Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

As many contractors and developers have found to their detriment, without a sound insulation certificate, the Building Control Officer will not issue a completion certificate. As a result of this, we try to ensure that you are issued with a sound insulation certificate as fast as possible. In fact, we are proud of our turnaround times and our team will issue your certificates as quickly as we possibly can.

Even before you get the certificate, you will receive the results of the test. First, our skilled and competent sound insulation test will engineers give you a verbal result at the site. Then, a written report is sent to you within 24 hours of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Does

Walls and floors that separate dwellings in a building are expected to be sound tested, as mandated by Document E of Building Regulations. Only dwellings that have used Robust Details, which licensed before the installation, are exempted from the test. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

What is involved in Sound Insulation Testing

While producing lots of noise, sound test needs a quiet site to be conducted efficiently. Due to this fact, the workers in the site should not be present at the time of the test. Undertaking sound tests on site varies according to the size and complexity of the building project and the site conditions. Most of the time the test will be conducted in 90 minutes, for a simple, regular sized construction.

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern.

The entire report and individual sound test certificate will be sent to you the day after. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). ADE also states the categories of developments that should be tested. There are three: rooms, flats and houses (including bungalows) that are lived in. Examples are student accommodation, hotel rooms and care homes. Find below the testing stipulation for each kind of development.

Importance of Sound Insulation Testing

After the 2003, Approved Document E mandates that all new structures in UK must take a sound insulation test before completion. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. This is to be certain that all new developments meet a uniform minimum criterion for resistance to sound from other parts of the development and adjoining developments. Testing for sound insulation is vital because sound influences how we live in the office, while relaxing or in the house. Restricting the sound that moves between floors and walls could result in a more relaxed and better surrounding.

Sound insulation and speech privacy are critical for a variety of reasons. Inadequate sound insulation can be extremely distressing to those affected by it. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. This is just one instance of the influence of sound insulation on our lives. Then there are developments where each neighbouring room / flat / unit has mixed uses. If the development has passed the sound insulation test, noise is reduced to a minimum.

Do I Need a Sound Insulation Test?

Your development needs a sound insulation test if it meets one of the following criteria:

  • It’s design does not have Robust Details
  • It’s a new building with 2 or more dwellings
  • It’s being constructed to be used as a residence, like a hotel room or a hostel, or as a nursing home
  • It was once a single dwelling but is being turned into a development with several flats or units.

Document E of the Building Regulations explains sound insulation testing and makes it a necessity.

Either you follow the pre-completion sound testing process stipulated therein or you use Robust Details. This way, you have conformed to the requirements. Robust Details are design details for walls that were tested formerly and meet the sound performance parameters stated by Part E of Building Regulations. Using Robust Details, without taking a test, limits you to the design you’ve picked. With sound testing, however, you’re free to pick from any design, including more cost effective and appropriate ones. This makes it a more efficient process than Robust Details. It also gives architects the opportunity to evaluate their design and give your structure a much better sound insulation which will increase sound performance.

Price for Sound Insulation Testing

To get a free quote for your dwelling, contact us. We have worked throughout the country on all sizes of project, and should a sound insulation report and certificates be required, we can provide the fastest turnaround times and most competitive prices available. If you get a better quote elsewhere, simply forward it to us and we will try and beat it!

Ideal Period for a Sound Insulation Test

The ideal period for a sound insulation test is after the fitting of windows and doors, and before the building is finished. If you want, AF Acoustics can conduct tests before then to find out if there are any problems on your property. These are the things we need to conduct the test:

  • 240V power supply
  • A quiet environment
  • Access to all the units of the structure unless places to test have been decided before then.

The Procedures of a Sound Insulation Test

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. The boundary floors and walls get airborne tests. Floors get an additional impact test.

The test uses a dodecahedron speaker and pink or white noise generator for source sound. The sound source is placed in the largest room of the two. A sound level meter is then used to take noise measurements within the source room and the receiver room. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. Airborne sound tests are conducted in this manner: two singular speaker positions are used for every source room. The noise in the receiver room is measured to determine the variations in noise level between the source and receiver room.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact tests are done by placing a standardised tapping machine on the floor. The sound pressure level at the receiving room, which is below the source room, is measured. Calculations based on these measurements are undertaken and the results compared to the Building Regulations Part E requirements for the given type of the building. Without the mathematical formulae used in the calculations, this is a simple explanation, however, it helps explain the testing process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

Our high-tech sound insulation machines are UKAS calibrated and our accredited expert engineers conduct the test using Building Regulations present criteria. The calculation of the level of noise transmitted through the air between two adjoining units is known as an airborne sound insulation test. We use pink or white noise generator and speakers on one side of the partition. A sound level meter is used on calculating sound in both units. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. You will get the test results in a report within a working day. This report can be used to help sign off your building as it is accepted by Building Control.

These kinds of properties should undergo a sound insulation test:

For sound testing we usually undertake impact and airborne sound test on buildings. This affects the separating floors and walls between habitable rooms of buildings and developments.

A new building with not less than two rooms

This is to ensure that the sound proofing of the building is up to standard for residential purposes.

A single dwelling that was turned into a development with several flats or units

The transformation of a single dwelling property into flats must adhere to the sound insulation standards of Building Regulations.

Design not using Robust Details

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. If the building design does not strictly adhere to Robust Details, a sound insulation test becomes necessary to meet Building Regulations. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Areas in the UK AF Acoustics Conduct Test

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Wallend. Our clientele also include government agencies, architects, and organisations involved in planning and environmental consultancy. Our consultants can be found in various places in the south east region. This way you get an affordable price.

Why choose AF Acoustics for Sound Insulation Testing?

We have helped many homes and business owners in Wallend with their sound tests and building’s sound performance. Our customers endorse and recommend us because of the following advantages of working with us.

More than 15 years’ experience

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. By doing this, we have been able to continuously satisfy clients in the UK and meet their acoustic needs for over 15 years, providing great value for money.

Great prices

To make certain that all clients in Wallend can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Wallend. Contact us right now to get a quotation that’s completely free of charge.

Prompt and productive consultancy

We will interpret your problems and necessities, present you with vigorous ideas and provide acoustic advice through our extensive experience. Both your short and long-term needs are handled with our professional guidance and quick answers to your problems.

Adjustable test dates

Our test date options let you pick what will suit your schedule because your comfort is essential to us. Contact us today to get sound testing in Wallend

Next day reporting

We try to provide test reports within 24 working hours. That way, you can take the right action based on the results of the test. The delivered report will be comprehensive and well detailed to ensure all relevant issues are covered and any recommendations are provided.

AF Acoustics sound testing services

We offer a wide range of thorough acoustic solutions for our clients nationwide, and we ensure a high calibre and effective approach. Telephone or email us today for more data on how we can assist you with your acoustic requirements.

Impact and airborne tests for floors

These are taken on separating floors/ceilings between residences. An impact test examines the level of noise moving from one dwelling to another through impact on adjoining floors/ceilings. Airborne and impact tests are conducted on the floor partitions between liveable rooms.

Approved Document E test

Document E of Building Regulations requires certain criteria for the sound performance of a dwelling. Our sound insulation tests are conducted in accordance to these criteria. The impact sound test of new dwellings should be 62dB L’nTw or less and airborne sound insulation 45dB DnTw+Ctr or more while impact results for reconstructed properties should be 64dB L’nTw and airborne sound insulation 43dB DnTw+Ctr or more.

Sound insulation test

We offer the highest levels of service and expertise and are always happy to work with you to give you the best possible chance of achieving a pass certificate. In new properties, an airborne and impact test will help you guarantee the building meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly provide consultations for project managers and developers from the very start of developments, ensuring peace of mind when it comes time to having a sound test. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) describes the minimum requirement for the acoustics of a school building. It also stipulates how a school can conform to Building Regulations. If you’re constructing a new school in Wallend, we can conduct a test to be certain it meets the standards of BB93.

Acoustic design details

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

As anybody who has needed to handle the acoustics for a building will know, it’s essential to get proper advice, early in the project from a good acoustic expert. AF Acoustics can help you with identifying the right acoustic needs and standard for your construction at the beginning period and advise you on how to meet them.

We are able to assist with:

Acoustic detail design for architects engaged with residential improvements in consistence with Part E Building Regulations, BS8233 and so on. Detail plans for the educational, commercial and healthcare industry so as to meet with the current criteria. Specification and design of building services for noise control in residential and other noise sensitive scenarios Public address and sound reinforcement for conference room, lecture theatres and so on.

Get a sound insulation testing quotation by contacting our experts

AF Acoustics is a leading acoustic consultancy. It provides the following services: architectural and building acoustics, acoustics design, survey and investigation in the field of planning and noise, and examining and controlling air vibrations while conducting air leakage tests. We will give you sound advice and guidance no matter who you are or the kind of project you have. To get an accurate quotation, either call us or email info@af-acoustics.com

020 3372 4430 Contact us

We will need the following information:

When calling or emailing us please provide the following data

Place where the building is being built

Where in Wallend is your construction?

Number of dwellings

Total number of dwellings in the structure

Number of levels in the structure

For an accurate calculation of the quote, tell us the number of storeys

Dwellings configuration per floor

This will also be needed to determine scope of the testing and provide an accurate quote

Types of construction

Let us know the type of development you have so that we can undertake the required tests for it.

New property or reconstructed dwelling

Newly completed constructions and refurbished structures have different requirements for sound insulation testing. This is why it’s important to provide this information beforehand. Our quotation is available at any time.

Sound testing regulations

Our sound insulation tests are conducted in accordance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building requirements. You can also get credits for Code for Sustainable Homes and EcoHomes environmental assessment projects.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

We have fully accredited engineers who can visit your property to issue appropriate certification that complies with the building control.

Standard division for developments (Scotland)

Section 5.1 of the Scottish Building Standards states “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” The following are exempt from the testing techniques given in annex 5.C. of the Scottish Standard and Standard 5.1 – completely segregated rooftops, houses or walkways whose access is only used for upkeep or for the utilization of the inhabitants of the dwelling beneath.

How to get a pass certificate for your sound test

Make sure you pass your sound test by having efficient sound insulation included in the building design. It saves time and money and helps you avoid repair work and re-test expenses. We offer design services that help you construct separating walls and floors with good sound performance that meet ADE demands. We can study design reports, complete site visits and sound test the development to provide you with the level of assessment and consultation that your project requires from start to finish. The following will give you a better chance of passing the sound test: All windows and doors have been fitted and work Skirting boards are fixed Plug sockets, light switches and fittings are in place and working. We work with several professionals in construction from the beginning of the design stage to the completion of the development to make certain it conforms to Document E 2003 of Building Regulations.

Certificates for test evaluation and report

To get details of the results of a completed sound insulation test, we will provide you with an analysis and report certificate. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

How the results are

You will get your sound insulation test certificate whether you pass or fail the sound tests. In the event that some part of the building does not meet up with the conditions of Document E, remedial work and a retest is required. We give remedial design advice to help you achieve Building Regulations standards.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed