Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. It is compulsory for new buildings and refurbishment projects, according to Approved Document E (ADE) updated in 2003.

As many contractors and developers have found to their detriment, without a sound insulation certificate, the Building Control Officer will not issue a completion certificate. We know how important a sound insulation certificate is to you. That is why we work hard to make certain that you get the certificate quickly. In fact, we pride ourselves on issuing our sound insulation testing certificates as quickly as possible.

Our fully trained sound insulation test engineers can be on site when you need them. Your AF Acoustics engineer will give you immediate verbal results from the sound test, and you can will have a written report by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Test?

To completely fulfil Building Regulations Part E requirements, the separating walls and floors of dwellings will be tested, unless approved Robust Details are used. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

The Procedures Involved in a Sound Insulation Test

Workers on a site will vacate the premises while the sound test is being conducted. This will facilitate an enabling and quiet environment for the tests to be carried out. Undertaking sound tests on site varies according to the size and complexity of the building project and the site conditions. Most of the time the test will be conducted in 90 minutes, for a simple, regular sized construction.

The sound testing engineers then proceed to give verbal results on the site and offer helpful advice on any problem areas noticed during the duration of the test.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). Buildings to be tested are categorised into three kinds: houses, flats and rooms like care homes, student accommodation and hotel rooms. How much testing that should be done on each group is listed below:

Why Sound Testing is Required

Before completing a building, all new constructions should be tested for sound insulation, as stipulated by Approved Document E since 2003. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result. The aim of Approved Documet E of the Building Regulations is to establish a minimum standard for the reduction in noise levels between all dwellings in a new or refurbished building. When sound resistance is high in party walls and floors, the environment is more comfortable, since sound affects every aspect of our lives – work environment, home environment and while relaxing. This is why sound testing is crucial.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. For instance, in an apartment building, the neighbour upstairs might invite friends over during the weekend and put on loud music. The inhabitant downstairs might spend night hours as work time. If the sound insulation is inefficient, this could lead to lots of problems. This is just one instance of the influence of sound insulation on our lives. Sound insulation is also effective in buildings that have flats with mixed uses. If the building passed the sound test, you can be sure that noise reduction will be effective.

How to Know if You Need Sound Insulation Testing

Your development needs a sound insulation test if it meets one of the following criteria:

  • It’s design does not have Robust Details
  • It’s a new building with 2 or more dwellings
  • It’s being constructed to be used as a residence, like a hotel room or a hostel, or as a nursing home
  • It was once a single dwelling but is being turned into a development with several flats or units.

Document E of the Building Regulations explains sound insulation testing and makes it a necessity.

To conform, you can either follow the procedure outlined in ADE or make use of Robust Details. Robust Details are a set of specific design details for walls and floors that have been previously tested to show compliance and must be used if this route is selected. When you use it, you don’t have to take a sound insulation test. However, you must abide strictly by the design from the Robust Details approved list. With sound testing, however, you’re free to pick from any design, including more cost effective and appropriate ones. This makes it a more efficient process than Robust Details. Sound insulation testing can also help architects enhance their building design and in turn the sound insulation of the building.

How Much Will I Pay for a Sound Insulation Test?

To get a free quote for your dwelling, contact us. Not only are we highly experienced in providing sound testing services in UK, our reports and certificates get to the client within one of the fastest turnaround time and our prices are competitive. Send us a price you got that’s better than our and we will try to beat it.

When Should the Sound Tests be done?

Ideally, we would conduct a test when a development nears completion, and once all internal and external doors and windows have been fitted. We can test earlier to check if there are any problems. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

The Procedures of a Sound Insulation Test

Sound insulation testing is not complicated. Our highly qualified engineers will be willing to explain it in detail on the site. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

A pink or white noise generator and a large speaker is used for the test in the biggest room between the two undergoing testing. The sound generated and received is measured with a sound level meter. The meter is also used to measure the background sound, to ensure that it’s 10dB lower than the source sound, as is the standard. More background sound leads to creating a higher source sound. Airborne sound tests are conducted in this manner: two singular speaker positions are used for every source room. The noise in the receiver room is measured to determine the variations in noise level between the source and receiver room.

This basic level difference is then ‘corrected’ to allow for the reverberation time (the time is taken, in seconds, for a noise source to decay by 60dB) and the existing levels of background noise monitored whilst in the receiving room. Impact tests are carried out by means of a tapping machine placed on the floor to be measured. The room under it is then measured for the noise levels. This is used in calculating and computing the results. These results are checked against Building Regulations ADE conditions for that kind of dwelling. Of course, this is a simple way of describing the procedure followed when a sound test is carried out, but it enables you to understand it better.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Testing Equipment to Expect

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. Airborne sound test is the measurement of sound moving through the air through a wall or floor. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. A sound level meter and a tapping machine which drops metal hammers is used for impact testing. Testing is done on rooms that can be lived in. E.g. lounges, kitchens, bedrooms and living rooms. Test findings are compiled in a report and issued to the client. The report will be accepted by Building Control and used for signing off your project.

Sound insulation testing is essential for these dwelling types:

Sound testing measures the impact and airborne sound moving through new and old adjoining buildings. This could affect the separating walls between buildings or in-between the spaces in a development.

A new building with not less than two rooms

This makes certain that the dwellings have adequate sound proofing.

Converting a property into several units

The development that has been converted must conform to Building Regulations sound requirements.

Designs without Robust Details

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. A building built as a permanent dwelling has different minimum standards from a building with rooms built for residential purpose, like a hotel or a hostel.

Which areas of the UK does AF Acoustics cover?

As an acoustics design services firm, AF Acoustics provides acoustic consultancy to various individuals and businesses nationwide, especially in Northwood-Hills. We work with architects, planning and environmental consultancies as well as private individuals and government agencies. We’re based in several areas across the south east region of UK so that we can give you the most cost effective quote in the industry.

Why you should choose AF Acoustics

Having rendered high quality service to numerous customers in Northwood-Hills, we have gotten great positive feedback and recommendation from our clientele due to the following:

More than 15 years’ experience

We understand the industries our clients are in. Therefore, we provide advice that is technically adequate, useful and applicable. We also have a track record of providing superior acoustic services to our customers (home and business owners) in the UK in small and large projects, giving them astounding value for their money.

Affordably rates

To ensure all clients in Northwood-Hills can afford superior quality sound insulation testing, we offer some of the most competitive rates you can both in and outside Northwood-Hills. If in doubt, contact us now for a free no-obligation quote.

Ultrafast and efficient consultancy

We will listen to your wishes, provide you sturdy solutions and deliver acoustic consultancy through our expertise. Both your short and long-term needs are handled with our professional guidance and quick answers to your problems.

Flexible test dates

Our test date options let you pick what will suit your schedule because your comfort is essential to us. Call us now to schedule sound insulation testing in Northwood-Hills

Fast turnaround for your report

When you get your sound test report fast, you’re able to take corrective action. We try to issue reports on the next working day no matter how large or complex the project. The delivered report will be comprehensive and well detailed to ensure all relevant issues are covered and any recommendations are provided.

The sound testing services we provide

With AF Acoustics, you get a highly effective and expert acoustic advice which our customers all over UK have benefited from. Call or mail us today so we can provide you with more knowledge on your acoustics needs.

Impact and airborne tests for floors

These are taken on separating floors/ceilings between residences. The measurement of the extent of noise transmitted directly through impact from one adjoining room to another is known as impact testing. Impact and airborne testing is undertaken between party floors.

Approved Document E test

AF Acoustics sound testing adheres to ADE which stipulates information bearing on the sound resistance and performance of a property. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw for new structures. Converted properties get a slightly different requirement. Expected minimum airborne sound insulation test result is 43dB DnTw+Ctr while expected maximum impact sound test result is 64dB L’nTw.

Sound Insulation Testing

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. In new properties, an airborne and impact test will help you guarantee the building meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We frequently give robust advice to project managers and developers from the start of the construction, ensuring that they’ll have adequate sound insulation to pass a sound test. Simply contact us immediately ad you’ll get a free quotation in addition to more details about our sound testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Acoustic design testing in schools in line with BB93

Building Bulletin 93 (BB93) explains the sound performance requirement for the acoustics of school buildings. It likewise states how a school can meet this requirement. Are you building a new school in Northwood-Hills? Contact us to arrange a sound test and make sure it meets the benchmarks of BB93.

Acoustic design details

AF Acoustics provide detailed acoustic design services and consulting on a wide range of buildings. We have the capability and experience to develop customised solutions, and have a strong working knowledge of available proprietary acoustic products. We will develop detailed design solutions suitable for the specific demands of the project.

Getting advice on the acoustics of a development as early as possible is crucial. AF Acoustics can enable you to do that by advising you on the appropriate acoustic requirements of your property very early in the building process and recommending what to do to fulfil them.

We can help with:

Creating acoustic detail plans for architects involved in residential construction that conform to Document E of Building Regulations, BS8233 and so on. Detail plans for the educational, commercial and healthcare industry so as to meet with the current criteria. Specifications and building services design for control of noise in noise sensitive areas. Improving sound and public address system in halls, conference rooms etc.

To get a sound test quote for your building, call or email our highly skilled professionals

Our services at AF Acoustics include acoustic design and investigation, evaluation and calculation of noise, acoustic survey, building an architectural acoustics and air pressure testing. Our expert consultation is available to individuals and companies with all types and sizes of constructions. We will give you free quotation with highly competitive rates. Simply call us or email info@af-acoustics.com

020 3372 4430 Contact us

Giving the following information to us will be helpful

When contacting us for sound insulation testing quote, we will need you to provide the following information

Construction’s location

Where is your development situated in Northwood-Hills

Number of dwellings in the building

Total number of dwellings in the structure

How many storeys are there?

For the right calculation of your quotation, tell us how many levels are in your building.

Configuration of dwellings (no. of units per level)

How many units are on each floor? Knowing this will help us give you an appropriate quotation.

Types of construction

The type of building, as different building types typically require a different testing.

New property or reconstructed dwelling

Knowing if your building is new or converted allows us to give you a competitive quotation and prepare the right test for it.

Sounds test in accordance with building regulations

We undertake sound insulation test on various buildings that adhere to Building Regulations Document E. Testing can also enable you get more credits for Code for Sustainable Homes and EcoHomes environmental assessment constructions.

Sound resistance: approved document of building regulations (England and Wales)

Our expert engineers can issue certificates for the sound insulation testing. They can visit the site and conduct the test that will lead to getting a certificate which is in line with Building Regulations and Building Control requirements.

Scotland Standard division for completed constructions

Section 5.1 of the Scottish Building Standards explicitly describes expected energy performance of dwellings. It states, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Fully detached roofs or walkways that are not used for residential purposes do not have to take the sound tests of the Scottish Standards 5.1.

How to make sure you pass your sound test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. If you are unsure of how to build the separating floor and wall constructions and associated junctions across your development to satisfy the requirements of Document E 2003, we can offer design advice. We can study design reports, complete site visits and sound test the development to provide you with the level of assessment and consultation that your project requires from start to finish. The following criteria should be followed to provide you with the best chance of passing your sound test: All windows and door have been fixed and are functioning Fit and seal skirting boards Fix all light switches, light fittings and plug sockets. Our accomplished acoustic consultants work with developers, planners, contractors, and architects of all sizes from the early stages of the building plan to help limit any potential sound insulation performance problems to the completion of the construction, guaranteeing that all properties meet the criteria of Building Regulations Document E 2003.

Analysis and Report Certificates

To obtain a thorough evaluation of your building, we issue a report certificate within 24 working hours where possible. Our highly capable sound test engineers will give you a verbal result of the test, once the test is taken and proffer solutions to possible problems or future areas of concern. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The results

A sound insulation certificate will be sent to you whether the property has a good sound performance in accordance with ADE or not. If a partition wall or floor does not comply with Part E standards, repair work and another sound test will be needed. We can give robust advice on that to ensure you pass.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed