The measurement of the sound reduced by partitions in a development, such as a wall or floor, is known as sound insulation testing or sound testing. It assesses how good the soundproofing materials fixed to the property development are. The Building Regulations Approved Document E (ADE) states all new dwellings and renovated constructions should undergo sound testing.

Not doing so is a costly venture for developers and contractors as Building Control will not give a completion certificate for developments that have not undergone the test. The significance of a sound insulation certificate cannot be overrated. Therefore, we ensure that you get the certificate speedily. We take great pride in providing our certificates to you as soon as possible after the tests.

Our fully trained sound insulation test engineers can be on site when you need them. Your AF Acoustics engineer will give you immediate verbal results from the sound test, and you can will have a written report by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Insulation Test?

In order to comply with Part E of the Building Regulations, developments will require the testing of separating walls and floors. The only exception is where Robust Details have been used. The airborne and impact sound going through new and old structures are evaluated by sound testing. This can impact adjoining walls and floors between the structures.

What is involved in Sound testing?

The sound test itself produces very high levels of noise but also requires relatively quiet conditions on site. For these reasons, any workforce in the testing area will have to leave temporarily to ensure test accuracy. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. Generally, a sound insulation test takes about 90 minutes for a simple, regular sized project.

Once this is done, the sound test engineers give temporary results while they’re still on the site. They will also provide suggested solutions to possible problem areas noted during testing.

You will get a detailed written report and sound test certificate about a day after, if possible. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. The volume of testing carried out on each group is written below.

Why Should Your Dwelling Undergo Sound Testing

Sound insulation testing is required because ADE of Building Regulations has made it compulsory for all new buildings to take a sound test prior to finishing construction. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. These result limits were put in to create and maintain a uniform standard for sound resistance in different parts of a dwelling and between adjacent buildings. Sound insulation testing is important because sound affects the way we live, whether at work, in the home or whilst at leisure. Noise reduction between walls and floors could result in a more comfortable, productive environment.

Insufficient sound insulation causes distress and comfort while an effective sound insulation system brings about speech privacy. This is one of the several reasons why sound insulation is a key element in building. Let’s take a look at this scenario. An individual living in a block of flats might spend the weekend with friends relaxing and playing loud music. If the sound insulation on adjoining walls and floor is insufficient, the music will be distressful to neighbours, especially if they work at night. Sound insulation impacts people’s lives in various ways. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

Do I Need a Sound Insulation Test?

Your development needs a sound insulation test if it meets one of the following criteria:

  • It’s design does not have Robust Details
  • It’s a new building with 2 or more dwellings
  • It’s being constructed to be used as a residence, like a hotel room or a hostel, or as a nursing home
  • It was once a single dwelling but is being turned into a development with several flats or units.

Sound insulation is covered and made mandatory under Approved Document E of The Building Regulations.

All you have to do is follow the guidelines listed in the document or pay to use Robust Details and you will have fulfilled the requirements. If you choose the latter, you must use Robust Details which are a approved design details for partitioning walls and floors. When you use it, you don’t have to take a sound insulation test. However, you must abide strictly by the design from the Robust Details approved list. Being able to adapt your design to suit your needs is more efficient and costs less in the long run. Conducting on-site pre-completion sound testing also enables the architects more scope with their design and can lead to improved sound insulation performance.

How much does sound insulation testing cost?

We can send quotation that’s completely free of charge and is based on the kind of development you have. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

Period Sound Insulation Test Should be Carried Out

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

The Procedures of a Sound Insulation Test

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. For partition walls, airborne tests are carried out. For floors there are two types, airborne and impact tests.

The airborne sound insulation test is carried out with a large speaker or dodecahedron speaker, using a white or pink noise generator to create the source sound, almost always in the largest room of the two rooms under testing. A sound level meter calculates the noise in the source room and receiver room. Background sound is also calculated. Noise in the receiver room should be 10dB more than the background noise at all frequency measurements, so source noise is set to be greater than background noise. For airborne sound tests, two individual speaker positions are used for each source room. Measurements are then made to determine the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact tests are carried out by means of a tapping machine placed on the floor to be measured. Noise level in the room below is measured at various different frequencies. This is used in calculating and computing the results. These results are checked against Building Regulations ADE conditions for that kind of dwelling. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. An airborne sound test measures levels of sound transmitted through the air through a separating element. The equipment we use are a sound level meter, loudspeaker and white or pink noise generator. Sound level meter is also used for impact tests. Alongside it, a tapping machine that drops metal hammers is used. Testing is done on rooms that can be lived in. E.g. lounges, kitchens, bedrooms and living rooms. Test results, which are approved by Building Control and used to sign off the building, are recorded in a report and sent to the client.

A sound test is mandatory for these buildings:

Sound Insulation Testing checks for both airborne and impact noise travelling through new or existing buildings. This may affect party walls and floors between new and existing buildings, or between spaces within a new development.

Two or more new build dwellings or flats

With the sound test, you can be certain that the property has a good acoustic performance.

Redevelopment of a building with a single dwelling into flats

All the units that have been built are to be constructed in alignment with Part E of Building Regulations.

Design not using Robust Details

The Robust Detail Scheme, set up in 2004 by Robust Details Ltd, architects create design details for walls and floors that were tested formerly for sound insulation and meet the sound performance parameters stated by Part E of Building Regulations. If the building design is slightly different from Robust Details, a sound test is essential so that Building Regulations criteria can be met. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Areas in the UK AF Acoustics Conduct Test

AF Acoustics provides acoustic design services to customer nationwide, especially in Redbridge. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. You can find our consultants all over the south east region of the country. That way we give you the most affordable quotation that will meet your budget needs.

Why AF Acoustics is the right choice for your sound insulation test

We have worked with many organisations and individuals in Redbridge. Our clients have endorsed us for the following reasons:

Sound testing experience of over 15 years

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. By doing this, we have been able to continuously satisfy clients in the UK and meet their acoustic needs for over 15 years, providing great value for money.

Affordably rates

Compared to other sound insulation testing service in Redbridge, our prices are extremely competitive. This is because we want you to be able to afford the best expert sound testing service there is. To get a free quote for your dwelling, contact us today.

Fast and efficient consultancy

Our expert acoustic advice is tailored to your specific needs based on our experience which enable us to provide strong solutions. Both your short and long-term needs are handled with our professional guidance and quick answers to your problems.

Adaptable test dates

Our test date options let you pick what will suit your schedule because your comfort is essential to us. Call us now to schedule sound insulation testing in Redbridge

Test reports arrive the next day

The sooner you get a report on the completed sound insulation test, the sooner you can take appropriate action. We strive to deliver next day reporting in all scenarios regardless of the complexity or size of the project. That way, you can take immediate action on the recommendations given. Our reports are thorough and cover all the important issues.

Sound insulation testing services AF Acoustics undertake

AF Acoustics offer a range of comprehensive acoustic solutions to customers nationwide, and we guarantee a high-quality and high-efficiency approach. Telephone or email us today for more data on how we can assist you with your acoustic requirements.

Airborne and impact ceilings/floor tests

Impact and airborne floor tests are conducted on ceilings/floors between rooms. The measurement of the extent of noise transmitted directly through impact from one adjoining room to another is known as impact testing. These floors in habitable rooms of flats undergo both impact and airborne tests.

PART E Testing

AF Acoustics sound testing adheres to ADE which stipulates information bearing on the sound resistance and performance of a property. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw for new structures. Converted properties get a slightly different requirement. Expected minimum airborne sound insulation test result is 43dB DnTw+Ctr while expected maximum impact sound test result is 64dB L’nTw.

Testing for sound insulation

Our services and expertise is unbeatable and we are glad to work with our clients to help pass their sound insulation tests. In new properties, an airborne and impact test will help you guarantee the building meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Simply contact us immediately ad you’ll get a free quotation in addition to more details about our sound testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 testing of acoustic design in schools

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. If building a new school in Redbridge, we can test the school to check if it meets the requirements of BB93.

Acoustic design details

AF Acoustics provide extensive design services and consultancy on a variety of buildings. We have the ability and experience to create bespoke solutions, and have solid working information of accessible acoustic items. We will create design solutions appropriate for the explicit requests of the construction.

It is critical to get right professional assistance ahead of schedule from a highly qualified acoustic specialist. AF Acoustics can assist you with identifying the right acoustic propertiesfor your project at very early on in the construction process and tell you the best way to get them, utilizing a deep know-how of acoustic design.

We are able to help with:

Acoustic detail design for architects involved in residential developments for compliance with Part E Regs, BS8233, and so on. Detail layout for the commercial, health and educational constructions in order to align with regulations. Construction designs and specifications for sound control in residential areas and other noise sensitive developments. Public address and sound reinforcement system

Call Our Experts Now For A Sound Insulation Testing Quote

We are an independent acoustic organisation that handles everything concerning acoustics including survey, design, architectural and building acoustics and air tightness testing. We will give you sound advice and guidance no matter who you are or the kind of project you have. To get an accurate quotation, either call us or email info@af-acoustics.com

020 3372 4430 Contact us

Giving the following information to us will be helpful

In your email or during your phone call, tell us about the following

Location of property

Provide the location of your building in Redbridge.

How many dwellings are there?

Total number of dwellings in the building.

Total number of floors

Let us know the number of floors in your development so that we can give you an accurate quotation.

Number of dwelling units per storey

To help us get you an accurate quotation and evaluate the scope of the test to be taken, tell us how many dwellings there are per floor.

Building type

What is your building type? This will help us know the kind of test it will undergo.

New property or reconstructed dwelling

Knowing if your building is new or converted allows us to give you a competitive quotation and prepare the right test for it.

Sound Insulation Testing Regulations

Our ADE compliant sound tests can help you gain credits for Code for Sustainable Homes and EcoHomes environmental assessment structures.

Part E of building regulations resistance to the passage of sound (England and Wales)

Our certified engineers can come to your building whenever it might suit you to undertake sound insulation testing to Part E of Building Regulations adherence, recognised by Building Control.

Scotland Standard division for completed constructions

Section 5.1 of the Scottish Building Standards states “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” The following are exempt from the testing techniques given in annex 5.C. of the Scottish Standard and Standard 5.1 – completely segregated rooftops, houses or walkways whose access is only used for upkeep or for the utilization of the inhabitants of the dwelling beneath.

How to pass a sound test

Make sure you pass your sound test by having efficient sound insulation included in the building design. It saves time and money and helps you avoid repair work and re-test expenses. If you’re not certain of how to construct your party walls and floors, to meet Document E 2003 targets, simply contact us for an efficient design service. We can study design reports, complete site visits and sound test the development to provide you with the level of assessment and consultation that your project requires from start to finish. Take the following action to give your building the best opportunity to pass the sound insulation test: Windows and internal and external doors are fitted and operable Skirting boards are fitted and sealed Light fittings and switches and plug sockets are fitted and working. We work with several professionals in construction from the beginning of the design stage to the completion of the development to make certain it conforms to Document E 2003 of Building Regulations.

Test report certificates

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern. A full report and individual sound test certificates can be generated and sent out usually the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What the results look like

A certificate will be issued to you whether the sound insulation treatment of the building meets the requirements of Document E of Building Regulations or not. If a partition wall or floor does not comply with Part E standards, repair work and another sound test will be needed. We can give robust advice on that to ensure you pass.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed