Sound insulation testing is used to measure the resistance of sound provided by an element of a building (such as a floor or wall) between dwellings. It essentially measures the effectiveness of the sound proofing treatment installed as part of a build or property development. New structures and reconstructed developments have been mandated by the Building Regulations to test for sound upon completion, since Approved Document E (ADE) was reappraised in 2003.

As many contractors and developers have found to their detriment, without a sound insulation certificate, the Building Control Officer will not issue a completion certificate. We understand how important it is for you to get a sound insulation certificate. That’s why we go the extra mile to make sure you get your certificate as quickly as possible. We take great pride in providing our certificates to you as soon as possible after the tests.

Our fully trained sound insulation test engineers can be on site when you need them. Your AF Acoustics engineer will give you immediate verbal results from the sound test, and you can will have a written report by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Does

Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

What is involved in Sound testing?

While producing lots of noise, sound test needs a quiet site to be conducted efficiently. Due to this fact, the workers in the site should not be present at the time of the test. The process of a sound test is determined by the size and complexity of the site being tested. Generally, a sound insulation test takes about 90 minutes for a simple, regular sized project.

The sound testing engineers then proceed to give verbal results on the site and offer helpful advice on any problem areas noticed during the duration of the test.

You will get a detailed written report and sound test certificate about a day after, if possible. The way a sound test is conducted is determined by ADE of Building Regulations. It mandates that in all developments, every 10 units in a group or sub-group will undertake one set of tests. It explicitly states what a sub-group is in Section 1. There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. The volume of testing carried out on each group is written below.

Why is Sound Insulation Testing Required? Why is it Important?

Before completing a building, all new constructions should be tested for sound insulation, as stipulated by Approved Document E since 2003. Results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. This is to be certain that all new developments meet a uniform minimum criterion for resistance to sound from other parts of the development and adjoining developments. Sound insulation testing is important because sound affects the way we live, whether at work, in the home or whilst at leisure. Noise reduction between walls and floors could result in a more comfortable, productive environment.

Sound insulation and speech privacy are important because not having them results in an unfavourable environment for those living in the development. Let’s take a look at this scenario. An individual living in a block of flats might spend the weekend with friends relaxing and playing loud music. If the sound insulation on adjoining walls and floor is insufficient, the music will be distressful to neighbours, especially if they work at night. Sound insulation impacts people’s lives in various ways. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

Do You Need a Sound Test?

If you’re doing one of the following, then you need a sound test:

  • Constructing a building that has two or more units
  • Constructing a nursing home or rooms that will be lived in, e.g. hotel room or hostel
  • Converting a single development to flats
  • Using designs where Robust Details are not included

Sound insulation is covered and made mandatory under Approved Document E of The Building Regulations.

Either you follow the pre-completion sound testing process stipulated therein or you use Robust Details. This way, you have conformed to the requirements. Robust Details are a set of specific design details for walls and floors that have been previously tested to show compliance and must be used if this route is selected. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. This becomes difficult when you need to pick a more appropriate or cost-effective design that will suit your needs. Sound tests enable you do that, making it more flexible. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.

How Much Will I Pay for a Sound Insulation Test?

To get a free quote for your dwelling, contact us. Not only are we highly experienced in providing sound testing services in UK, our reports and certificates get to the client within one of the fastest turnaround time and our prices are competitive. Send us a price you got that’s better than our and we will try to beat it.

When can I carry out the sound insulation tests?

Ideally, we would conduct a test when a development nears completion, and once all internal and external doors and windows have been fitted. We can test earlier to check if there are any problems. For your sound tests to be conducted successfully we need the property to be quiet, with workers not near the rooms to be tested during the test time (a noisy environment makes the test difficult and sometimes unsuccessful). We also need access to all units unless the test program has been compiled earlier. Finally, we need 240V power supply.

The Procedures of a Sound Insulation Test

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

A pink or white noise generator and a large speaker is used for the test in the biggest room between the two undergoing testing. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. When conducting airborne sound insulation tests, two speakers are placed in each source room. The noise level in the receiving room is measured to get the sound difference between the source and receiving room.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. The room under it is then measured for the noise levels. This is used in calculating and computing the results. These results are checked against Building Regulations ADE conditions for that kind of dwelling. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Equipment do we use?

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. Airborne sound test is the measurement of sound moving through the air through a wall or floor. We use pink or white noise generator and speakers on one side of the partition. A sound level meter is used on calculating sound in both units. For impact sound testing, the equipment used is a tapping machine that uses dropping hammers to create noise and a sound level meter. Testing is done on rooms that can be lived in. E.g. lounges, kitchens, bedrooms and living rooms. You will get the test results in a report within a working day. This report can be used to help sign off your building as it is accepted by Building Control.

A sound test is mandatory for these buildings:

Sound Insulation Testing checks for both airborne and impact noise travelling through new or existing buildings. This may affect party walls and floors between new and existing buildings, or between spaces within a new development.

A new building with not less than two rooms

This ensures that a sound insulation system installed in residences meets the requirements of ADE.

Conversions of former single dwelling properties into flats

The development that has been converted must conform to Building Regulations sound requirements.

Designed in a way that does not adhere to Robust Details

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the design does not completely follow Robust Details, sound insulation testing will occur to be certain the building meets ADE criteria. Minimum criterion differs based on the type and purpose of the development. A development with rooms intended as residences, like a hostel or hotel, won’t have the same criteria as a structure for permanent dwelling.

Where doses AF Acoustics conduct tests in UK?

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Surrey-Quays. Af Acoustics work with individuals, government agencies, planning and environmental consultancies, and architects. Our consultants can be found in various places in the south east region. This way you get an affordable price.

Why AF Acoustics is the right choice for your sound insulation test

We have helped many homes and business owners in Surrey-Quays with their sound tests and building’s sound performance. Our customers endorse and recommend us because of the following advantages of working with us.

Over 15 years’ experience

We understand the industries our clients are in. Therefore, we provide advice that is technically adequate, useful and applicable. Our clients in the UK are completely satisfied with our acoustic solutions. Irrespective of the type of project you have, minor or major, you can be assured that we’ll give outstanding value for your money.

Competitive prices

We want to ensure that you get the best value for your money. That is why we have one of the most unbeatable rates in and outside Surrey-Quays. Call us or email today to get a free quotation.

Ultrafast and efficient consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. When you reach out to us for professional advice, we make certain that we render accurate solutions rapidly. We suggest productive answers that handle your present and long-term desires to the maximum.

Adjustable test dates

Your convenience is also important to us. This is why we offer you flexible options that let you pick test dates that are most convenient for you. Take the first step towards your sound insulation testing in Surrey-Quays by calling us now.

Test reports arrive the next day

The sooner you get a report on the completed sound insulation test, the sooner you can take appropriate action. We strive to deliver next day reporting in all scenarios regardless of the complexity or size of the project. The report will be detailed and thorough so that all necessities are written out and any advice provided.

Sound Insulation Testing Services We offer

With AF Acoustics, you get a highly effective and expert acoustic advice which our customers all over UK have benefited from. Call or mail us today so we can provide you with more knowledge on your acoustics needs.

Impact and airborne floor test

These are only carried out on separating floor/ceiling between dwellings. Impact testing evaluates how much the sound flowing from one partition to another through party floors via impact is. Airborne and impact tests are conducted on the floor partitions between liveable rooms.

Approved Document E test

Our sound insulation tests meet the requirements of Building Regulations Part E, which describes building structures resistance to the movement of sound within and from adjoining structures. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound insulation test

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. In newly completed constructions, an airborne wall test and an airborne and impact floor test will be needed to meets the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We frequently give robust advice to project managers and developers from the start of the construction, ensuring that they’ll have adequate sound insulation to pass a sound test. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 acoustic design tests in schools

Building Bulletin 93 (BB93) describes the minimum requirement for the acoustics of a school building. It also stipulates how a school can conform to Building Regulations. If you’re constructing a new school in Surrey-Quays, we can conduct a test to be certain it meets the standards of BB93.

Acoustic plan details

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

As anyone who has had to deal with the acoustic properties of a building will know, it’s important to get the correct advice, as early as possible from a good acoustic consultant. AF Acoustics can help you to identify the correct acoustic requirements for your project at an early stage and advise on the best means to meet them using expert knowledge of acoustic design.

We can help with:

Acoustic detail plan for architects associated with advancements on residences adhering to ADE, BS8233, etc. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Specifications and building services design for control of noise in noise sensitive areas. Increasing sound through public enterprise and sound reinforcement systems in conference rooms, halls, lecture theatres and the like.

Get a sound insulation testing quotation by contacting our experts

As an independent acoustics consultancy, AF Acoustics is able to provide extensive acoustic survey and design, investigations in the field of planning and noise, architectural and building acoustics, and air permeability testing. We want to give you expert guidance and provide working solutions, whether you are an individual or an organisation. For a quotation, call or email info@af-acoustics.com

020 3372 4430 Contact us

We will need the following information:

In your email or during your phone call, tell us about the following

Construction’s location

Where in Surrey-Quays the property is situated

How many dwellings are there?

What is the number of units in the development?

Total number of floors

To get a precise quote, let us know the total number of floors you have.

Number of dwellings per floor

How many units are on each floor? Knowing this will help us give you an appropriate quotation.

Type of development

Let us know the type of development you have so that we can undertake the required tests for it.

New dwelling or converted property

Knowing if your building is new or converted allows us to give you a competitive quotation and prepare the right test for it.

Building regulations for sound test

Our ADE compliant sound tests can help you gain credits for Code for Sustainable Homes and EcoHomes environmental assessment structures.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

Our certified engineers can come to your building whenever it might suit you to undertake sound insulation testing to Part E of Building Regulations adherence, recognised by Building Control.

Standard division for structures (Scotland)

Section 5.1 of the Scottish Building Standards explicitly describes expected energy performance of dwellings. It states, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” The following are exempt from the testing techniques given in annex 5.C. of the Scottish Standard and Standard 5.1 – completely segregated rooftops, houses or walkways whose access is only used for upkeep or for the utilization of the inhabitants of the dwelling beneath.

How to make sure you pass your sound test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. Are you uncertain that the separating floor and walls you will build will adhere to Document E 2003 conditions? You can book our design services. Our consultation may include several site visits and thorough design reports, or more basic initial tests on your structure. The are required in order to have good conditions to undertake the sound insulation tests: Windows and internal and external doors are fitted and operable Skirting boards are fitted and sealed Light switches, plug sockets, and light fittings are adequately fixed. Our expert acoustic consultants work with planners, developers, architects and contractors from the beginning of the design stage till when the property is finished to ensure it meets the conditions of Document E 2003.

Analysis and Report Certificates

After the test, AF Acoustics’ competent and well trained engineers can let you know the verbal results of your sound test and provide feedback on issues noticed during the test. We endeavour to send an investigation and report certificate the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The way the results look

Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. If a partition wall or floor does not comply with Part E standards, repair work and another sound test will be needed. We can give robust advice on that to ensure you pass.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed