The measurement of the sound reduced by partitions in a development, such as a wall or floor, is known as sound insulation testing or sound testing. It assesses how good the soundproofing materials fixed to the property development are. The Building Regulations Approved Document E (ADE) states all new dwellings and renovated constructions should undergo sound testing.

Building Control does not issue completion certificates to buildings that don’t have a sound insulation certificate. Contractors and developers have sometimes discovered this, to their detriment. The significance of a sound insulation certificate cannot be overrated. Therefore, we ensure that you get the certificate speedily. In fact, we are proud of our turnaround times and our team will issue your certificates as quickly as we possibly can.

AF Acoustics’ competent and well-trained engineers, who will be available for testing, can even let you know the verbal results of your sound test. You will receive a written report in the space of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Insulation Test?

To adhere to Building Regulations ADE requirements, adjoining walls, floors and ceilings in a building will have to be tested, except where licensed Robust Details were used. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

What is involved in a Sound Test

The sound test itself produces very high levels of noise but also requires relatively quiet conditions on site. For these reasons, any workforce in the testing area will have to leave temporarily to ensure test accuracy. Sound insulation testing varies by size, complexity and conditions of site tested. A dwelling or development of normal size and simplicity will more than likely be tested in 90 minutes.

Once this is done, the sound test engineers give temporary results while they’re still on the site. They will also provide suggested solutions to possible problem areas noted during testing.

The entire report and individual sound test certificate will be sent to you the day after. Every 10 units in a group or sub-group are to be tested, according to ADE. A sub-group is stipulated in Section 1. Of ADE ADE also states the categories of developments that should be tested. There are three: rooms, flats and houses (including bungalows) that are lived in. Examples are student accommodation, hotel rooms and care homes. Find below the testing stipulation for each kind of development.

Why is Sound Insulation Testing Relevant?

After the 2003, Approved Document E mandates that all new structures in UK must take a sound insulation test before completion. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. This is to be certain that all new developments meet a uniform minimum criterion for resistance to sound from other parts of the development and adjoining developments. When sound resistance is high in party walls and floors, the environment is more comfortable, since sound affects every aspect of our lives – work environment, home environment and while relaxing. This is why sound testing is crucial.

Sound insulation and speech privacy are important because not having them results in an unfavourable environment for those living in the development. For example, in a block of flats, your upstairs neighbour may (and not unreasonably) like to have friends over at the weekend, resulting in the playing of loud music. However, the downstairs occupant may be working nights and sleeping throughout the day, thus any inadequate sound insulation between these two flats would cause great disturbance and distress to the downstairs occupant. Sound insulation helps improve the quality of a person’s life in diverse ways. Sound insulation is also effective in buildings that have flats with mixed uses. If the building passed the sound test, you can be sure that noise reduction will be effective.

Do I Need a Sound Insulation Test?

You need sound insulation testing if you:

  • Build a new development of 2 or more dwellings / flats
  • Convert a former single dwelling into flats
  • Build a Nursing Home or rooms for residential use, i.e. hotel or hostel
  • Have designs which do not adhere to Robust Details

Building Regulations Part E discusses sound testing in detail and has made it a requirement.

All you have to do is follow the guidelines listed in the document or pay to use Robust Details and you will have fulfilled the requirements. If you choose the latter, you must use Robust Details which are a approved design details for partitioning walls and floors. You also cannot expand or tweak the design from the Robust Detail Approved listing. However, you are exempt from the sound test. Being able to adapt your design to suit your needs is more efficient and costs less in the long run. It also gives architects the opportunity to evaluate their design and give your structure a much better sound insulation which will increase sound performance.

Price for Sound Insulation Testing

Contact us and we’ll give you a free quote on the sound test cost based on the requirements of your building. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

When can I carry out the sound insulation tests?

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. To be able to conduct sound insulation testing we require the provision of a 240V power supply, and a quiet site (a noisy site can make conducting the tests extremely difficult). Access will be required to all rooms of the development unless a test schedule is determined in advance.

How is Sound Insulation Testing Done?

Sound insulation testing is not complicated. Our highly qualified engineers will be willing to explain it in detail on the site. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

The test uses a dodecahedron speaker and pink or white noise generator for source sound. The sound source is placed in the largest room of the two. A sound level meter calculates the noise in the source room and receiver room. Background sound is also calculated. Noise in the receiver room should be 10dB more than the background noise at all frequency measurements, so source noise is set to be greater than background noise. For airborne sound tests, two individual speaker positions are used for each source room. Measurements are then made to determine the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

This basic level difference is then ‘corrected’ to allow for the reverberation time (the time is taken, in seconds, for a noise source to decay by 60dB) and the existing levels of background noise monitored whilst in the receiving room. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. Noise level in the room below is measured at various different frequencies. This is used in calculating and computing the results. These results are checked against Building Regulations ADE conditions for that kind of dwelling. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Kind of Testing Equipments Used

Our licensed engineers use UKAS calibrated equipment to measure sound insulation according to the present standards of Building Regulations. The calculation of the level of noise transmitted through the air between two adjoining units is known as an airborne sound insulation test. Equipment used for the test include a noise generator, speakers and sound level meter. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. The tests are carried out in rooms suitable for residential use like bedrooms, lounges and kitchens. Test results, which are approved by Building Control and used to sign off the building, are recorded in a report and sent to the client.

These kinds of properties should undergo a sound insulation test:

Sound testing measures the impact and airborne sound moving through new and old adjoining buildings. This could affect the separating walls between buildings or in-between the spaces in a development.

A new building with not less than two rooms

With the sound test, you can be certain that the property has a good acoustic performance.

Conversions of former single dwelling properties into flats

All the units that have been built are to be constructed in alignment with Part E of Building Regulations.

Design that don’t have Robust Details factored in

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the design does not completely follow Robust Details, sound insulation testing will occur to be certain the building meets ADE criteria. The minimum requirements during testing will depend on a variety of factors such as if the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

Which areas of the UK does AF Acoustics cover?

AF Acoustics renders acoustics design services and consultancy to customers all over the UK, especially in Maida-Vale. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.

Why choose AF Acoustics for Sound Insulation Testing?

Having rendered high quality service to numerous customers in Maida-Vale, we have gotten great positive feedback and recommendation from our clientele due to the following:

15 years’ experience

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. We also have a track record of providing superior acoustic services to our customers (home and business owners) in the UK in small and large projects, giving them astounding value for their money.

Great prices

To make sure you can afford high quality sound insulation projects in UK, we offer one of the most affordable prices in Maida-Vale. Contact us immediately and we’ll give you a free quote on the sound test.

Consultancy that is effective and efficient

Our expert acoustic advice is tailored to your specific needs based on our experience which enable us to provide strong solutions. We will give you the right answers and expert guidance so that you can get effectual solutions to your problems.

Adjustable test dates

Our test date options let you pick what will suit your schedule because your comfort is essential to us. If you want to schedule sound insulation testing in Maida-Vale, phone or email us immediately.

Get your test reports quickly

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. That way, you can take immediate action on the recommendations given. Our reports are thorough and cover all the important issues.

Sound insulation services we provide

AF Acoustics offer a variety of complete acoustic slutions to clients all over the Uk, Phone or email us today for more information on how we can help you with your acoustic requirements.

Airborne and impact tests for floors/ceilings

The ceilings/floors of developments undergo impact and airborne floor testing. An impact test measures the levels of noise transmitted directly through a separating construction. These floors in habitable rooms of flats undergo both impact and airborne tests.

Approved Document E test

Document E of Building Regulations requires certain criteria for the sound performance of a dwelling. Our sound insulation tests are conducted in accordance to these criteria. For new buildings, results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. Converted structures expected impact sound results increases by 2dB L’nTw while the airborne sound results reduces by 2dB DnTw+Ctr.

Sound test

We want to give our customers the most highest chance to acquire a pass and via our offer skilled services. In new build properties an airborne test or an airborne and impact test may be required to ensure it meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. To find out more about our sound testing services and get a free quotation, contact us now.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) describes the minimum requirement for the acoustics of a school building. It also stipulates how a school can conform to Building Regulations. If building a new school in Maida-Vale, we can test the school to check if it meets the requirements of BB93.

Acoustic plan

We provide acoustic layout services and consultancy for a huge range of building types and sizes. Our experience and expertise enables us to create bespoke solutions and understand diverse acoustic products. As a result, we’re able to provide targeted solutions to the demands of the project.

As anybody who has needed to handle the acoustics for a building will know, it’s essential to get proper advice, early in the project from a good acoustic expert. AF Acoustics can help you with identifying the right acoustic needs and standard for your construction at the beginning period and advise you on how to meet them.

We can assist with:

Acoustic detail layout for architect developing structures complying to Building regulations, BS8233 and so on. Detail plans for the educational, commercial and healthcare industry so as to meet with the current criteria. Specifications and building services design for control of noise in noise sensitive areas. Public address and sound reinforcement (conference rooms / lecture theatres etc.)

Get a sound insulation testing quotation by contacting our experts

At AF Acoustics, we are an independent acoustic consultancy. Our work embraces acoustic surveys, acoustic design and investigation work in the fields of planning and noise, architectural and building acoustics, the monitoring and control of vibrations and air tightness testing. Whether you are a company or a private individual, we are here to advise and guide you. If you would like a friendly and accurate sound insulation testing quote, please send an email to info@af-acoustics.com or give us a call.

020 3372 4430 Contact us

We would like to know the following

Give us the following information when contacting us

The development’s location

Where is your development situated in Maida-Vale

Number of dwellings in the building

Tell us how many dwellings you have in the property.

Number of floors in the building

To give you an appropriate quotation, would like to know the number of floors in your building.

Dwellings configuration per floor

This will also be needed to determine scope of the testing and provide an accurate quote

Types of construction

What is your building type? This will help us know the kind of test it will undergo.

New property or reconstructed dwelling

These two go require different types performance, so let us know which one it is and you’ll get an accurate test and quotation.

Building regulations for sound insulation test

We undertake sound insulation test on various buildings that adhere to Building Regulations Document E. Testing can also enable you get more credits for Code for Sustainable Homes and EcoHomes environmental assessment constructions.

Building regulations document E resistance to the passage of sound (England and Wales)

Our certified engineers can come to your building whenever it might suit you to undertake sound insulation testing to Part E of Building Regulations adherence, recognised by Building Control.

Building Standards Division (Scotland)

Section 5.1 of the Scottish Building Standards explicitly describes expected energy performance of dwellings. It states, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” The following are exempt from the testing techniques given in annex 5.C. of the Scottish Standard and Standard 5.1 – completely segregated rooftops, houses or walkways whose access is only used for upkeep or for the utilization of the inhabitants of the dwelling beneath.

How to get a pass certificate for your sound test

The most efficient way to make sure you pass sound insulation test is to have a plan that puts sound insulation into consideration from the begining. You don’t have to spend too much for this and it will save you money in the long run, ensuring you don’t pay remedial or re-test expenses. We offer design services to enable separating walls and floors with good sound insulation to meet the requirements of ADE, 2003. Whether you want some initial tests on your project, or comprehensive reports at the end, we can help you at the level that you need. The following will give you a better chance of passing the sound test: Inner and outer doors and windows have been installed and can be used Fit and seal skirting boards Light switches, plug sockets, and light fittings are adequately fixed. Our professional acoustic professionals work with contractors, architects, developers, and planner from the beginning of the design to make sure that all requirements are met.

Test report certificates

To get details of the results of a completed sound insulation test, we will provide you with an analysis and report certificate. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

How the results are

A sound insulation certificate will be sent to you whether the property has a good sound performance in accordance with ADE or not. In the event that some part of the building does not meet up with the conditions of Document E, remedial work and a retest is required. We give remedial design advice to help you achieve Building Regulations standards.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed