Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

At the completion of the test, a sound insulation certificate is issued. Without the certificate, Building Control will not release the building completion certificate to the contractors and developers of the project. We understand how important it is for you to get a sound insulation certificate. That’s why we go the extra mile to make sure you get your certificate as quickly as possible. In fact, we are proud of our turnaround times and our team will issue your certificates as quickly as we possibly can.

Our highly capable sound test engineers will be available on site when you need them. They will give you a verbal result of the test, once taken and a written report will be issued to you by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Test?

Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. Sound insulation tests examine airborne and impact sound moving between separating walls and floors. The tests include party walls and floors between structures or between spaces within a new development.

What is involved in Sound testing?

Workers on a site will vacate the premises while the sound test is being conducted. This will facilitate an enabling and quiet environment for the tests to be carried out. Sound insulation testing varies by size, complexity and conditions of site tested. A structure that is simple and the conventional size will usually take 90 minutes to be tested.

After the test, the sound insulation test engineers will let you know the outcome of the test and supply simple feedback of important things noted during the test; e.g. problems that might occur in the future.

You will get a detailed written report and sound test certificate about a day after, if possible. The sound testing guidelines are stipulated in Building Regulations ADE. It requires one set of test to be conducted on 10 units in a group or sub-group. You can find out what is meant by a sub-group in Section 1 of ADE. There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. How much testing that should be done on each group is listed below:

Why is Sound Insulation Testing Required? Why is it Important?

Sound insulation testing is required because ADE of Building Regulations has made it compulsory for all new buildings to take a sound test prior to finishing construction. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result. ADE ensures that new building are resistant to noise from adjoining buildings and other rooms within the same building. Testing for sound insulation is vital because sound influences how we live in the office, while relaxing or in the house. Restricting the sound that moves between floors and walls could result in a more relaxed and better surrounding.

Sound insulation and speech privacy are important because not having them results in an unfavourable environment for those living in the development. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. This is one way sound insulation can affect how a person lives. Then there are developments where each neighbouring room / flat / unit has mixed uses. If the development has passed the sound insulation test, noise is reduced to a minimum.

How Do I Know if I Need a Sound Test?

You need sound insulation testing if you:

  • Build a new development of 2 or more dwellings / flats
  • Convert a former single dwelling into flats
  • Build a Nursing Home or rooms for residential use, i.e. hotel or hostel
  • Have designs which do not adhere to Robust Details

Building Regulations Part E discusses sound testing in detail and has made it a requirement.

There are 2 ways you can comply. Test for sound insulation using the method of Approved Document E or use Robust Details in your development. Robust Details are a set of specific design details for walls and floors that have been previously tested to show compliance and must be used if this route is selected. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. This becomes difficult when you need to pick a more appropriate or cost-effective design that will suit your needs. Sound tests enable you do that, making it more flexible. Sound insulation testing can also help architects enhance their building design and in turn the sound insulation of the building.

How Much Will I Pay for a Sound Insulation Test?

To get a free quote for your dwelling, contact us. We have handled all kinds of sound insulation projects in UK and issue a report and certificate as quickly as possible. Our prices are affordable too and can beat others.

When can I carry out the sound insulation tests?

Ideally, we would conduct a test when a development nears completion, and once all internal and external doors and windows have been fitted. We can test earlier to check if there are any problems. During the test, you should provide the following:

  • Access to all rooms. The only exception is if a schedule was created before the test time.
  • 240V power supply
  • A noiseless site

The Process of a Sound Test

The method of taking the test is not complex and our sound test engineers can explain it thoroughly on site, if you wish. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

A big or multidirectional speaker, with a generator of pink or white noise is used to the biggest room. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. Noise in the background is also calculated. More noise in the background means a higher level of source sound will be created since it’s supposed to be 10dB higher than background noise on all calculated frequencies. For airborne sound tests, two individual speaker positions are used for each source room. Measurements are then made to determine the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact tests are done by placing a standardised tapping machine on the floor. The room under it is then measured for the noise levels. Calculations are done and the outcome is checked against ADE requirements for the type of building. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

Our accredited engineers are testing to the current standards. We use only UKAS calibrated equipment, as stated by the building regulations. An airborne test calculates the amount of sound moving through a separating element. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. Sound level meter is also used for impact tests. Alongside it, a tapping machine that drops metal hammers is used. Testing can only be completed on ‘habitable’ rooms. Habitable rooms can be bedrooms, lounges, living rooms and open plan kitchen/ living spaces. The outcome of the test is written in a report and sent to the customer. This report helps Building Control sign off your building.

These kinds of properties should undergo a sound insulation test:

The airborne and impact sound going through new and old buildings are evaluated by sound testing. This can impact adjoining walls and floors between the building.

Property with two or more units

This makes sure that the sound insulation for the building meets all the necessary requirements.

Converting a property into several units

The transformation of a single dwelling property into flats must adhere to the sound insulation standards of Building Regulations.

Design not using Robust Details

The Robust Detail Scheme, set up in 2004 by Robust Details Ltd, architects create design details for walls and floors that were tested formerly for sound insulation and meet the sound performance parameters stated by Part E of Building Regulations. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. Minimum criterion differs based on the type and purpose of the development. A development with rooms intended as residences, like a hostel or hotel, won’t have the same criteria as a structure for permanent dwelling.

Areas in the UK AF Acoustics Conduct Test

As an acoustics design services firm, AF Acoustics provides acoustic consultancy to various individuals and businesses nationwide, especially in Elmstead. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.

Why AF Acoustics is the best choice for sound insulation testing

Our sound insulation testing expertise at AF Acoustics have aided several home and business owners in Elmstead. We come highly recommended by our clients because of the guarantees when you work with us

We’ve been conducting sound tests for more than 15 years

Our experience of over 15 years has enabled us understand our clients need and industry extensively. As a result, our advice is applicative, serviceable and will meet the client at the point of their needs. We have over 15 years of experience satisfying the acoustic needs of UK businesses and homeowners with a proven track record on both small scale and major projects. You can always rely on us for exceptional value for money.

Affordably rates

To ensure all clients in Elmstead can afford superior quality sound insulation testing, we offer some of the most competitive rates you can both in and outside Elmstead. If in doubt, contact us now for a free no-obligation quote.

Ultrafast and efficient consultancy

We offer strong durable advice based on your problem and give highly knowledgeable acoustic advice. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Adaptable test dates

We make your convenience our priority. Therefore, we offer flexible alternatives that can help you select test dates that suit you itinerary. Call us now to schedule sound insulation testing in Elmstead

Fast turnaround for your report

When you get your sound test report fast, you’re able to take corrective action. We try to issue reports on the next working day no matter how large or complex the project. That way, you can take immediate action on the recommendations given. Our reports are thorough and cover all the important issues.

The sound testing services we provide

AF Acoustics offer a variety of complete acoustic slutions to clients all over the Uk, Phone or email us today for more information on how we can help you with your acoustic requirements.

Airborne and impact ceilings/floor tests

These are performed on floors and/or ceilings between units. The calculation of the sound level transferred from one unit to another through a separating floor via impact is called an impact test. These floors in habitable rooms of flats undergo both impact and airborne tests.

PART E Testing

AF Acoustics sound testing adheres to ADE which stipulates information bearing on the sound resistance and performance of a property. The impact sound test of new dwellings should be 62dB L’nTw or less and airborne sound insulation 45dB DnTw+Ctr or more while impact results for reconstructed properties should be 64dB L’nTw and airborne sound insulation 43dB DnTw+Ctr or more.

Sound testing

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. In new build properties an airborne test or an airborne and impact test may be required to ensure it meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We routinely give advice to developers and project managers from the beginning of the project, guaranteeing certainty when the time for a sound test is at hand. To find out more about our sound testing services and get a free quotation, contact us now.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Acoustic design testing in schools in line with BB93

For a school to meet up with Building Regulation acoustic requirements, it must adhere to Building Bulletin 93 (BB93) which explains the sound insulation expectation for schools in detail. If you’re constructing a new school in Elmstead, we can test the sound performance to evaluate if it meets the standards of BB93.

Acoustic plan

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

Getting advice on the acoustics of a development as early as possible is crucial. AF Acoustics can enable you to do that by advising you on the appropriate acoustic requirements of your property very early in the building process and recommending what to do to fulfil them.

We are able to assist with:

Acoustic detail plan for architects associated with advancements on residences adhering to ADE, BS8233, etc. Detail plans for the educational, commercial and healthcare industry so as to meet with the current criteria. Specification and design of building services for noise control in residential and other noise sensitive scenarios Increasing sound through public enterprise and sound reinforcement systems in conference rooms, halls, lecture theatres and the like.

Call Our Experts Now For A Sound Insulation Testing Quote

Our services at AF Acoustics include acoustic design and investigation, evaluation and calculation of noise, acoustic survey, building an architectural acoustics and air pressure testing. We will give you sound advice and guidance no matter who you are or the kind of project you have. To get an accurate quotation, either call us or email info@af-acoustics.com

020 3372 4430 Contact us

We will need the following information:

Give us the following information when contacting us

Location of development

Where is your property located in Elmstead?

Total number of dwellings

What is the number of units in the development?

Number of floors in the building

To give you an appropriate quotation, would like to know the number of floors in your building.

Number of dwelling units per storey

How many units are on each floor? Knowing this will help us give you an appropriate quotation.

Building type

Let us know the type of development you have so that we can undertake the required tests for it.

New dwelling or converted property

The testing requirements for new dwellings and converted properties are not the same. Tell us the type of building you have so that we give you the right quote.

Building regulations for sound insulation test

We undertake sound insulation test on various buildings that adhere to Building Regulations Document E. Testing can also enable you get more credits for Code for Sustainable Homes and EcoHomes environmental assessment constructions.

Sound resistance: approved document of building regulations (England and Wales)

Our certified engineers can come to your building whenever it might suit you to undertake sound insulation testing to Part E of Building Regulations adherence, recognised by Building Control.

Building Standards Division (Scotland)

Section 5.1 of the Scottish Building Standards explicitly describes expected energy performance of dwellings. It states, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests, which are conducted after building utilizing the methodology given in annex 5.C. of the Scottish Standard 5.1 does not apply to: completely disconnected houses, rooftops and walkways with access exclusively for the use of the occupants of the home underneath.

How to get a pass certificate for your sound test

The most effective way to ensure you pass your sound test is to plan the project with sound insulation in mind. This does not need to be costly, and can save considerable time and expense at the end of the project, not to mention avoiding escalating remedial and re-test costs. If you are unsure of how to build the separating floor and wall constructions and associated junctions across your development to satisfy the requirements of Document E 2003, we can offer design advice. Our consultation process is led by your project requirements and may include assessment of design reports, test of the development and multiple site visits. The following criteria should be followed to provide you with the best chance of passing your sound test: Inner and outer doors and windows have been installed and can be used Skirting boards are fixed are sealed Light switches, plug sockets, and light fittings are adequately fixed. We work with several professionals in construction from the beginning of the design stage to the completion of the development to make certain it conforms to Document E 2003 of Building Regulations.

Investigation and report certificates

To get details of the results of a completed sound insulation test, we will provide you with an analysis and report certificate. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The way the results look

A certificate will be issued to you whether the sound insulation treatment of the building meets the requirements of Document E of Building Regulations or not. In the event of a wall or floor not achieving the Part E requirements, it may be necessary to carry out remedial works before having another sound test carried out. We can provide you with remedial design advice to help you achieve the Building Regulations requirements.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed