The measurement of the sound reduced by partitions in a development, such as a wall or floor, is known as sound insulation testing or sound testing. It assesses how good the soundproofing materials fixed to the property development are. New structures and reconstructed developments have been mandated by the Building Regulations to test for sound upon completion, since Approved Document E (ADE) was reappraised in 2003.

Building Control does not issue completion certificates to buildings that don’t have a sound insulation certificate. Contractors and developers have sometimes discovered this, to their detriment. We know how important a sound insulation certificate is to you. That is why we work hard to make certain that you get the certificate quickly. In fact, we pride ourselves on issuing our sound insulation testing certificates as quickly as possible.

Our fully trained sound insulation test engineers can be on site when you need them. Your AF Acoustics engineer will give you immediate verbal results from the sound test, and you can will have a written report by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Test?

Walls and floors that separate dwellings in a building are expected to be sound tested, as mandated by Document E of Building Regulations. Only dwellings that have used Robust Details, which licensed before the installation, are exempted from the test. Sound insulation tests examine airborne and impact sound moving between separating walls and floors. The tests include party walls and floors between structures or between spaces within a new development.

What is involved in Sound Insulation Testing

While producing lots of noise, sound test needs a quiet site to be conducted efficiently. Due to this fact, the workers in the site should not be present at the time of the test. The way a sound test is administered depends on the size and type of building and the development’s condition. If the site is simple and of regular size, it typically takes about 90 minutes to complete the sound test.

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern.

The entire report and individual sound test certificate will be sent to you the day after. The sound testing guidelines are stipulated in Building Regulations ADE. It requires one set of test to be conducted on 10 units in a group or sub-group. You can find out what is meant by a sub-group in Section 1 of ADE. Buildings are divided into three kinds for the test – houses, flats and rooms built for or converted to residential dwellings, like student accommodation, care homes and hotel rooms. How much testing that should be done on each group is listed below:

Why Sound Testing is Required

After the 2003, Approved Document E mandates that all new structures in UK must take a sound insulation test before completion. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. ADE ensures that new building are resistant to noise from adjoining buildings and other rooms within the same building. Sound insulation testing is important because sound affects the way we live, whether at work, in the home or whilst at leisure. Noise reduction between walls and floors could result in a more comfortable, productive environment.

Sound insulation and having privacy while speaking are crucial for a number of reasons. When sound insulation is deficient, it can cause discomfort to occupants. It would mean noise moving from one flat to another in a block of flats. If, for example, an occupant works at night and happens to hear loud music from a neighbour upstairs on a weekend night, it would be very discomforting. Sound insulation helps improve the quality of a person’s life in diverse ways. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

Do I Need a Sound Insulation Test?

If you’re doing one of the following, then you need a sound test:

  • Constructing a building that has two or more units
  • Constructing a nursing home or rooms that will be lived in, e.g. hotel room or hostel
  • Converting a single development to flats
  • Using designs where Robust Details are not included

It is imperative that sound insulation tests be undertaken, as explained and stipulated by ADE.

There are 2 ways you can comply. Test for sound insulation using the method of Approved Document E or use Robust Details in your development. If you choose the latter, you must use Robust Details which are a approved design details for partitioning walls and floors. You also cannot expand or tweak the design from the Robust Detail Approved listing. However, you are exempt from the sound test. Being able to adapt your design to suit your needs is more efficient and costs less in the long run. Sound insulation testing can also help architects enhance their building design and in turn the sound insulation of the building.

Cost of Sound Insulation Testing

Simply contact us and we will be able to provide a free, no obligation quotation as to the requirements and costs for your development. We have handled all kinds of sound insulation projects in UK and issue a report and certificate as quickly as possible. Our prices are affordable too and can beat others.

Ideal Period for a Sound Insulation Test

The best time for a sound insulation test is just before the construction of the property is finished and after all windows and doors are fixed. However, in the case of a problem we can take the test before then. To be able to conduct sound insulation testing we require the provision of a 240V power supply, and a quiet site (a noisy site can make conducting the tests extremely difficult). Access will be required to all rooms of the development unless a test schedule is determined in advance.

How is sound insulation testing carried out?

The method of taking the test is not complex and our sound test engineers can explain it thoroughly on site, if you wish. For partition walls, airborne tests are carried out. For floors there are two types, airborne and impact tests.

The test uses a dodecahedron speaker and pink or white noise generator for source sound. The sound source is placed in the largest room of the two. A sound level meter calculates the noise in the source room and receiver room. The background noise level is also measured. The higher the background noise then the higher the source noise will need to be set, since the resulting noise level in the receiver room needs to be 10dB higher than the background noise at all measured frequencies. Airborne sound tests are conducted in this manner: two singular speaker positions are used for every source room. The noise in the receiver room is measured to determine the variations in noise level between the source and receiver room.

The variations or differences in noise level are ‘corrected’ to take into consideration the already present background noise in the receiving room and the reverberation time – measure of time needed for a sound to decay or be absorbed in a closed room by 60dB. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. The sound level in the room below it is recorded. Calculations are undertaken, and results achieved. The results are crosschecked to ensure they meet Document E of Building Regulations target. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. Airborne sound test is the measurement of sound moving through the air through a wall or floor. We use pink or white noise generator and speakers on one side of the partition. A sound level meter is used on calculating sound in both units. Sound level meter is also used for impact tests. Alongside it, a tapping machine that drops metal hammers is used. Testing is done on rooms that can be lived in. E.g. lounges, kitchens, bedrooms and living rooms. Test findings are fed into a report that will be sent to the client. This report will always be acceptable to Building Control and will help you to get your development signed off.

These kinds of properties should undergo a sound insulation test:

Sound insulation tests examine airborne and impact sound moving through buildings. It is usually undertaken between party walls and floors between buildings or between spaces within a new development.

Two or more new build dwellings or flats

This makes sure that the sound insulation for the building meets all the necessary requirements.

A single dwelling that was turned into a development with several flats or units

When the development is completed, ADE of Building Regulations should be checked, and sound insulation tested accordingly.

Designs without Robust Details

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. Once the design does not strictly abide by the design from Robust Detail approved list, the structure will have to undergo a sound test to ensure it conforms to Building Regulations. Minimum criterion differs based on the type and purpose of the development. A development with rooms intended as residences, like a hostel or hotel, won’t have the same criteria as a structure for permanent dwelling.

Areas in the UK AF Acoustics Conduct Test

AF Acoustics is an acoustic consultancy providing acoustic design services to clients nationwide, especially in Cottenham-Park. Af Acoustics work with individuals, government agencies, planning and environmental consultancies, and architects. You can find our consultants all over the south east region of the country. That way we give you the most affordable quotation that will meet your budget needs.

Why choose AF Acoustics for Sound Insulation Testing?

Our sound insulation testing expertise at AF Acoustics have aided several home and business owners in Cottenham-Park. We come highly recommended by our clients because of the guarantees when you work with us

Sound testing experience of over 15 years

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. Our clients in the UK are completely satisfied with our acoustic solutions. Irrespective of the type of project you have, minor or major, you can be assured that we’ll give outstanding value for your money.

Competitive prices

To make certain that all clients in Cottenham-Park can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Cottenham-Park. Contact us right now to get a quotation that’s completely free of charge.

Consultancy that is effective and efficient

We offer strong durable advice based on your problem and give highly knowledgeable acoustic advice. When you reach out to us for professional advice, we make certain that we render accurate solutions rapidly. We suggest productive answers that handle your present and long-term desires to the maximum.

Test dates that are flexible

Your convenience is essential to us. This is the reason we provide you with adaptable choices that allow you to pick test dates that are most advantageous for you. Call us to get your sound testing in Cottenham-Park undertaken.

You get your report the next day

When you get your sound test report fast, you’re able to take corrective action. We try to issue reports on the next working day no matter how large or complex the project. The report will be detailed and thorough so that all necessities are written out and any advice provided.

Sound insulation testing services AF Acoustics undertake

With AF Acoustics, you get a highly effective and expert acoustic advice which our customers all over UK have benefited from. Phone or email us today for more information on how we can help you with your acoustic requirements.

Airborne and impact ceilings/floor tests

These are only carried out on separating floor/ceiling between dwellings. An impact test examines the level of noise moving from one dwelling to another through impact on adjoining floors/ceilings. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

PART E Testing

Our sound insulation testing in accordance with Building Regulations Approved Document E, which sets out details pertaining to the resistance to the passage of sound. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw for new structures. Converted properties get a slightly different requirement. Expected minimum airborne sound insulation test result is 43dB DnTw+Ctr while expected maximum impact sound test result is 64dB L’nTw.

Sound insulation test

We offer the highest levels of service and expertise and are always happy to work with you to give you the best possible chance of achieving a pass certificate. In new build properties an airborne test or an airborne and impact test may be required to ensure it meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. To find out more about our sound testing services and get a free quotation, contact us now.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) describes the minimum requirement for the acoustics of a school building. It also stipulates how a school can conform to Building Regulations. Are you building a new school in Cottenham-Park? Contact us to arrange a sound test and make sure it meets the benchmarks of BB93.

Acoustic Design

AF Acoustics give definite design services and consultancy services to all types of developments. We create bespoke solution and can provide information on the best available acoustic products. We will tailor our design solutions to your project.

As anybody who has needed to handle the acoustics for a building will know, it’s essential to get proper advice, early in the project from a good acoustic expert. AF Acoustics can help you with identifying the right acoustic needs and standard for your construction at the beginning period and advise you on how to meet them.

We are able to assist with:

Acoustic detail layout for architect developing structures complying to Building regulations, BS8233 and so on. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Specifications and building services design for control of noise in noise sensitive areas. Public address and sound reinforcement (conference rooms / lecture theatres etc.)

To get a sound test quote for your building, call or email our highly skilled professionals

We are an independent acoustic organisation that handles everything concerning acoustics including survey, design, architectural and building acoustics and air tightness testing. Our expert consultation is available to individuals and companies with all types and sizes of constructions. We will give you free quotation with highly competitive rates. Simply call us or email info@af-acoustics.com

020 3372 4430 Contact us

We will need the following information:

Give us the following information when contacting us

Construction’s location

Where is your development situated in Cottenham-Park

Total number of dwellings

Total number of dwellings in the structure

How many storeys are there?

For an accurate calculation of the quote, tell us the number of storeys

Dwellings configuration per floor

To get an appropriate quotation and determine the kind of tests to be conducted, we will also need this.

Kind of structure

The type of building, as different building types typically require a different testing.

New dwelling or converted property

Knowing if your building is new or converted allows us to give you a competitive quotation and prepare the right test for it.

Building regulations for sound test

Our ADE compliant sound tests can help you gain credits for Code for Sustainable Homes and EcoHomes environmental assessment structures.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

Our expert engineers can issue certificates for the sound insulation testing. They can visit the site and conduct the test that will lead to getting a certificate which is in line with Building Regulations and Building Control requirements.

Standard division for structures (Scotland)

Section 5.1 of the Scottish Building Standards states “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Fully detached roofs or walkways that are not used for residential purposes do not have to take the sound tests of the Scottish Standards 5.1.

How to get a pass certificate for your sound test

The best method to guarantee you pass your sound test is to design the building with a view to good sound insulation performance. This shouldn’t be exorbitant, and can save time and cost at the end, without your having to correct sound problem or pay for a re-test. We offer design services to enable separating walls and floors with good sound insulation to meet the requirements of ADE, 2003. Whether you want some initial tests on your project, or comprehensive reports at the end, we can help you at the level that you need. Take the following action to give your building the best opportunity to pass the sound insulation test: Windows and internal and external doors are fitted and operable Skirting boards are fixed are sealed Plug sockets, light switches and fittings are in place and working. Our professional acoustic professionals work with contractors, architects, developers, and planner from the beginning of the design to make sure that all requirements are met.

Analysis and Report Certificates

To get details of the results of a completed sound insulation test, we will provide you with an analysis and report certificate. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

How the results are

You will get your sound insulation test certificate whether you pass or fail the sound tests. If parts or all the building fails the test, repair work and a retest is recommended. We provide design advice to ensure your property does proper remedial and meets up with the necessary requirements.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed