Sound insulation testing is used to measure the resistance of sound provided by an element of a building (such as a floor or wall) between dwellings. It essentially measures the effectiveness of the sound proofing treatment installed as part of a build or property development. New structures and reconstructed developments have been mandated by the Building Regulations to test for sound upon completion, since Approved Document E (ADE) was reappraised in 2003.

As many contractors and developers have found to their detriment, without a sound insulation certificate, the Building Control Officer will not issue a completion certificate. Because we understand how the sound insulation certificate affects your building project, we ensure that you get it as quickly as possible after the test. When the tests are completed, we work quickly to issue your certificates; we take great pride in our efficiency.

AF Acoustics’ competent and well-trained engineers, who will be available for testing, can even let you know the verbal results of your sound test. You will receive a written report in the space of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Insulation Test?

To completely fulfil Building Regulations Part E requirements, the separating walls and floors of dwellings will be tested, unless approved Robust Details are used. The airborne and impact sound going through new and old structures are evaluated by sound testing. This can impact adjoining walls and floors between the structures.

What is part of a Sound Insulation Test

The sound test itself produces very high levels of noise but also requires relatively quiet conditions on site. For these reasons, any workforce in the testing area will have to leave temporarily to ensure test accuracy. The process of a sound test is determined by the size and complexity of the site being tested. A structure that is simple and the conventional size will usually take 90 minutes to be tested.

After the test, the sound insulation test engineers will let you know the outcome of the test and supply simple feedback of important things noted during the test; e.g. problems that might occur in the future.

A full and thorough report with the certificate of the test will be given to you within 24 working hours. The sound testing guidelines are stipulated in Building Regulations ADE. It requires one set of test to be conducted on 10 units in a group or sub-group. You can find out what is meant by a sub-group in Section 1 of ADE. ADE also states the categories of developments that should be tested. There are three: rooms, flats and houses (including bungalows) that are lived in. Examples are student accommodation, hotel rooms and care homes. How much testing that should be done on each group is listed below:

Why Should Your Dwelling Undergo Sound Testing

Sound insulation testing is required because ADE of Building Regulations has made it compulsory for all new buildings to take a sound test prior to finishing construction. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. This Approved Document, as part of UK Building Regulations helps to ensure that new buildings are constructed to minimum standards that provide reasonable resistance to sound from other parts of the same building and from adjacent buildings. Sound testing is essential due to the fact that sound impacts us wherever we are, whether it’s at home, leisure or the office. Reduced noise in the partitions and flooring of a structure leads to greater ease and a more efficient environment.

Sound insulation and speech privacy are critical for a variety of reasons. Inadequate sound insulation can be extremely distressing to those affected by it. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. Sound insulation impacts people’s lives in various ways. In a structure with flats for mixed purposes, a sound insulation test will make sure that there is maximum sound resistance from party walls and floors and less noise.

How Do I Know if I Need a Sound Test?

Your development needs a sound insulation test if it meets one of the following criteria:

  • It’s design does not have Robust Details
  • It’s a new building with 2 or more dwellings
  • It’s being constructed to be used as a residence, like a hotel room or a hostel, or as a nursing home
  • It was once a single dwelling but is being turned into a development with several flats or units.

Building Regulations Part E discusses sound testing in detail and has made it a requirement.

To conform, you can either follow the procedure outlined in ADE or make use of Robust Details. Robust Details are a set of specific design details for walls and floors that have been previously tested to show compliance and must be used if this route is selected. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. Sound testing provides more flexibility by allowing different designs and is often therefore more cost effective in many ways compared to the Robust Details Scheme. It also gives architects the opportunity to evaluate their design and give your structure a much better sound insulation which will increase sound performance.

Price for Sound Insulation Testing

To get a free quote for your dwelling, contact us. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

Sound Insulation Test Time

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. For your sound tests to be conducted successfully we need the property to be quiet, with workers not near the rooms to be tested during the test time (a noisy environment makes the test difficult and sometimes unsuccessful). We also need access to all units unless the test program has been compiled earlier. Finally, we need 240V power supply.

How a Sound Test is Done

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. The separating walls undergo airborne tests while separating walls and floor undergo airborne and impact tests.

The test uses a dodecahedron speaker and pink or white noise generator for source sound. The sound source is placed in the largest room of the two. The noise from the source room and received by the receiver room, and background noise is measured with a sound level meter. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. Airborne sound tests are conducted in this manner: two singular speaker positions are used for every source room. The noise in the receiver room is measured to determine the variations in noise level between the source and receiver room.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact tests are conducted by fixing a tapping machine on the floor. The sound level in the room below it is recorded. Calculations are undertaken, and results achieved. The results are crosschecked to ensure they meet Document E of Building Regulations target. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Equipment do we use?

You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. An airborne sound test measures levels of sound transmitted through the air through a separating element. We use a loudspeaker and noise generator that produces white or pink noise on one side of the partition, and measure with a sound level meter on both sides to calculate the sound insulation performance of the partition. For impact test, a tapping machine that makes impact sound by dropping metal hammers is used. A sound level meter is used to measure in the receiving room below the room the tapping machine is in. Testing is done on rooms that can be lived in. E.g. lounges, kitchens, bedrooms and living rooms. You will get the test results in a report within a working day. This report can be used to help sign off your building as it is accepted by Building Control.

A sound test is mandatory for these buildings:

For sound testing we usually undertake impact and airborne sound test on buildings. This affects the separating floors and walls between habitable rooms of buildings and developments.

A new building with not less than two rooms

This makes certain that the dwellings have adequate sound proofing.

Conversions of former single dwelling properties into flats

The transformation of a single dwelling property into flats must adhere to the sound insulation standards of Building Regulations.

Design that don’t have Robust Details factored in

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the building design is slightly different from Robust Details, a sound test is essential so that Building Regulations criteria can be met. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Areas in the UK AF Acoustics Conduct Test

AF Acoustics is an acoustic consultancy providing acoustic design services to clients nationwide, especially in Sands-End. Af Acoustics work with individuals, government agencies, planning and environmental consultancies, and architects. We’re based in several strategic locations in the south east of UK to enable you get the best quotation and price possible.

Why AF Acoustics is the best choice for sound insulation testing

Our sound insulation testing expertise at AF Acoustics have aided several home and business owners in Sands-End. We come highly recommended by our clients because of the guarantees when you work with us

Over 15 years’ experience

With more than 15 years of experience, we have a deep knowledge of our customers’ industry and provide actionable strong advice tailored to their needs. By doing this, we have been able to continuously satisfy clients in the UK and meet their acoustic needs for over 15 years, providing great value for money.

Competitive rates

To make certain that all clients in Sands-End can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Sands-End. Contact us right now to get a quotation that’s completely free of charge.

Ultrafast and efficient consultancy

We will listen to your wishes, provide you sturdy solutions and deliver acoustic consultancy through our expertise. When you reach out to us for professional advice, we make certain that we render accurate solutions rapidly. We suggest productive answers that handle your present and long-term desires to the maximum.

Test dates that are flexible

Because your convenience is important to us, we provide several options to help you choose a test date that is best for you. If you want to schedule sound insulation testing in Sands-End, phone or email us immediately.

Get your test reports quickly

The sooner you receive the details of your sound insulation test results, the sooner you can get your building signed or remedy any problems. We endeavour to give you the report the following working day in all situations, even when the project is complex and large in size. We make certain all relevant issues are covered and quality tips are supplied by detailing all the aspects of the test in the report.

Sound insulation testing services AF Acoustics undertake

AF Acoustics offer a range of comprehensive acoustic solutions to customers nationwide, and we guarantee a high-quality and high-efficiency approach. Call or mail us today so we can provide you with more knowledge on your acoustics needs.

Impact and airborne tests for floors

These are performed on floors and/or ceilings between units. The calculation of the sound level transferred from one unit to another through a separating floor via impact is called an impact test. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

PART E Testing

Our sound tests align to Part E of Building Regulations guideline, which thoroughly describes sound resistance level and performance from structures. The impact sound test of new dwellings should be 62dB L’nTw or less and airborne sound insulation 45dB DnTw+Ctr or more while impact results for reconstructed properties should be 64dB L’nTw and airborne sound insulation 43dB DnTw+Ctr or more.

Sound testing

We want to give our customers the most highest chance to acquire a pass and via our offer skilled services. In new build properties an airborne test or an airborne and impact test may be required to ensure it meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Simply contact us immediately ad you’ll get a free quotation in addition to more details about our sound testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Acoustic design tests in schools in accordance with BB93

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. If building a new school in Sands-End, we can test the school to check if it meets the requirements of BB93.

Acoustic Design

AF Acoustics give definite design services and consultancy services to all types of developments. We create bespoke solution and can provide information on the best available acoustic products. We will tailor our design solutions to your project.

As anyone who has had to deal with the acoustic properties of a building will know, it’s important to get the correct advice, as early as possible from a good acoustic consultant. AF Acoustics can help you to identify the correct acoustic requirements for your project at an early stage and advise on the best means to meet them using expert knowledge of acoustic design.

We are able to help with:

Acoustic detail design for architects involved in residential developments for compliance with Part E Regs, BS8233, and so on. Detail plans in commercial, educational and healthcare project for adhering to the prescribed standard. Specifications and building services design for control of noise in noise sensitive areas. Public address and sound reinforcement (conference rooms / lecture theatres etc.)

Call Our Experts Now For A Sound Insulation Testing Quote

As an independent acoustics consultancy, AF Acoustics is able to provide extensive acoustic survey and design, investigations in the field of planning and noise, architectural and building acoustics, and air permeability testing. Our professional guidance and advice is provided to private individuals, businesses and government agencies amongst others. You can contact us by sending us an email on info@af-acoustics.com or calling us for a free quote.

020 3372 4430 Contact us

Giving the following information to us will be helpful

When calling or emailing us please provide the following data

Location of development

Where is your development situated in Sands-End

Number of dwellings in the building

Total number of dwellings in the building.

Total number of floors

To give you an appropriate quotation, would like to know the number of floors in your building.

Dwellings arrangements per level

To get an appropriate quotation and determine the kind of tests to be conducted, we will also need this.

Building type

Tell us the kind of property because different buildings require different amounts of tests.

New Build or conversion project

The testing requirements for new dwellings and converted properties are not the same. Tell us the type of building you have so that we give you the right quote.

Sound testing regulations

We provide sound testing and sound insulation testing on all types of buildings, for compliance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building Standards. Testing can also gain credits for Code for Sustainable Homes and EcoHomes environmental assessment schemes.

Resistance to the passage of sound: Approved Document E (England and Wales)

We have fully accredited engineers who can visit your property to issue appropriate certification that complies with the building control.

Standard division for developments (Scotland)

In the words of Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be performed after construction, using the procedures given in annex 5.C. of the Scottish Standards. Standard 5.1 does not apply to: fully detached houses or roofs or walkways with access solely for maintenance, or solely for the use of the residents of the dwelling below.

How to make sure you pass your sound test

The best method to guarantee you pass your sound test is to design the building with a view to good sound insulation performance. This shouldn’t be exorbitant, and can save time and cost at the end, without your having to correct sound problem or pay for a re-test. Are you uncertain that the separating floor and walls you will build will adhere to Document E 2003 conditions? You can book our design services. The degree of guidance you require can vary, from site visits and comprehensive design reports, to simpler initial testing to know the starting point for construction. Take the following action to give your building the best opportunity to pass the sound insulation test: Windows and internal and external doors are fitted and operable Skirting boards are fixed are sealed Light switches, light fittingsand plug sockets are properly fitted Our accomplished acoustic consultants work with developers, planners, contractors, and architects of all sizes from the early stages of the building plan to help limit any potential sound insulation performance problems to the completion of the construction, guaranteeing that all properties meet the criteria of Building Regulations Document E 2003.

Certificates for test evaluation and report

To get details of the results of a completed sound insulation test, we will provide you with an analysis and report certificate. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The way the results look

A sound insulation certificate will be sent to you whether the property has a good sound performance in accordance with ADE or not. In the event of a wall or floor not achieving the Part E requirements, it may be necessary to carry out remedial works before having another sound test carried out. We can provide you with remedial design advice to help you achieve the Building Regulations requirements.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.