Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.
Not doing so is a costly venture for developers and contractors as Building Control will not give a completion certificate for developments that have not undergone the test. The significance of a sound insulation certificate cannot be overrated. Therefore, we ensure that you get the certificate speedily. We take great pride in providing our certificates to you as soon as possible after the tests.
Even before you get the certificate, you will receive the results of the test. First, our skilled and competent sound insulation test will engineers give you a verbal result at the site. Then, a written report is sent to you within 24 hours of a working day.
Our Guarantee
- Over 15 years experience
- State of the art equiptment
- Onsite Support
- Next Day Report Turn Around
How Sound Testing Works
Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. Sound Insulation Testing tests for both the airborne sound and the impact sound which travels through new or existing buildings . The tests cover party walls and floors between new and existing buildings, or between spaces within a new development entirely.
What is part of a Sound Insulation Test
Workers on a site will vacate the premises while the sound test is being conducted. This will facilitate an enabling and quiet environment for the tests to be carried out. Undertaking sound tests on site varies according to the size and complexity of the building project and the site conditions. Most of the time the test will be conducted in 90 minutes, for a simple, regular sized construction.
Once it is completed, the engineers will give a verbal interim result on the site and basic helpful information on what was noticed during the test, e.g. possible sound issues and future places that could cause problems.
You will get a detailed written report and sound test certificate about a day after, if possible. The way a sound test is conducted is determined by ADE of Building Regulations. It mandates that in all developments, every 10 units in a group or sub-group will undertake one set of tests. It explicitly states what a sub-group is in Section 1. There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. The volume of testing carried out on each group is written below.
Why Sound Testing is Required
Before completing a building, all new constructions should be tested for sound insulation, as stipulated by Approved Document E since 2003. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. These result limits were put in to create and maintain a uniform standard for sound resistance in different parts of a dwelling and between adjacent buildings. Sound testing is essential due to the fact that sound impacts us wherever we are, whether it’s at home, leisure or the office. Reduced noise in the partitions and flooring of a structure leads to greater ease and a more efficient environment.
There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. This is just one instance of the influence of sound insulation on our lives. It can be useful in dwellings with neighbouring units/flats/rooms which have diverse purposes, by guaranteeing that an occupant in a room will hear as little noise as possible from the neighbouring room.
Do You Need a Sound Test?
You need sound insulation testing if you:
- Build a new development of 2 or more dwellings / flats
- Convert a former single dwelling into flats
- Build a Nursing Home or rooms for residential use, i.e. hotel or hostel
- Have designs which do not adhere to Robust Details
It is imperative that sound insulation tests be undertaken, as explained and stipulated by ADE.
Either you follow the pre-completion sound testing process stipulated therein or you use Robust Details. This way, you have conformed to the requirements. Robust Details are design details for separating elements, which have been tested before to comply with Document E standards. Using Robust Details, without taking a test, limits you to the design you’ve picked. Sound testing provides more flexibility by allowing different designs and is often therefore more cost effective in many ways compared to the Robust Details Scheme. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.
Cost of Sound Insulation Testing
Simply contact us and we will be able to provide a free, no obligation quotation as to the requirements and costs for your development. Our prices are extremely competitive and we’ve worked on developments of various sizes and types. You’re also assured of a quick turnaround time for your sound insulation test report and certificates.
Ideal Period for a Sound Insulation Test
The ideal period for a sound insulation test is after the fitting of windows and doors, and before the building is finished. If you want, AF Acoustics can conduct tests before then to find out if there are any problems on your property. For your sound tests to be conducted successfully we need the property to be quiet, with workers not near the rooms to be tested during the test time (a noisy environment makes the test difficult and sometimes unsuccessful). We also need access to all units unless the test program has been compiled earlier. Finally, we need 240V power supply.
How is sound insulation testing carried out?
The method of taking the test is not complex and our sound test engineers can explain it thoroughly on site, if you wish. The separating walls undergo airborne tests while separating walls and floor undergo airborne and impact tests.
The source sound is produced with a white or pink noise generator with a dodecahedron speaker in the largest room. The sound generated and received is measured with a sound level meter. The meter is also used to measure the background sound, to ensure that it’s 10dB lower than the source sound, as is the standard. More background sound leads to creating a higher source sound. When conducting airborne sound insulation tests, two speakers are placed in each source room. The noise level in the receiving room is measured to get the sound difference between the source and receiving room.
This basic level difference is then ‘corrected’ to allow for the reverberation time (the time is taken, in seconds, for a noise source to decay by 60dB) and the existing levels of background noise monitored whilst in the receiving room. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. The sound level in the room below it is recorded. Calculations are done and the outcome is checked against ADE requirements for the type of building. Without the mathematical formulae used in the calculations, this is a simple explanation, however, it helps explain the testing process.
What Sound Insulation Testing Equipment do we use?
You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. An airborne test calculates the amount of sound moving through a separating element. The equipment we use are a sound level meter, loudspeaker and white or pink noise generator. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. The tests are administered in room with residential purposes. For example, kitchens/living spaces, lounges, bedrooms and living rooms. Test results, which are approved by Building Control and used to sign off the building, are recorded in a report and sent to the client.
Sound Insulation Testing is necessary for these types of builds:
Sound Insulation Testing checks for both airborne and impact noise travelling through new or existing buildings. This may affect party walls and floors between new and existing buildings, or between spaces within a new development.
A new building with 2 or more dwellings
This is to ensure that the sound proofing of the building is up to standard for residential purposes.
Converting a single development to flats
The development that has been converted must conform to Building Regulations sound requirements.
Designs without Robust Details
The Robust Details scheme was set up in 2004 by Robust Details Ltd as a way to help architects and builders design and construct separating elements with the confidence that the separating wall and/or floor will be capable of achieving the sound performance parameters in Approved Document E, and comply with the Building Regulations. Once the design does not strictly abide by the design from Robust Detail approved list, the structure will have to undergo a sound test to ensure it conforms to Building Regulations. The minimum criterion is based on various factors such as the purpose of the development and if it is a permanent dwelling or rooms to be used as residences like students’ accommodations and hotels.
Towns in the UK AF Acoustics Services can be Found
AF Acoustics is an acoustic consultancy providing acoustic design services to clients nationwide, especially in Dormers-Wells. Our clients include architects, planning and environmental consultancies. We also work with government agencies and private individuals. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.
Why choose AF Acoustics for Sound Insulation Testing?
Having rendered high quality service to numerous customers in Dormers-Wells, we have gotten great positive feedback and recommendation from our clientele due to the following:
Over 15 years’ experience
With more than 15 years of experience, we have a deep knowledge of our customers’ industry and provide actionable strong advice tailored to their needs. By doing this, we have been able to continuously satisfy clients in the UK and meet their acoustic needs for over 15 years, providing great value for money.
Competitive prices
To make sure you can afford high quality sound insulation projects in UK, we offer one of the most affordable prices in Dormers-Wells. Contact us immediately and we’ll give you a free quote on the sound test.
Prompt and productive consultancy
We offer strong durable advice based on your problem and give highly knowledgeable acoustic advice. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.
Adjustable test dates
Our test date options let you pick what will suit your schedule because your comfort is essential to us. Call us to get your sound testing in Dormers-Wells undertaken.
You get your report the next day
We try to provide test reports within 24 working hours. That way, you can take the right action based on the results of the test. The delivered report will be comprehensive and well detailed to ensure all relevant issues are covered and any recommendations are provided.
The sound testing services we provide
AF Acoustics offer a range of comprehensive acoustic solutions to customers nationwide, and we guarantee a high-quality and high-efficiency approach. To find out more about we can help you with your acoustics needs, call or email us right away.
Impact and airborne floor test
These are performed on floors and/or ceilings between units. The measurement of the extent of noise transmitted directly through impact from one adjoining room to another is known as impact testing. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.
Approved Document E test
Our sound insulation tests meet the requirements of Building Regulations Part E, which describes building structures resistance to the movement of sound within and from adjoining structures. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.
Sound testing
We want to give our customers the most highest chance to acquire a pass and via our offer skilled services. To make sure a new residence meets with the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw, an airborne wall test and an airborne and impact floor test will need to be conducted. When working with AF Acoustics, developers and project managers get acoustic advice right from the start of the building project. That way, they can make sure their developments have a good sound performance. Simply contact us immediately ad you’ll get a free quotation in addition to more details about our sound testing services.
Acoustic design tests in schools in accordance with BB93
Building Bulletin 93 (BB93) describes the minimum requirement for the acoustics of a school building. It also stipulates how a school can conform to Building Regulations. If you’re constructing a new school in Dormers-Wells, we can conduct a test to be certain it meets the standards of BB93.
Acoustic Design
We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.
As anybody who has needed to handle the acoustics for a building will know, it’s essential to get proper advice, early in the project from a good acoustic expert. AF Acoustics can help you with identifying the right acoustic needs and standard for your construction at the beginning period and advise you on how to meet them.
We can help with:
Acoustic detail plan for architects associated with advancements on residences adhering to ADE, BS8233, etc. Detail plans for the educational, commercial and healthcare industry so as to meet with the current criteria. Specifications and building services design for control of noise in noise sensitive areas. Public address and sound reinforcement system
To get a sound test quote for your building, call or email our highly skilled professionals
AF Acoustics is a leading acoustic consultancy. It provides the following services: architectural and building acoustics, acoustics design, survey and investigation in the field of planning and noise, and examining and controlling air vibrations while conducting air leakage tests. Our professional guidance and advice is provided to private individuals, businesses and government agencies amongst others. You can contact us by sending us an email on info@af-acoustics.com or calling us for a free quote.
Please send the following information to us
When calling or emailing us please provide the following data
Place where the building is being built
Provide the location of your building in Dormers-Wells.
Number of dwellings in the structure
Number of dwellings on the property
How many storeys are there?
For an accurate calculation of the quote, tell us the number of storeys
Dwellings arrangements per level
How many units are on each floor? Knowing this will help us give you an appropriate quotation.
Type of development
Knowing the kind of building is essential because it helps identify the type of test that will be conducted.
Newly completed construction or conversion
The testing requirement for new builds and conversion projects are different. We will need this information to determine what standard the testing ought to follow. With this information, we can easily provide you with an accurate and competitive quote on your project in little time.
Building regulations for sound test
Our sound insulation tests are conducted in accordance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building requirements. You can also get credits for Code for Sustainable Homes and EcoHomes environmental assessment projects.
Sound resistance and performance: Document E of Building Regulations (England and Wales)
We have fully accredited engineers who can visit your property to issue appropriate certification that complies with the building control.
Standard division for structures (Scotland)
According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Fully detached roofs or walkways that are not used for residential purposes do not have to take the sound tests of the Scottish Standards 5.1.
How to pass a sound test
The most efficient way to make sure you pass sound insulation test is to have a plan that puts sound insulation into consideration from the begining. You don’t have to spend too much for this and it will save you money in the long run, ensuring you don’t pay remedial or re-test expenses. We offer design services to enable separating walls and floors with good sound insulation to meet the requirements of ADE, 2003. Our consultation process is led by your project requirements and may include assessment of design reports, test of the development and multiple site visits. Take the following action to give your building the best opportunity to pass the sound insulation test: All windows and door have been fixed and are functioning Fit and seal skirting boards Light switches, plug sockets, and light fittings are adequately fixed. Our expert acoustic consultants work with planners, developers, architects and contractors from the beginning of the design stage till when the property is finished to ensure it meets the conditions of Document E 2003.
Test and report certificates
After the test, AF Acoustics’ competent and well trained engineers can let you know the verbal results of your sound test and provide feedback on issues noticed during the test. We endeavour to send an investigation and report certificate the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.
What the results look like
Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. If parts or all the building fails the test, repair work and a retest is recommended. We provide design advice to ensure your property does proper remedial and meets up with the necessary requirements.
Sound Insulation FAQ’s
The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).
New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.
Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.
In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.
We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.
We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.
When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.
The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).
This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.
Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.
New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.
We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.
Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.
We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.
You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.
Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:
- All doors, windows and seals should be fully fitted and closable
- All electrical fittings should be fitted and working
- 240V mains power must be available on-site in all rooms
- Gaps in walls and floors should be fully sealed
- All walls and ceilings should be plastered
- There should be no holes remaining in floors or ceilings
- Testers will require access to all rooms on all levels
Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.
From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.
This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.
We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.
In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.
Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.
Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.
This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.