Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. The Building Regulations Approved Document E (ADE) states all new dwellings and renovated constructions should undergo sound testing.

Not having a sound insulation certificate issued after a test, has resulted in additional costs and expenses for developers. Any development that has not taken a sound test will not be given a completion certificate by Building Control. As a result of this, we try to ensure that you are issued with a sound insulation certificate as fast as possible. We pride ourselves on the facts that our sound insulation certificates are issued with speed and efficiency.

AF Acoustics’ competent and well-trained engineers, who will be available for testing, can even let you know the verbal results of your sound test. You will receive a written report in the space of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Does

Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. The airborne and impact sound going through new and old structures are evaluated by sound testing. This can impact adjoining walls and floors between the structures.

What is involved in Sound testing?

The sound test itself produces very high levels of noise but also requires relatively quiet conditions on site. For these reasons, any workforce in the testing area will have to leave temporarily to ensure test accuracy. The way a sound test is administered depends on the size and type of building and the development’s condition. A structure that is simple and the conventional size will usually take 90 minutes to be tested.

Once it is completed, the engineers will give a verbal interim result on the site and basic helpful information on what was noticed during the test, e.g. possible sound issues and future places that could cause problems.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. The sound testing guidelines are stipulated in Building Regulations ADE. It requires one set of test to be conducted on 10 units in a group or sub-group. You can find out what is meant by a sub-group in Section 1 of ADE. There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. The volume of testing carried out on each group is written below.

Why is Sound Insulation Testing Required? Why is it Important?

After the 2003, Approved Document E mandates that all new structures in UK must take a sound insulation test before completion. Results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. These result limits were put in to create and maintain a uniform standard for sound resistance in different parts of a dwelling and between adjacent buildings. Testing for sound insulation is vital because sound influences how we live in the office, while relaxing or in the house. Restricting the sound that moves between floors and walls could result in a more relaxed and better surrounding.

Sound insulation and speech privacy are important because not having them results in an unfavourable environment for those living in the development. For example, in a block of flats, your upstairs neighbour may (and not unreasonably) like to have friends over at the weekend, resulting in the playing of loud music. However, the downstairs occupant may be working nights and sleeping throughout the day, thus any inadequate sound insulation between these two flats would cause great disturbance and distress to the downstairs occupant. This is one way sound insulation can affect how a person lives. Sound insulation is also effective in buildings that have flats with mixed uses. If the building passed the sound test, you can be sure that noise reduction will be effective.

Do I Need a Sound Insulation Test?

You need a sound insulation test if you’re:

  • Constructing a nursing home or residential rooms like hostel or hotel rooms,
  • Converting a building with a single dwelling into flats,
  • Constructing a property with two or more units,
  • Using designs without Robust Details to build

Document E of the Building Regulations explains sound insulation testing and makes it a necessity.

To conform, you can either follow the procedure outlined in ADE or make use of Robust Details. Robust Details are a set of specific design details for walls and floors that have been previously tested to show compliance and must be used if this route is selected. You also cannot expand or tweak the design from the Robust Detail Approved listing. However, you are exempt from the sound test. This becomes difficult when you need to pick a more appropriate or cost-effective design that will suit your needs. Sound tests enable you do that, making it more flexible. On-site pre-completion sound insulation testing gives architects more insight and ability to make their design lead to constructions that have a higher sound performance.

Price for Sound Insulation Testing

Contact us and we’ll give you a free quote on the sound test cost based on the requirements of your building. We have worked throughout the country on all sizes of project, and should a sound insulation report and certificates be required, we can provide the fastest turnaround times and most competitive prices available. If you get a better quote elsewhere, simply forward it to us and we will try and beat it!

Ideal Period for a Sound Insulation Test

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

The Process of a Sound Test

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. For partition walls, airborne tests are carried out. For floors there are two types, airborne and impact tests.

The source sound is produced with a white or pink noise generator with a dodecahedron speaker in the largest room. A sound level meter calculates the noise in the source room and receiver room. Background sound is also calculated. Noise in the receiver room should be 10dB more than the background noise at all frequency measurements, so source noise is set to be greater than background noise. When conducting airborne sound insulation tests, two speakers are placed in each source room. The noise level in the receiving room is measured to get the sound difference between the source and receiving room.

This basic level difference is then ‘corrected’ to allow for the reverberation time (the time is taken, in seconds, for a noise source to decay by 60dB) and the existing levels of background noise monitored whilst in the receiving room. Impact tests are carried out by means of a tapping machine placed on the floor to be measured. The noise level is then recorded in the room below. Calculations based on these measurements are undertaken and the results compared to the Building Regulations Part E requirements for the given type of the building. This is a simple way of explaining how a sound test is conducted.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

Our high-tech sound insulation machines are UKAS calibrated and our accredited expert engineers conduct the test using Building Regulations present criteria. An airborne test calculates the amount of sound moving through a separating element. Equipment used for the test include a noise generator, speakers and sound level meter. For impact test, a tapping machine that makes impact sound by dropping metal hammers is used. A sound level meter is used to measure in the receiving room below the room the tapping machine is in. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. Test results, which are approved by Building Control and used to sign off the building, are recorded in a report and sent to the client.

These kinds of properties should undergo a sound insulation test:

For sound testing we usually undertake impact and airborne sound test on buildings. This affects the separating floors and walls between habitable rooms of buildings and developments.

Two or more new build dwellings or flats

This ensures that a sound insulation system installed in residences meets the requirements of ADE.

A single dwelling that was turned into a development with several flats or units

When turning the single dwelling into several flats or units, the sound performance requirements of Building Regulations must be met.

Designs without Robust Details

Architects are able to use pre-tested and approved Robust Details design for partitioning walls and floors. The Robust Details scheme was formed in 2004 by Robust Details Ltd. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. Minimum criterion differs based on the type and purpose of the development. A development with rooms intended as residences, like a hostel or hotel, won’t have the same criteria as a structure for permanent dwelling.

Where doses AF Acoustics conduct tests in UK?

AF Acoustics renders acoustics design services and consultancy to customers all over the UK, especially in Haggerston. Our clientele also include government agencies, architects, and organisations involved in planning and environmental consultancy. Our consultants can be found in various places in the south east region. This way you get an affordable price.

Why AF Acoustics is the best choice for sound insulation testing

Having rendered high quality service to numerous customers in Haggerston, we have gotten great positive feedback and recommendation from our clientele due to the following:

15 years’ experience

We are able to offer helpful functional solutions that will solve our customer’s needs. We have over 15 years of experience satisfying the acoustic needs of UK businesses and homeowners with a proven track record on both small scale and major projects. You can always rely on us for exceptional value for money.

Best rates available

We want to ensure that you get the best value for your money. That is why we have one of the most unbeatable rates in and outside Haggerston. Call us or email today to get a free quotation.

Effective and quick consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. When you reach out to us for professional advice, we make certain that we render accurate solutions rapidly. We suggest productive answers that handle your present and long-term desires to the maximum.

Adaptable test dates

Your convenience is also important to us. This is why we offer you flexible options that let you pick test dates that are most convenient for you. If you want to schedule sound insulation testing in Haggerston, phone or email us immediately.

Fast turnaround for your report

The sooner you get a report on the completed sound insulation test, the sooner you can take appropriate action. We strive to deliver next day reporting in all scenarios regardless of the complexity or size of the project. That way, you can take immediate action on the recommendations given. Our reports are thorough and cover all the important issues.

Sound insulation testing services AF Acoustics undertake

With AF Acoustics, you get a highly effective and expert acoustic advice which our customers all over UK have benefited from. Telephone or email us today for more data on how we can assist you with your acoustic requirements.

Impact and airborne floor test

Impact and airborne floor tests are conducted on ceilings/floors between rooms. An impact test measures the levels of noise transmitted directly through a separating construction. Airborne and impact tests are conducted on the floor partitions between liveable rooms.

Testing in line with Part E of Building Regulations

Our sound insulation testing in accordance with Building Regulations Approved Document E, which sets out details pertaining to the resistance to the passage of sound. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw for new structures. Converted properties get a slightly different requirement. Expected minimum airborne sound insulation test result is 43dB DnTw+Ctr while expected maximum impact sound test result is 64dB L’nTw.

Sound insulation test

With our professional and highly skilled expertise, we are willing to work with our clients to help them get a pass certificate in every situation. In newly completed constructions, an airborne wall test and an airborne and impact floor test will be needed to meets the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We routinely give advice to developers and project managers from the beginning of the project, guaranteeing certainty when the time for a sound test is at hand. Call or email us now for more details on our sound insulation testing services and for a quotation to be sent to you, free of charge.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) describes the minimum requirement for the acoustics of a school building. It also stipulates how a school can conform to Building Regulations. If you’re developing a new school in Haggerston, we can test it to find out if it aligns with BB93.

Acoustic plan

AF Acoustics provide extensive design services and consultancy on a variety of buildings. We have the ability and experience to create bespoke solutions, and have solid working information of accessible acoustic items. We will create design solutions appropriate for the explicit requests of the construction.

As anyone who has had to deal with the acoustic properties of a building will know, it’s important to get the correct advice, as early as possible from a good acoustic consultant. AF Acoustics can help you to identify the correct acoustic requirements for your project at an early stage and advise on the best means to meet them using expert knowledge of acoustic design.

We are able to assist with:

Creating acoustic detail plans for architects involved in residential construction that conform to Document E of Building Regulations, BS8233 and so on. Detail layout for the commercial, health and educational constructions in order to align with regulations. Specification and design of building services for noise control in residential and other noise sensitive scenarios Improving sound and public address system in halls, conference rooms etc.

Contact our professionals for a sound test quotation

Our services at AF Acoustics include acoustic design and investigation, evaluation and calculation of noise, acoustic survey, building an architectural acoustics and air pressure testing. Our expert consultation is available to individuals and companies with all types and sizes of constructions. We will give you free quotation with highly competitive rates. Simply call us or email info@af-acoustics.com

020 3372 4430 Contact us

Provide us with the following data

When contacting us, please give us the following information

Construction’s location

Where is your property located in Haggerston?

Number of dwellings

Total number of dwellings in the structure

Number of levels in the structure

To get a precise quote, let us know the total number of floors you have.

Number of dwellings per floor

Tell us how many units are in your structure so that we can give you the right calculation for your quotation and know the scope of the test.

Building type

The type of building, as different building types typically require a different testing.

New dwelling or converted property

Newly completed constructions and refurbished structures have different requirements for sound insulation testing. This is why it’s important to provide this information beforehand. Our quotation is available at any time.

Building regulations for sound test

We provide sound testing and sound insulation testing on all types of buildings, for compliance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building Standards. Testing can also gain credits for Code for Sustainable Homes and EcoHomes environmental assessment schemes.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

We can have fully accredited engineers sent to your property at your convenience to provide certification for Building Regulations Part E compliance, recognised by Building Control.

Scotland Standard division for completed constructions

According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Fully detached roofs or walkways that are not used for residential purposes do not have to take the sound tests of the Scottish Standards 5.1.

How to make sure you pass your sound test

Make sure you pass your sound test by having efficient sound insulation included in the building design. It saves time and money and helps you avoid repair work and re-test expenses. Are you uncertain that the separating floor and walls you will build will adhere to Document E 2003 conditions? You can book our design services. We can study design reports, complete site visits and sound test the development to provide you with the level of assessment and consultation that your project requires from start to finish. The following conditions will provide you with an ample chance of passing the sound test: Windows and internal and external doors are fitted and operable Fit and seal skirting boards Light fittings and switches and plug sockets are fitted and working. Our professional acoustic professionals work with contractors, architects, developers, and planner from the beginning of the design to make sure that all requirements are met.

Analysis and Report Certificates

After the test, AF Acoustics’ competent and well trained engineers can let you know the verbal results of your sound test and provide feedback on issues noticed during the test. We endeavour to send an investigation and report certificate the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The results

A certificate will be issued to you whether the sound insulation treatment of the building meets the requirements of Document E of Building Regulations or not. If a partition wall or floor does not comply with Part E standards, repair work and another sound test will be needed. We can give robust advice on that to ensure you pass.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00