Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. Part E of Building Regulations requires sound insulation in buildings and mandates that all newly completed constructions and rehabilitated developments go through sound testing.

At the completion of the test, a sound insulation certificate is issued. Without the certificate, Building Control will not release the building completion certificate to the contractors and developers of the project. As a result of this, we try to ensure that you are issued with a sound insulation certificate as fast as possible. In fact, we pride ourselves on issuing our sound insulation testing certificates as quickly as possible.

Our highly capable sound test engineers will be available on site when you need them. They will give you a verbal result of the test, once taken and a written report will be issued to you by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Insulation Test?

In order to comply with Part E of the Building Regulations, developments will require the testing of separating walls and floors. The only exception is where Robust Details have been used. Sound Insulation Testing tests for both the airborne sound and the impact sound which travels through new or existing buildings . The tests cover party walls and floors between new and existing buildings, or between spaces within a new development entirely.

What is involved in Sound testing?

A sound insulation test creates a high amount of noise but needs a site with low noise levels to be taken effectively. As a result of this, workers in a testing area might have to leave the development temporarily, so that the test can be free from errors. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. A structure that is simple and the conventional size will usually take 90 minutes to be tested.

Once this is done, the sound test engineers give temporary results while they’re still on the site. They will also provide suggested solutions to possible problem areas noted during testing.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. Every 10 units in a group or sub-group are to be tested, according to ADE. A sub-group is stipulated in Section 1. Of ADE ADE goes on to define and group the type of structures that will undergo testing. They are houses, flats and rooms that are being used or are planned to be used as residences; such as student accommodation, care homes and hotel rooms. How much testing that is required for each category can be found below.

Importance of Sound Insulation Testing

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. This is to be certain that all new developments meet a uniform minimum criterion for resistance to sound from other parts of the development and adjoining developments. Sound insulation testing is important because sound affects the way we live, whether at work, in the home or whilst at leisure. Noise reduction between walls and floors could result in a more comfortable, productive environment.

Sound insulation and having privacy while speaking are crucial for a number of reasons. When sound insulation is deficient, it can cause discomfort to occupants. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. This is one way sound insulation can affect how a person lives. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

Do You Need a Sound Test?

If you’re doing one of the following, then you need a sound test:

  • Constructing a building that has two or more units
  • Constructing a nursing home or rooms that will be lived in, e.g. hotel room or hostel
  • Converting a single development to flats
  • Using designs where Robust Details are not included

Document E of the Building Regulations explains sound insulation testing and makes it a necessity.

To conform, you can either follow the procedure outlined in ADE or make use of Robust Details. Robust Details are design details for walls that were tested formerly and meet the sound performance parameters stated by Part E of Building Regulations. Using Robust Details, without taking a test, limits you to the design you’ve picked. Sound testing provides more flexibility by allowing different designs and is often therefore more cost effective in many ways compared to the Robust Details Scheme. It also gives architects the opportunity to evaluate their design and give your structure a much better sound insulation which will increase sound performance.

How much does sound insulation testing cost?

Simply contact us and we will be able to provide a free, no obligation quotation as to the requirements and costs for your development. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

Ideal Period for a Sound Insulation Test

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

How a Sound Test is Done

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. Airborne tests are conducted on party walls while impact and airborne tests are conducted on party floors.

A big or multidirectional speaker, with a generator of pink or white noise is used to the biggest room. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. The meter is also used to measure the background sound, to ensure that it’s 10dB lower than the source sound, as is the standard. More background sound leads to creating a higher source sound. For airborne sound tests, two individual speaker positions are used for each source room. Measurements are then made to determine the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

Finally, the difference in noise level is modified to accommodate reverberation time and background noise that was already in the receiver room. Reverberation time is how long it takes sound to decay by 60dB. Impact tests are carried out by means of a tapping machine placed on the floor to be measured. The sound level in the room below it is recorded. This is used in calculating and computing the results. These results are checked against Building Regulations ADE conditions for that kind of dwelling. Of course, this is a simple way of describing the procedure followed when a sound test is carried out, but it enables you to understand it better.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. The calculation of the level of noise transmitted through the air between two adjoining units is known as an airborne sound insulation test. The equipment we use are a sound level meter, loudspeaker and white or pink noise generator. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. The tests are carried out in rooms suitable for residential use like bedrooms, lounges and kitchens. You will get the test results in a report within a working day. This report can be used to help sign off your building as it is accepted by Building Control.

It’s important to undertake a sound test if you have this kind of building:

For sound testing we usually undertake impact and airborne sound test on buildings. This affects the separating floors and walls between habitable rooms of buildings and developments.

A new building with 2 or more dwellings

With the sound test, you can be certain that the property has a good acoustic performance.

A single dwelling that was turned into a development with several flats or units

The transformation of a single dwelling property into flats must adhere to the sound insulation standards of Building Regulations.

Using designs where Robust Details are not included

The Robust Detail Scheme, set up in 2004 by Robust Details Ltd, architects create design details for walls and floors that were tested formerly for sound insulation and meet the sound performance parameters stated by Part E of Building Regulations. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. The minimum requirements during testing will depend on a variety of factors such as if the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

Parts of the UK AF Acoustics Cover

AF Acoustics is an acoustic consultancy providing acoustic design services to clients nationwide, especially in Wembley. Our clients include architects, planning and environmental consultancies. We also work with government agencies and private individuals. You can find our consultants all over the south east region of the country. That way we give you the most affordable quotation that will meet your budget needs.

Why you should choose AF Acoustics

Having rendered high quality service to numerous customers in Wembley, we have gotten great positive feedback and recommendation from our clientele due to the following:

Over 15 years’ experience

We are able to offer helpful functional solutions that will solve our customer’s needs. By doing this, we have been able to continuously satisfy clients in the UK and meet their acoustic needs for over 15 years, providing great value for money.

Competitive prices

To make certain that all clients in Wembley can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Wembley. Contact us right now to get a quotation that’s completely free of charge.

Effective and quick consultancy

We offer strong durable advice based on your problem and give highly knowledgeable acoustic advice. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Flexible test dates

Our test date options let you pick what will suit your schedule because your comfort is essential to us. Call us to get your sound testing in Wembley undertaken.

Next day reporting

We try to provide test reports within 24 working hours. That way, you can take the right action based on the results of the test. That way, you can take immediate action on the recommendations given. Our reports are thorough and cover all the important issues.

Sound insulation testing services AF Acoustics undertake

AF Acoustics offer a range of comprehensive acoustic solutions to customers nationwide, and we guarantee a high-quality and high-efficiency approach. To find out more about we can help you with your acoustics needs, call or email us right away.

Impact and airborne tests for floors

These are performed on floors and/or ceilings between units. An impact test examines the level of noise moving from one dwelling to another through impact on adjoining floors/ceilings. The adjoining floors/ceilings of rooms intended as residences usually have both impact and airborne sound tests.

PART E Testing

Our sound insulation tests meet the requirements of Building Regulations Part E, which describes building structures resistance to the movement of sound within and from adjoining structures. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound Insulation Testing

We offer the highest levels of service and expertise and are always happy to work with you to give you the best possible chance of achieving a pass certificate. A new dwelling may have to undergo an airborne and impact test to meet the benchmark of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) explains the sound performance requirement for the acoustics of school buildings. It likewise states how a school can meet this requirement. Are you building a new school in Wembley? Contact us to arrange a sound test and make sure it meets the benchmarks of BB93.

Acoustic layout

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

When constructing a building, it’s vital you get advice from the right acoustic consultant on time. AF Acoustics uses professional expertise to discover your acoustic needs early on and proffer ideas on how to meet them.

We can help with:

Acoustic detail design for architects engaged with residential improvements in consistence with Part E Building Regulations, BS8233 and so on. Detail designs for the health, educational and commercial projects in order to meet up with the necessary requirements. Specifications and building services design for control of noise in noise sensitive areas. Public address and sound reinforcement (conference rooms / lecture theatres etc.)

Get a sound insulation testing quotation by contacting our experts

AF Acoustics is a leading acoustic consultancy. It provides the following services: architectural and building acoustics, acoustics design, survey and investigation in the field of planning and noise, and examining and controlling air vibrations while conducting air leakage tests. We want to give you expert guidance and provide working solutions, whether you are an individual or an organisation. For a quotation, call or email info@af-acoustics.com

020 3372 4430 Contact us

We will need the following information:

In your email or during your phone call, tell us about the following

Location of development

Where is your property located in Wembley?

Number of dwellings

What is the number of units in the development?

Total number of floors

For an accurate calculation of the quote, tell us the number of storeys

Configuration of dwellings (no. of units per level)

This will also be needed to determine scope of the testing and provide an accurate quote

Building type

What is your building type? This will help us know the kind of test it will undergo.

New Build or conversion project

The testing requirement for new builds and conversion projects are different. We will need this information to determine what standard the testing ought to follow. With this information, we can easily provide you with an accurate and competitive quote on your project in little time.

Sound Insulation Testing Regulations

We provide sound testing and sound insulation testing on all types of buildings, for compliance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building Standards. Testing can also gain credits for Code for Sustainable Homes and EcoHomes environmental assessment schemes.

Part E of building regulations resistance to the passage of sound (England and Wales)

We can send our authorised engineers to your development whenever the timing is ideal to undertake sound insulation testing that conforms to Building Regulations Document E consistence, as accepted by Building Control.

Standard division for structures (Scotland)

Section 5.1 of the Scottish Building Standards stipulates that “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be taken at the completion of the building, using procedures given in annex 5.C. of the Scottish Standards. These standards don’t apply to detached structures that have access only for maintenance or are to used only by the occupants who live below.

How to make sure you pass your sound test

The most effective way to ensure you pass your sound test is to plan the project with sound insulation in mind. This does not need to be costly, and can save considerable time and expense at the end of the project, not to mention avoiding escalating remedial and re-test costs. If you’re not certain of how to construct your party walls and floors, to meet Document E 2003 targets, simply contact us for an efficient design service. We can study design reports, complete site visits and sound test the development to provide you with the level of assessment and consultation that your project requires from start to finish. The are required in order to have good conditions to undertake the sound insulation tests: All windows and door have been fixed and are functioning Skirting boards are fitted Fix all light switches, light fittings and plug sockets. Our accomplished acoustic consultants work with developers, planners, contractors, and architects of all sizes from the early stages of the building plan to help limit any potential sound insulation performance problems to the completion of the construction, guaranteeing that all properties meet the criteria of Building Regulations Document E 2003.

Certificates for test evaluation and report

To obtain a thorough evaluation of your building, we issue a report certificate within 24 working hours where possible. Our highly capable sound test engineers will give you a verbal result of the test, once the test is taken and proffer solutions to possible problems or future areas of concern. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What do the results look like?

A sound insulation certificate will be sent to you whether the property has a good sound performance in accordance with ADE or not. In the event that some part of the building does not meet up with the conditions of Document E, remedial work and a retest is required. We give remedial design advice to help you achieve Building Regulations standards.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed