regulations requires certain criteria for the sound performance of a dwelling. Our sound insulation tests are conducted in accordance to these criteria. For new buildings, results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. Converted structures expected impact sound results increases by 2dB L’nTw while the airborne sound results reduces by 2dB DnTw+Ctr.

Sound insulation test

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. In new properties, an airborne and impact test will help you guarantee the building meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Simply contact us immediately ad you’ll get a free quotation in addition to more details about our sound testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 testing of acoustic design in schools

Building Bulletin 93 (BB93) describes the minimum requirement for the acoustics of a school building. It also stipulates how a school can conform to Building Regulations. Are you building a new school in Cockfosters? Contact us to arrange a sound test and make sure it meets the benchmarks of BB93.

Acoustic layout

AF Acoustics provide extensive design services and consultancy on a variety of buildings. We have the ability and experience to create bespoke solutions, and have solid working information of accessible acoustic items. We will create design solutions appropriate for the explicit requests of the construction.

As anyone who has had to deal with the acoustic properties of a building will know, it’s important to get the correct advice, as early as possible from a good acoustic consultant. AF Acoustics can help you to identify the correct acoustic requirements for your project at an early stage and advise on the best means to meet them using expert knowledge of acoustic design.

We are able to help with:

Acoustic detail layout for architect developing structures complying to Building regulations, BS8233 and so on. Detail designs for the health, educational and commercial projects in order to meet up with the necessary requirements. Specifications and building services design for control of noise in noise sensitive areas. Public address and sound reinforcement (conference rooms / lecture theatres etc.)

Contact our professionals for a sound test quotation

At AF Acoustics, we are an independent acoustic consultancy. Our work embraces acoustic surveys, acoustic design and investigation work in the fields of planning and noise, architectural and building acoustics, the monitoring and control of vibrations and air tightness testing. We want to give you expert guidance and provide working solutions, whether you are an individual or an organisation. For a quotation, call or email info@af-acoustics.com

020 3372 4430 Contact us

Giving the following information to us will be helpful

In your email or during your phone call, tell us about the following

Location of development

Where in Cockfosters the property is situated

Total number of dwellings

Number of dwellings on the property

How many storeys are there?

For the right calculation of your quotation, tell us how many levels are in your building.

Number of dwelling units per storey

This will also be needed to determine scope of the testing and provide an accurate quote

Kind of structure

What is your building type? This will help us know the kind of test it will undergo.

New property or reconstructed dwelling

The testing requirements for new dwellings and converted properties are not the same. Tell us the type of building you have so that we give you the right quote.

Building regulations for sound insulation test

We provide sound testing and sound insulation testing on all types of buildings, for compliance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building Standards. Testing can also gain credits for Code for Sustainable Homes and EcoHomes environmental assessment schemes.

Resistance to the passage of sound: Approved Document E (England and Wales)

Our certified engineers can come to your building whenever it might suit you to undertake sound insulation testing to Part E of Building Regulations adherence, recognised by Building Control.

Building Standards Division (Scotland)

Section 5.1 of the Scottish Building Standards stipulates that “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be taken at the completion of the building, using procedures given in annex 5.C. of the Scottish Standards. These standards don’t apply to detached structures that have access only for maintenance or are to used only by the occupants who live below.

Passing a sound insulation test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. If you are unsure of how to build the separating floor and wall constructions and associated junctions across your development to satisfy the requirements of Document E 2003, we can offer design advice. Our consultation process is led by your project requirements and may include assessment of design reports, test of the development and multiple site visits. The following criteria should be followed to provide you with the best chance of passing your sound test: All windows and door have been fixed and are functioning Skirting boards are fitted Fix all light switches, light fittings and plug sockets. We work with several professionals in construction from the beginning of the design stage to the completion of the development to make certain it conforms to Document E 2003 of Building Regulations.

Analysis and Report Certificates

To get details of the results of a completed sound insulation test, we will provide you with an analysis and report certificate. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

How the results are

Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. If parts or all the building fails the test, repair work and a retest is recommended. We provide design advice to ensure your property does proper remedial and meets up with the necessary requirements.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed