Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

Not having a sound insulation certificate issued after a test, has resulted in additional costs and expenses for developers. Any development that has not taken a sound test will not be given a completion certificate by Building Control. The significance of a sound insulation certificate cannot be overrated. Therefore, we ensure that you get the certificate speedily. In fact, we pride ourselves on issuing our sound insulation testing certificates as quickly as possible.

Our highly capable sound test engineers will be available on site when you need them. They will give you a verbal result of the test, once taken and a written report will be issued to you by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Testing Does

Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

What is part of a Sound Insulation Test

Even though sound insulation testing equipment produces lots of noise, sound testing requires quiet conditions and dwellings. Because of this, workers on the site would have to leave during the time of the test, to avoid errors in the test calculation. Sound insulation testing varies by size, complexity and conditions of site tested. Most of the time the test will be conducted in 90 minutes, for a simple, regular sized construction.

Once this is done, the sound test engineers give temporary results while they’re still on the site. They will also provide suggested solutions to possible problem areas noted during testing.

A full and thorough report with the certificate of the test will be given to you within 24 working hours. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). ADE goes on to define and group the type of structures that will undergo testing. They are houses, flats and rooms that are being used or are planned to be used as residences; such as student accommodation, care homes and hotel rooms. Find below the testing stipulation for each kind of development.

Importance of Sound Insulation Testing

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. This Approved Document, as part of UK Building Regulations helps to ensure that new buildings are constructed to minimum standards that provide reasonable resistance to sound from other parts of the same building and from adjacent buildings. Testing for sound insulation is vital because sound influences how we live in the office, while relaxing or in the house. Restricting the sound that moves between floors and walls could result in a more relaxed and better surrounding.

Sound insulation and having privacy while speaking are crucial for a number of reasons. When sound insulation is deficient, it can cause discomfort to occupants. It would mean noise moving from one flat to another in a block of flats. If, for example, an occupant works at night and happens to hear loud music from a neighbour upstairs on a weekend night, it would be very discomforting. This is just one example of how sound insulation can affect the quality of life of people in different ways. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

How to Know if You Need Sound Insulation Testing

If you’re doing one of the following, then you need a sound test:

  • Constructing a building that has two or more units
  • Constructing a nursing home or rooms that will be lived in, e.g. hotel room or hostel
  • Converting a single development to flats
  • Using designs where Robust Details are not included

Sound insulation is covered and made mandatory under Approved Document E of The Building Regulations.

There are two ways in which to show compliance. You can either test to the regime set out in Approved Document E (ADE), or pay to use Robust Details. If you choose the latter, you must use Robust Details which are a approved design details for partitioning walls and floors. The Robust Details scheme means that testing is not necessary, but is strictly limited to the design given in the Robust Details approved list. Sound testing provides more flexibility by allowing different designs and is often therefore more cost effective in many ways compared to the Robust Details Scheme. Sound insulation testing can also help architects enhance their building design and in turn the sound insulation of the building.

How Much Will I Pay for a Sound Insulation Test?

Call us or email us to get a free quotation for your building. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

When Should the Sound Tests be done?

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. During the test, you should provide the following:

  • Access to all rooms. The only exception is if a schedule was created before the test time.
  • 240V power supply
  • A noiseless site

How is sound insulation testing carried out?

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. The separating walls undergo airborne tests while separating walls and floor undergo airborne and impact tests.

The test uses a dodecahedron speaker and pink or white noise generator for source sound. The sound source is placed in the largest room of the two. A sound level meter calculates the noise in the source room and receiver room. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. For airborne tests, two speakers positions are used in the source room and the level of noise entering into the receiving partition room is measured. That way the difference in sound level is calculated.

The variations or differences in noise level are ‘corrected’ to take into consideration the already present background noise in the receiving room and the reverberation time – measure of time needed for a sound to decay or be absorbed in a closed room by 60dB. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. Noise level in the room below is measured at various different frequencies. Calculations based on these measurements are undertaken and the results compared to the Building Regulations Part E requirements for the given type of the building. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Equipment do we use?

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. An airborne test is used to check how much sound is moving through the air between partitions. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. For impact sound testing, the equipment used is a tapping machine that uses dropping hammers to create noise and a sound level meter. Testing is done on rooms that can be lived in. E.g. lounges, kitchens, bedrooms and living rooms. Test findings are fed into a report that will be sent to the client. This report will always be acceptable to Building Control and will help you to get your development signed off.

Sound insulation testing is essential for these dwelling types:

For sound testing we usually undertake impact and airborne sound test on buildings. This affects the separating floors and walls between habitable rooms of buildings and developments.

Property with two or more units

This ensures that a sound insulation system installed in residences meets the requirements of ADE.

Conversions of former single dwelling properties into flats

The transformation of a single dwelling property into flats must adhere to the sound insulation standards of Building Regulations.

Design not using Robust Details

The Robust Details scheme was set up in 2004 by Robust Details Ltd as a way to help architects and builders design and construct separating elements with the confidence that the separating wall and/or floor will be capable of achieving the sound performance parameters in Approved Document E, and comply with the Building Regulations. If the building design does not strictly adhere to Robust Details, a sound insulation test becomes necessary to meet Building Regulations. The minimum requirements during testing will depend on a variety of factors such as if the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

Towns in the UK AF Acoustics Services can be Found

AF Acoustics provides acoustic design services to customer nationwide, especially in Fortis-Green. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.

Why choose AF Acoustics for Sound Insulation Testing?

We have worked with many organisations and individuals in Fortis-Green. Our clients have endorsed us for the following reasons:

More than 15 years’ experience

Our experience of over 15 years has enabled us understand our clients need and industry extensively. As a result, our advice is applicative, serviceable and will meet the client at the point of their needs. We have over 15 years of experience satisfying the acoustic needs of UK businesses and homeowners with a proven track record on both small scale and major projects. You can always rely on us for exceptional value for money.

Competitive prices

To ensure all clients in Fortis-Green can afford superior quality sound insulation testing, we offer some of the most competitive rates you can both in and outside Fortis-Green. If in doubt, contact us now for a free no-obligation quote.

Ultrafast and efficient consultancy

We offer strong durable advice based on your problem and give highly knowledgeable acoustic advice. When you reach out to us for professional advice, we make certain that we render accurate solutions rapidly. We suggest productive answers that handle your present and long-term desires to the maximum.

Adaptable test dates

Your convenience is also important to us. This is why we offer you flexible options that let you pick test dates that are most convenient for you. Call us now to schedule sound insulation testing in Fortis-Green

Get your test reports quickly

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. That way, you can take immediate action on the recommendations given. Our reports are thorough and cover all the important issues.

The sound testing services we provide

AF Acoustics offer a variety of complete acoustic slutions to clients all over the Uk, Call or mail us today so we can provide you with more knowledge on your acoustics needs.

Impact and Airborne floor test

The ceilings/floors of developments undergo impact and airborne floor testing. The calculation of the sound level transferred from one unit to another through a separating floor via impact is called an impact test. Impact and airborne testing is undertaken between party floors.

Approved Document E test

Document E of Building Regulations requires certain criteria for the sound performance of a dwelling. Our sound insulation tests are conducted in accordance to these criteria. The impact sound test of new dwellings should be 62dB L’nTw or less and airborne sound insulation 45dB DnTw+Ctr or more while impact results for reconstructed properties should be 64dB L’nTw and airborne sound insulation 43dB DnTw+Ctr or more.

Sound testing

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. In new build properties an airborne test or an airborne and impact test may be required to ensure it meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We frequently give robust advice to project managers and developers from the start of the construction, ensuring that they’ll have adequate sound insulation to pass a sound test. Simply contact us immediately ad you’ll get a free quotation in addition to more details about our sound testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 testing of acoustic design in schools

For a school to meet up with Building Regulation acoustic requirements, it must adhere to Building Bulletin 93 (BB93) which explains the sound insulation expectation for schools in detail. If you’re developing a new school in Fortis-Green, we can test it to find out if it aligns with BB93.

Acoustic Design

AF Acoustics give definite design services and consultancy services to all types of developments. We create bespoke solution and can provide information on the best available acoustic products. We will tailor our design solutions to your project.

As anybody who has needed to handle the acoustics for a building will know, it’s essential to get proper advice, early in the project from a good acoustic expert. AF Acoustics can help you with identifying the right acoustic needs and standard for your construction at the beginning period and advise you on how to meet them.

We are able to help with:

Acoustic detail design for architects involved in residential developments for compliance with Part E Regs, BS8233, and so on. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Specification and design of building services for noise control in residential and other noise sensitive scenarios Public address and sound reinforcement system

Call Our Experts Now For A Sound Insulation Testing Quote

As an independent acoustics consultancy, AF Acoustics is able to provide extensive acoustic survey and design, investigations in the field of planning and noise, architectural and building acoustics, and air permeability testing. Whether you are a company or a private individual, we are here to advise and guide you. If you would like a friendly and accurate sound insulation testing quote, please send an email to info@af-acoustics.com or give us a call.

020 3372 4430 Contact us

We will need the following information:

Give us the following information when contacting us

Place where the building is being built

Where is your development situated in Fortis-Green

Number of dwellings in the structure

Total number of dwellings in the building.

Number of levels in the structure

For an accurate calculation of the quote, tell us the number of storeys

Configuration of dwellings (no. of units per level)

This will also be needed to determine scope of the testing and provide an accurate quote

Building type

Tell us the kind of property because different buildings require different amounts of tests.

New dwelling or converted property

The testing requirement for new builds and conversion projects are different. We will need this information to determine what standard the testing ought to follow. With this information, we can easily provide you with an accurate and competitive quote on your project in little time.

Sounds test in accordance with building regulations

Our sound insulation tests are conducted in accordance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building requirements. You can also get credits for Code for Sustainable Homes and EcoHomes environmental assessment projects.

Part E of building regulations resistance to the passage of sound (England and Wales)

Our certified engineers can come to your building whenever it might suit you to undertake sound insulation testing to Part E of Building Regulations adherence, recognised by Building Control.

Scotland Standard division for completed constructions

In the words of Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” The following are exempt from the testing techniques given in annex 5.C. of the Scottish Standard and Standard 5.1 – completely segregated rooftops, houses or walkways whose access is only used for upkeep or for the utilization of the inhabitants of the dwelling beneath.

How to pass a sound test

The best method to guarantee you pass your sound test is to design the building with a view to good sound insulation performance. This shouldn’t be exorbitant, and can save time and cost at the end, without your having to correct sound problem or pay for a re-test. Are you uncertain that the separating floor and walls you will build will adhere to Document E 2003 conditions? You can book our design services. Our consultation process is led by your project requirements and may include assessment of design reports, test of the development and multiple site visits. The following will give you a better chance of passing the sound test: All windows and doors have been fitted and work Skirting boards are fitted and sealed Light switches, light fittingsand plug sockets are properly fitted Our experienced acoustic consultants work with developers, contractors, architects and planners of all sizes from the early design stage to help minimise any potential issues right through to project completion, ensuring that all properties are compliant with Building Regulations Document E 2003.

Certificates for test evaluation and report

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern. A full report and individual sound test certificates can be generated and sent out usually the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What the results look like

A sound insulation certificate will be sent to you whether the property has a good sound performance in accordance with ADE or not. We can provide professional advice on designs that will surpass Document E standards if the building fails the test.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed