Sound insulation testing is used to measure the resistance of sound provided by an element of a building (such as a floor or wall) between dwellings. It essentially measures the effectiveness of the sound proofing treatment installed as part of a build or property development. Part E of Building Regulations requires sound insulation in buildings and mandates that all newly completed constructions and rehabilitated developments go through sound testing.

At the completion of the test, a sound insulation certificate is issued. Without the certificate, Building Control will not release the building completion certificate to the contractors and developers of the project. Because we understand how the sound insulation certificate affects your building project, we ensure that you get it as quickly as possible after the test. We pride ourselves on the facts that our sound insulation certificates are issued with speed and efficiency.

Even before you get the certificate, you will receive the results of the test. First, our skilled and competent sound insulation test will engineers give you a verbal result at the site. Then, a written report is sent to you within 24 hours of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Does

In order to comply with Part E of the Building Regulations, developments will require the testing of separating walls and floors. The only exception is where Robust Details have been used. Sound insulation tests examine airborne and impact sound moving between separating walls and floors. The tests include party walls and floors between structures or between spaces within a new development.

The Procedures Involved in a Sound Insulation Test

Even though sound insulation testing equipment produces lots of noise, sound testing requires quiet conditions and dwellings. Because of this, workers on the site would have to leave during the time of the test, to avoid errors in the test calculation. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. Generally, a sound insulation test takes about 90 minutes for a simple, regular sized project.

Once this is done, the sound test engineers give temporary results while they’re still on the site. They will also provide suggested solutions to possible problem areas noted during testing.

A full report and individual sound test certificates can be generated and sent out the next day. The way a sound test is conducted is determined by ADE of Building Regulations. It mandates that in all developments, every 10 units in a group or sub-group will undertake one set of tests. It explicitly states what a sub-group is in Section 1. There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. How much testing that should be done on each group is listed below:

Why Should Your Dwelling Undergo Sound Testing

Sound insulation testing is required because ADE of Building Regulations has made it compulsory for all new buildings to take a sound test prior to finishing construction. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. The aim of Approved Documet E of the Building Regulations is to establish a minimum standard for the reduction in noise levels between all dwellings in a new or refurbished building. Sound testing is essential due to the fact that sound impacts us wherever we are, whether it’s at home, leisure or the office. Reduced noise in the partitions and flooring of a structure leads to greater ease and a more efficient environment.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. Sound insulation helps improve the quality of a person’s life in diverse ways. Then there are developments where each neighbouring room / flat / unit has mixed uses. If the development has passed the sound insulation test, noise is reduced to a minimum.

Does Your Development Need a Sound Insulation Test?

You need sound insulation testing if you:

  • Build a new development of 2 or more dwellings / flats
  • Convert a former single dwelling into flats
  • Build a Nursing Home or rooms for residential use, i.e. hotel or hostel
  • Have designs which do not adhere to Robust Details

It is imperative that sound insulation tests be undertaken, as explained and stipulated by ADE.

There are 2 ways you can comply. Test for sound insulation using the method of Approved Document E or use Robust Details in your development. Robust Details are design details for separating elements, which have been tested before to comply with Document E standards. Using Robust Details, without taking a test, limits you to the design you’ve picked. This becomes difficult when you need to pick a more appropriate or cost-effective design that will suit your needs. Sound tests enable you do that, making it more flexible. It also gives architects the opportunity to evaluate their design and give your structure a much better sound insulation which will increase sound performance.

How Much Will I Pay for a Sound Insulation Test?

Simply contact us and we will be able to provide a free, no obligation quotation as to the requirements and costs for your development. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

Period Sound Insulation Test Should be Carried Out

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. During the test, you should provide the following:

  • Access to all rooms. The only exception is if a schedule was created before the test time.
  • 240V power supply
  • A noiseless site

The Process of a Sound Test

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

A big or multidirectional speaker, with a generator of pink or white noise is used to the biggest room. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. Background sound is also calculated. Noise in the receiver room should be 10dB more than the background noise at all frequency measurements, so source noise is set to be greater than background noise. Airborne sound tests are conducted in this manner: two singular speaker positions are used for every source room. The noise in the receiver room is measured to determine the variations in noise level between the source and receiver room.

This basic level difference is then ‘corrected’ to allow for the reverberation time (the time is taken, in seconds, for a noise source to decay by 60dB) and the existing levels of background noise monitored whilst in the receiving room. Impact tests are conducted by fixing a tapping machine on the floor. The sound level in the room below it is recorded. Once the calculations are completed and the result is achieved, it is compared with Building Regulations Part E standards. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Testing Equipment to Expect

Our accredited engineers are testing to the current standards. We use only UKAS calibrated equipment, as stated by the building regulations. An airborne test calculates the amount of sound moving through a separating element. We use pink or white noise generator and speakers on one side of the partition. A sound level meter is used on calculating sound in both units. For impact test, a tapping machine that makes impact sound by dropping metal hammers is used. A sound level meter is used to measure in the receiving room below the room the tapping machine is in. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. Test findings are fed into a report that will be sent to the client. This report will always be acceptable to Building Control and will help you to get your development signed off.

A sound test is mandatory for these buildings:

The airborne and impact sound going through new and old buildings are evaluated by sound testing. This can impact adjoining walls and floors between the building.

A new building with 2 or more dwellings

This ensures that a sound insulation system installed in residences meets the requirements of ADE.

Converting a single development to flats

When turning the single dwelling into several flats or units, the sound performance requirements of Building Regulations must be met.

Using designs where Robust Details are not included

The Robust Details scheme was set up in 2004 by Robust Details Ltd as a way to help architects and builders design and construct separating elements with the confidence that the separating wall and/or floor will be capable of achieving the sound performance parameters in Approved Document E, and comply with the Building Regulations. If the design does not completely follow Robust Details, sound insulation testing will occur to be certain the building meets ADE criteria. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Where doses AF Acoustics conduct tests in UK?

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Earls-Court. Our clientele also include government agencies, architects, and organisations involved in planning and environmental consultancy. We’re based in several areas across the south east region of UK so that we can give you the most cost effective quote in the industry.

Why AF Acoustics is the best choice for sound insulation testing

We have worked with many organisations and individuals in Earls-Court. Our clients have endorsed us for the following reasons:

Sound testing experience of over 15 years

Our experience of over 15 years has enabled us understand our clients need and industry extensively. As a result, our advice is applicative, serviceable and will meet the client at the point of their needs. Our clients in the UK are completely satisfied with our acoustic solutions. Irrespective of the type of project you have, minor or major, you can be assured that we’ll give outstanding value for your money.

Affordably rates

To ensure all clients in Earls-Court can afford superior quality sound insulation testing, we offer some of the most competitive rates you can both in and outside Earls-Court. If in doubt, contact us now for a free no-obligation quote.

Effective and quick consultancy

We will interpret your problems and necessities, present you with vigorous ideas and provide acoustic advice through our extensive experience. Both your short and long-term needs are handled with our professional guidance and quick answers to your problems.

Adjustable test dates

Your convenience is also important to us. This is why we offer you flexible options that let you pick test dates that are most convenient for you. Call us to get your sound testing in Earls-Court undertaken.

Test reports arrive the next day

When you get your sound test report fast, you’re able to take corrective action. We try to issue reports on the next working day no matter how large or complex the project. The conveyed report will be exhaustive, covering every issue point by point to guarantee that the best suggestions are given.

The sound testing services we provide

AF Acoustics offer a variety of complete acoustic slutions to clients all over the Uk, Call or mail us today so we can provide you with more knowledge on your acoustics needs.

Impact and airborne floor test

The ceilings/floors of developments undergo impact and airborne floor testing. The calculation of the sound level transferred from one unit to another through a separating floor via impact is called an impact test. Impact and airborne testing is undertaken between party floors.

ADE testing

Our sound insulation tests meet the requirements of Building Regulations Part E, which describes building structures resistance to the movement of sound within and from adjoining structures. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound test

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. To make sure a new residence meets with the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw, an airborne wall test and an airborne and impact floor test will need to be conducted. When working with AF Acoustics, developers and project managers get acoustic advice right from the start of the building project. That way, they can make sure their developments have a good sound performance. To find out more about our sound testing services and get a free quotation, contact us now.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Acoustic design testing in schools in line with BB93

Building Bulletin 93 (BB93) explains the sound performance requirement for the acoustics of school buildings. It likewise states how a school can meet this requirement. If you’re constructing a new school in Earls-Court, we can test the sound performance to evaluate if it meets the standards of BB93.

Acoustic Design

We provide acoustic layout services and consultancy for a huge range of building types and sizes. Our experience and expertise enables us to create bespoke solutions and understand diverse acoustic products. As a result, we’re able to provide targeted solutions to the demands of the project.

As anybody who has needed to handle the acoustics for a building will know, it’s essential to get proper advice, early in the project from a good acoustic expert. AF Acoustics can help you with identifying the right acoustic needs and standard for your construction at the beginning period and advise you on how to meet them.

We can assist with:

Creating acoustic detail plans for architects involved in residential construction that conform to Document E of Building Regulations, BS8233 and so on. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Specification and design of building services for noise control in residential and other noise sensitive scenarios Improving sound and public address system in halls, conference rooms etc.

Get a sound insulation testing quotation by contacting our experts

At AF Acoustics, we are an independent acoustic consultancy. Our work embraces acoustic surveys, acoustic design and investigation work in the fields of planning and noise, architectural and building acoustics, the monitoring and control of vibrations and air tightness testing. We want to give you expert guidance and provide working solutions, whether you are an individual or an organisation. For a quotation, call or email info@af-acoustics.com

020 3372 4430 Contact us

We will need the following information:

When contacting us, please give us the following information

Location of property

Where in Earls-Court is your construction?

Number of dwellings in the structure

Total number of dwellings in the building.

How many storeys are there?

To get a precise quote, let us know the total number of floors you have.

Number of dwellings per floor

To get an appropriate quotation and determine the kind of tests to be conducted, we will also need this.

Type of development

Tell us the kind of property because different buildings require different amounts of tests.

Newly completed construction or conversion

These two go require different types performance, so let us know which one it is and you’ll get an accurate test and quotation.

Building regulations for sound test

We provide sound testing and sound insulation testing on all types of buildings, for compliance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building Standards. Testing can also gain credits for Code for Sustainable Homes and EcoHomes environmental assessment schemes.

Sound resistance: approved document of building regulations (England and Wales)

Our expert engineers can issue certificates for the sound insulation testing. They can visit the site and conduct the test that will lead to getting a certificate which is in line with Building Regulations and Building Control requirements.

Building Standards Division (Scotland)

Section 5.1 of the Scottish Building Standards stipulates that “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be performed after construction, using the procedures given in annex 5.C. of the Scottish Standards. Standard 5.1 does not apply to: fully detached houses or roofs or walkways with access solely for maintenance, or solely for the use of the residents of the dwelling below.

How to get a pass certificate for your sound test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. We offer design services that help you construct separating walls and floors with good sound performance that meet ADE demands. The degree of guidance you require can vary, from site visits and comprehensive design reports, to simpler initial testing to know the starting point for construction. The following conditions will provide you with an ample chance of passing the sound test: All windows and doors have been fitted and work Skirting boards are fixed Light switches, plug sockets, and light fittings are adequately fixed. Our professional acoustic professionals work with contractors, architects, developers, and planner from the beginning of the design to make sure that all requirements are met.

Investigation and report certificates

We try to issue a certificate to give you the details of the test evaluation and report, by the next day. After the test, our site engineers will provide verbal results and advise you on how to solve potential problem or future areas of concern. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The way the results look

A certificate will be issued to you whether the sound insulation treatment of the building meets the requirements of Document E of Building Regulations or not. If a partition wall or floor does not comply with Part E standards, repair work and another sound test will be needed. We can give robust advice on that to ensure you pass.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed