Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. The Building Regulations Approved Document E (ADE) states all new dwellings and renovated constructions should undergo sound testing.

At the completion of the test, a sound insulation certificate is issued. Without the certificate, Building Control will not release the building completion certificate to the contractors and developers of the project. We know how important a sound insulation certificate is to you. That is why we work hard to make certain that you get the certificate quickly. We take great pride in providing our certificates to you as soon as possible after the tests.

Our fully trained sound insulation test engineers can be on site when you need them. Your AF Acoustics engineer will give you immediate verbal results from the sound test, and you can will have a written report by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Does

Walls and floors that separate dwellings in a building are expected to be sound tested, as mandated by Document E of Building Regulations. Only dwellings that have used Robust Details, which licensed before the installation, are exempted from the test. The airborne and impact sound going through new and old structures are evaluated by sound testing. This can impact adjoining walls and floors between the structures.

What is involved in a Sound Test

Even though sound insulation testing equipment produces lots of noise, sound testing requires quiet conditions and dwellings. Because of this, workers on the site would have to leave during the time of the test, to avoid errors in the test calculation. Undertaking sound tests on site varies according to the size and complexity of the building project and the site conditions. A structure that is simple and the conventional size will usually take 90 minutes to be tested.

Once it is completed, the engineers will give a verbal interim result on the site and basic helpful information on what was noticed during the test, e.g. possible sound issues and future places that could cause problems.

A full and thorough report with the certificate of the test will be given to you within 24 working hours. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). Buildings to be tested are categorised into three kinds: houses, flats and rooms like care homes, student accommodation and hotel rooms. Find below the testing stipulation for each kind of development.

Importance of Sound Insulation Testing

Before completing a building, all new constructions should be tested for sound insulation, as stipulated by Approved Document E since 2003. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. ADE ensures that new building are resistant to noise from adjoining buildings and other rooms within the same building. Sound affects our life no matter where we are, at home, work or while relaxing. Places with lowered noise are more comfortable and enabling. Sound testing ensures that noise reduction in a building is effective.

Sound insulation and having privacy while speaking are crucial for a number of reasons. When sound insulation is deficient, it can cause discomfort to occupants. Let’s take a look at this scenario. An individual living in a block of flats might spend the weekend with friends relaxing and playing loud music. If the sound insulation on adjoining walls and floor is insufficient, the music will be distressful to neighbours, especially if they work at night. This is just one instance of the influence of sound insulation on our lives. It can be useful in dwellings with neighbouring units/flats/rooms which have diverse purposes, by guaranteeing that an occupant in a room will hear as little noise as possible from the neighbouring room.

How Do I Know if I Need a Sound Test?

If you’re doing one of the following, then you need a sound test:

  • Constructing a building that has two or more units
  • Constructing a nursing home or rooms that will be lived in, e.g. hotel room or hostel
  • Converting a single development to flats
  • Using designs where Robust Details are not included

Building Regulations Part E discusses sound testing in detail and has made it a requirement.

To conform, you can either follow the procedure outlined in ADE or make use of Robust Details. Robust Details are design details for separating elements, which have been tested before to comply with Document E standards. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. Being able to adapt your design to suit your needs is more efficient and costs less in the long run. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.

Price for Sound Insulation Testing

Call us or email us to get a free quotation for your building. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

When can I carry out the sound insulation tests?

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. These are the things we need to conduct the test:

  • 240V power supply
  • A quiet environment
  • Access to all the units of the structure unless places to test have been decided before then.

How a Sound Test is Done

Sound testing procedure is quite simple and our engineers are happy to explain this on site. For partition walls, airborne tests are carried out. For floors there are two types, airborne and impact tests.

The test uses a dodecahedron speaker and pink or white noise generator for source sound. The sound source is placed in the largest room of the two. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. Noise in the background is also calculated. More noise in the background means a higher level of source sound will be created since it’s supposed to be 10dB higher than background noise on all calculated frequencies. When conducting airborne sound insulation tests, two speakers are placed in each source room. The noise level in the receiving room is measured to get the sound difference between the source and receiving room.

This difference is modified to include background noise in the receiver room and reverberation time – time whereby a sound fades away in a closed space by 60dB. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. Noise level in the room below is measured at various different frequencies. Calculations based on these measurements are undertaken and the results compared to the Building Regulations Part E requirements for the given type of the building. This is a simple way of explaining how a sound test is conducted.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Equipment do we use?

You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. An airborne test is used to check how much sound is moving through the air between partitions. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. Testing can only be completed on ‘habitable’ rooms. Habitable rooms can be bedrooms, lounges, living rooms and open plan kitchen/ living spaces. Test findings are compiled in a report and issued to the client. The report will be accepted by Building Control and used for signing off your project.

Sound Insulation Testing is necessary for these types of builds:

The airborne and impact sound going through new and old buildings are evaluated by sound testing. This can impact adjoining walls and floors between the building.

A structure with 2 or more units/flats

This is to ensure that the sound proofing of the building is up to standard for residential purposes.

Conversions of former single dwelling properties into flats

When turning the single dwelling into several flats or units, the sound performance requirements of Building Regulations must be met.

Designed in a way that does not adhere to Robust Details

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. Once the design does not strictly abide by the design from Robust Detail approved list, the structure will have to undergo a sound test to ensure it conforms to Building Regulations. The minimum criterion is based on various factors such as the purpose of the development and if it is a permanent dwelling or rooms to be used as residences like students’ accommodations and hotels.

Towns in the UK AF Acoustics Services can be Found

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Spring-Park. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. You can find our consultants all over the south east region of the country. That way we give you the most affordable quotation that will meet your budget needs.

Why you should pick AF Acoustics for your sound testing

We have helped many homes and business owners in Spring-Park with their sound tests and building’s sound performance. Our customers endorse and recommend us because of the following advantages of working with us.

Over 15 years’ experience

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. Our clients in the UK are completely satisfied with our acoustic solutions. Irrespective of the type of project you have, minor or major, you can be assured that we’ll give outstanding value for your money.

Competitive prices

We want to ensure that you get the best value for your money. That is why we have one of the most unbeatable rates in and outside Spring-Park. Call us or email today to get a free quotation.

Prompt and productive consultancy

We will listen to your wishes, provide you sturdy solutions and deliver acoustic consultancy through our expertise. We will give you the right answers and expert guidance so that you can get effectual solutions to your problems.

Adjustable test dates

Because your convenience is important to us, we provide several options to help you choose a test date that is best for you. If you want to schedule sound insulation testing in Spring-Park, phone or email us immediately.

Get your test reports quickly

The sooner you get a report on the completed sound insulation test, the sooner you can take appropriate action. We strive to deliver next day reporting in all scenarios regardless of the complexity or size of the project. That way, you can take immediate action on the recommendations given. Our reports are thorough and cover all the important issues.

Sound Insulation Testing Services We offer

With AF Acoustics, you get a highly effective and expert acoustic advice which our customers all over UK have benefited from. Contact us now for more information on how we can assist you with your acoustics requirements.

Airborne and impact ceilings/floor tests

These are taken on separating floors/ceilings between residences. The measurement of the extent of noise transmitted directly through impact from one adjoining room to another is known as impact testing. Airborne and impact tests are conducted on the floor partitions between liveable rooms.

PART E Testing

Our sound tests align to Part E of Building Regulations guideline, which thoroughly describes sound resistance level and performance from structures. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound test

We want to give our customers the most highest chance to acquire a pass and via our offer skilled services. To make sure a new residence meets with the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw, an airborne wall test and an airborne and impact floor test will need to be conducted. We regularly provide consultations for project managers and developers from the very start of developments, ensuring peace of mind when it comes time to having a sound test. Contact us today for more information about our sound testing services or to book a no obligation quote, free of charge.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Acoustic design tests in schools in accordance with BB93

Building Bulletin 93 (BB93) explains the sound performance requirement for the acoustics of school buildings. It likewise states how a school can meet this requirement. If building a new school in Spring-Park, we can test the school to check if it meets the requirements of BB93.

Acoustic plan

AF Acoustics give definite design services and consultancy services to all types of developments. We create bespoke solution and can provide information on the best available acoustic products. We will tailor our design solutions to your project.

When constructing a building, it’s vital you get advice from the right acoustic consultant on time. AF Acoustics uses professional expertise to discover your acoustic needs early on and proffer ideas on how to meet them.

We are able to assist with:

Acoustic detail design for architects involved in residential developments for compliance with Part E Regs, BS8233, and so on. Detail layout for the commercial, health and educational constructions in order to align with regulations. Specification and design of building services for noise control in residential and other noise sensitive scenarios Improving sound and public address system in halls, conference rooms etc.

Contact AF Acoustics specialist for sound insulation test quotes

As an independent acoustics consultancy, AF Acoustics is able to provide extensive acoustic survey and design, investigations in the field of planning and noise, architectural and building acoustics, and air permeability testing. We will give you sound advice and guidance no matter who you are or the kind of project you have. To get an accurate quotation, either call us or email info@af-acoustics.com

020 3372 4430 Contact us

Provide us with the following data

In your email or during your phone call, tell us about the following

Construction’s location

Where is your property located in Spring-Park?

How many dwellings are there?

Total number of dwellings in the structure

Number of Storeys

Let us know the number of floors in your development so that we can give you an accurate quotation.

Dwellings arrangements per level

To help us get you an accurate quotation and evaluate the scope of the test to be taken, tell us how many dwellings there are per floor.

Types of construction

What is your building type? This will help us know the kind of test it will undergo.

New property or reconstructed dwelling

The testing requirement for new builds and conversion projects are different. We will need this information to determine what standard the testing ought to follow. With this information, we can easily provide you with an accurate and competitive quote on your project in little time.

Sound testing regulations

Get more credits for Code for Sustainable Homes and EcoHomes environmental assessment project by taking a sound insulation test which are aligned with approved document E building regulations rules.

Building regulations document E resistance to the passage of sound (England and Wales)

We have fully accredited engineers who can visit your property to issue appropriate certification that complies with the building control.

Scotland Standard division for properties

According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Fully detached roofs or walkways that are not used for residential purposes do not have to take the sound tests of the Scottish Standards 5.1.

How to get a pass certificate for your sound test

The best method to guarantee you pass your sound test is to design the building with a view to good sound insulation performance. This shouldn’t be exorbitant, and can save time and cost at the end, without your having to correct sound problem or pay for a re-test. If you’re not certain of how to construct your party walls and floors, to meet Document E 2003 targets, simply contact us for an efficient design service. Whether you want some initial tests on your project, or comprehensive reports at the end, we can help you at the level that you need. The are required in order to have good conditions to undertake the sound insulation tests: Inner and outer doors and windows have been installed and can be used Fit and seal skirting boards Light fittings and switches and plug sockets are fitted and working. Our accomplished acoustic consultants work with developers, planners, contractors, and architects of all sizes from the early stages of the building plan to help limit any potential sound insulation performance problems to the completion of the construction, guaranteeing that all properties meet the criteria of Building Regulations Document E 2003.

Analysis and Report Certificates

To get details of the results of a completed sound insulation test, we will provide you with an analysis and report certificate. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What the results look like

Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. If a partition wall or floor does not comply with Part E standards, repair work and another sound test will be needed. We can give robust advice on that to ensure you pass.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed