Sound insulation testing involves the use of specialist equipment to examine how much sound is reduced off by floors and walls, of a building. It checks if a dwelling’s sound proofing treatment meets the requirements set out in Approved Document E. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

Not having a sound insulation certificate issued after a test, has resulted in additional costs and expenses for developers. Any development that has not taken a sound test will not be given a completion certificate by Building Control. We understand how important it is for you to get a sound insulation certificate. That’s why we go the extra mile to make sure you get your certificate as quickly as possible. In fact, we are proud of our turnaround times and our team will issue your certificates as quickly as we possibly can.

AF Acoustics’ competent and well-trained engineers, who will be available for testing, can even let you know the verbal results of your sound test. You will receive a written report in the space of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Test?

In order to comply with Part E of the Building Regulations, developments will require the testing of separating walls and floors. The only exception is where Robust Details have been used. Sound insulation tests examine airborne and impact sound moving between separating walls and floors. The tests include party walls and floors between structures or between spaces within a new development.

What is involved in Sound Insulation Testing

Even though sound insulation testing equipment produces lots of noise, sound testing requires quiet conditions and dwellings. Because of this, workers on the site would have to leave during the time of the test, to avoid errors in the test calculation. The process of a sound test is determined by the size and complexity of the site being tested. If the site is simple and of regular size, it typically takes about 90 minutes to complete the sound test.

Once it is completed, the engineers will give a verbal interim result on the site and basic helpful information on what was noticed during the test, e.g. possible sound issues and future places that could cause problems.

The entire report and individual sound test certificate will be sent to you the day after. The way a sound test is conducted is determined by ADE of Building Regulations. It mandates that in all developments, every 10 units in a group or sub-group will undertake one set of tests. It explicitly states what a sub-group is in Section 1. Buildings are divided into three kinds for the test – houses, flats and rooms built for or converted to residential dwellings, like student accommodation, care homes and hotel rooms. Find below the testing stipulation for each kind of development.

Why is Sound Insulation Testing Required? Why is it Important?

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. ADE ensures that new building are resistant to noise from adjoining buildings and other rooms within the same building. When sound resistance is high in party walls and floors, the environment is more comfortable, since sound affects every aspect of our lives – work environment, home environment and while relaxing. This is why sound testing is crucial.

Sound insulation and speech privacy are critical for a variety of reasons. Inadequate sound insulation can be extremely distressing to those affected by it. It would mean noise moving from one flat to another in a block of flats. If, for example, an occupant works at night and happens to hear loud music from a neighbour upstairs on a weekend night, it would be very discomforting. Sound insulation impacts people’s lives in various ways. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

Do You Need a Sound Test?

Are you converting your property into several units? Does your design not use Robust Details? Are you constructing a new building with more than two rooms? Are you building a nursing home or rooms that will used for residential purposes, like hotels and hostels? If so, your structure needs to undergo a sound test. Sound insulation is covered and made mandatory under Approved Document E of The Building Regulations.

All you have to do is follow the guidelines listed in the document or pay to use Robust Details and you will have fulfilled the requirements. Robust details are separating elements that have been pre-tested and conform to Approved Document E sound insulation standards. Using Robust Details, without taking a test, limits you to the design you’ve picked. Sound insulation testing is a more flexible approach. You can pick from a plethora of designs, as opposed to Robust Details. It also gives architects the opportunity to evaluate their design and give your structure a much better sound insulation which will increase sound performance.

Price for Sound Insulation Testing

We can send quotation that’s completely free of charge and is based on the kind of development you have. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

When Should the Sound Tests be done?

The ideal period for a sound insulation test is after the fitting of windows and doors, and before the building is finished. If you want, AF Acoustics can conduct tests before then to find out if there are any problems on your property. To be able to conduct sound insulation testing we require the provision of a 240V power supply, and a quiet site (a noisy site can make conducting the tests extremely difficult). Access will be required to all rooms of the development unless a test schedule is determined in advance.

The Process of a Sound Test

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. The boundary floors and walls get airborne tests. Floors get an additional impact test.

The airborne sound insulation test is carried out with a large speaker or dodecahedron speaker, using a white or pink noise generator to create the source sound, almost always in the largest room of the two rooms under testing. The sound generated and received is measured with a sound level meter. The background noise level is also measured. The higher the background noise then the higher the source noise will need to be set, since the resulting noise level in the receiver room needs to be 10dB higher than the background noise at all measured frequencies. When conducting airborne sound insulation tests, two speakers are placed in each source room. The noise level in the receiving room is measured to get the sound difference between the source and receiving room.

This basic level difference is then ‘corrected’ to allow for the reverberation time (the time is taken, in seconds, for a noise source to decay by 60dB) and the existing levels of background noise monitored whilst in the receiving room. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. Noise level in the room below is measured at various different frequencies. Calculations are undertaken, and results achieved. The results are crosschecked to ensure they meet Document E of Building Regulations target. This is a simple way of explaining how a sound test is conducted.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. Airborne sound test is the measurement of sound moving through the air through a wall or floor. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. A sound level meter and a tapping machine which drops metal hammers is used for impact testing. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. Test findings are fed into a report that will be sent to the client. This report will always be acceptable to Building Control and will help you to get your development signed off.

Sound Insulation Testing is necessary for these types of builds:

The airborne and impact sound going through new and old buildings are evaluated by sound testing. This can impact adjoining walls and floors between the building.

Property with two or more units

This is to ensure that the sound proofing of the building is up to standard for residential purposes.

Converting a single development to flats

All the units that have been built are to be constructed in alignment with Part E of Building Regulations.

Design not using Robust Details

The Robust Detail Scheme, set up in 2004 by Robust Details Ltd, architects create design details for walls and floors that were tested formerly for sound insulation and meet the sound performance parameters stated by Part E of Building Regulations. If the building design does not strictly adhere to Robust Details, a sound insulation test becomes necessary to meet Building Regulations. The minimum requirements during testing will depend on a variety of factors such as if the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

Areas in the UK AF Acoustics Conduct Test

AF Acoustics renders acoustics design services and consultancy to customers all over the UK, especially in Hatton. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. We’re based in several strategic locations in the south east of UK to enable you get the best quotation and price possible.

Why AF Acoustics is the best choice for sound insulation testing

Our sound insulation testing expertise at AF Acoustics have aided several home and business owners in Hatton. We come highly recommended by our clients because of the guarantees when you work with us

We’ve been conducting sound tests for more than 15 years

With more than 15 years of experience, we have a deep knowledge of our customers’ industry and provide actionable strong advice tailored to their needs. We have over 15 years of experience satisfying the acoustic needs of UK businesses and homeowners with a proven track record on both small scale and major projects. You can always rely on us for exceptional value for money.

Great prices

To make sure you can afford high quality sound insulation projects in UK, we offer one of the most affordable prices in Hatton. Contact us immediately and we’ll give you a free quote on the sound test.

Fast and efficient consultancy

We offer strong durable advice based on your problem and give highly knowledgeable acoustic advice. Both your short and long-term needs are handled with our professional guidance and quick answers to your problems.

Adaptable test dates

We make your convenience our priority. Therefore, we offer flexible alternatives that can help you select test dates that suit you itinerary. Call us to get your sound testing in Hatton undertaken.

Next day reporting

We try to provide test reports within 24 working hours. That way, you can take the right action based on the results of the test. We make certain all relevant issues are covered and quality tips are supplied by detailing all the aspects of the test in the report.

The sound testing services we provide

AF Acoustics offer a range of comprehensive acoustic solutions to customers nationwide, and we guarantee a high-quality and high-efficiency approach. Phone or email us today for more information on how we can help you with your acoustic requirements.

Impact and Airborne floor test

These are performed on floors and/or ceilings between units. The measurement of the extent of noise transmitted directly through impact from one adjoining room to another is known as impact testing. The adjoining floors/ceilings of rooms intended as residences usually have both impact and airborne sound tests.

Approved Document E test

AF Acoustics sound testing adheres to ADE which stipulates information bearing on the sound resistance and performance of a property. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound Insulation Testing

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. A new dwelling may have to undergo an airborne and impact test to meet the benchmark of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Call or email us now for more details on our sound insulation testing services and for a quotation to be sent to you, free of charge.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. If you’re constructing a new school in Hatton, we can test the sound performance to evaluate if it meets the standards of BB93.

Acoustic design details

AF Acoustics provide extensive design services and consultancy on a variety of buildings. We have the ability and experience to create bespoke solutions, and have solid working information of accessible acoustic items. We will create design solutions appropriate for the explicit requests of the construction.

As anybody who has needed to handle the acoustics for a building will know, it’s essential to get proper advice, early in the project from a good acoustic expert. AF Acoustics can help you with identifying the right acoustic needs and standard for your construction at the beginning period and advise you on how to meet them.

We will help you with:

Acoustic detail plan for architects associated with advancements on residences adhering to ADE, BS8233, etc. Detail designs for the health, educational and commercial projects in order to meet up with the necessary requirements. Specifications and design details that enable good sound insulation and reduction of noise in residences. Public address and sound reinforcement (conference rooms / lecture theatres etc.)

Contact our professionals for a sound test quotation

AF Acoustics is a leading acoustic consultancy. It provides the following services: architectural and building acoustics, acoustics design, survey and investigation in the field of planning and noise, and examining and controlling air vibrations while conducting air leakage tests. Our expert consultation is available to individuals and companies with all types and sizes of constructions. We will give you free quotation with highly competitive rates. Simply call us or email info@af-acoustics.com

020 3372 4430 Contact us

Provide us with the following data

When calling or emailing us please provide the following data

Construction’s location

Where is your development situated in Hatton

How many dwellings are there?

Total number of dwellings in the building.

Total number of floors

To give you an appropriate quotation, would like to know the number of floors in your building.

Configuration of dwellings (no. of units per level)

To get an appropriate quotation and determine the kind of tests to be conducted, we will also need this.

Type of development

Knowing the kind of building is essential because it helps identify the type of test that will be conducted.

New Build or conversion project

These two go require different types performance, so let us know which one it is and you’ll get an accurate test and quotation.

Sound testing regulations

Get more credits for Code for Sustainable Homes and EcoHomes environmental assessment project by taking a sound insulation test which are aligned with approved document E building regulations rules.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

We can have fully accredited engineers sent to your property at your convenience to provide certification for Building Regulations Part E compliance, recognised by Building Control.

Standard division for developments (Scotland)

Section 5.1 of the Scottish Building Standards stipulates that “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be performed after construction, using the procedures given in annex 5.C. of the Scottish Standards. Standard 5.1 does not apply to: fully detached houses or roofs or walkways with access solely for maintenance, or solely for the use of the residents of the dwelling below.

How Do I Pass a Sound Insulation Test?

Make sure you pass your sound test by having efficient sound insulation included in the building design. It saves time and money and helps you avoid repair work and re-test expenses. Are you uncertain that the separating floor and walls you will build will adhere to Document E 2003 conditions? You can book our design services. Whether you want some initial tests on your project, or comprehensive reports at the end, we can help you at the level that you need. The following criteria should be followed to provide you with the best chance of passing your sound test: Install and make sure that all external and internal doors and windows are operational Fit and seal skirting boards Fix all light switches, light fittings and plug sockets. Our professional acoustic professionals work with contractors, architects, developers, and planner from the beginning of the design to make sure that all requirements are met.

Certificates for test evaluation and report

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern. A full report and individual sound test certificates can be generated and sent out usually the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The way the results look

A certificate will be issued to you whether the sound insulation treatment of the building meets the requirements of Document E of Building Regulations or not. In the event that some part of the building does not meet up with the conditions of Document E, remedial work and a retest is required. We give remedial design advice to help you achieve Building Regulations standards.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed