Sound insulation testing involves the use of specialist equipment to examine how much sound is reduced off by floors and walls, of a building. It checks if a dwelling’s sound proofing treatment meets the requirements set out in Approved Document E. The Building Regulations Approved Document E (ADE) states all new dwellings and renovated constructions should undergo sound testing.

At the completion of the test, a sound insulation certificate is issued. Without the certificate, Building Control will not release the building completion certificate to the contractors and developers of the project. We know how important a sound insulation certificate is to you. That is why we work hard to make certain that you get the certificate quickly. In fact, we pride ourselves on issuing our sound insulation testing certificates as quickly as possible.

AF Acoustics’ competent and well-trained engineers, who will be available for testing, can even let you know the verbal results of your sound test. You will receive a written report in the space of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

How Sound Testing Works

Walls and floors that separate dwellings in a building are expected to be sound tested, as mandated by Document E of Building Regulations. Only dwellings that have used Robust Details, which licensed before the installation, are exempted from the test. Sound insulation tests examine airborne and impact sound moving between separating walls and floors. The tests include party walls and floors between structures or between spaces within a new development.

The Procedures Involved in a Sound Insulation Test

Even though sound insulation testing equipment produces lots of noise, sound testing requires quiet conditions and dwellings. Because of this, workers on the site would have to leave during the time of the test, to avoid errors in the test calculation. The way a sound test is administered depends on the size and type of building and the development’s condition. A structure that is simple and the conventional size will usually take 90 minutes to be tested.

Once it is completed, the engineers will give a verbal interim result on the site and basic helpful information on what was noticed during the test, e.g. possible sound issues and future places that could cause problems.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). Buildings to be tested are categorised into three kinds: houses, flats and rooms like care homes, student accommodation and hotel rooms. Find below the testing stipulation for each kind of development.

Why Should Your Dwelling Undergo Sound Testing

Before completing a building, all new constructions should be tested for sound insulation, as stipulated by Approved Document E since 2003. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. ADE ensures that new building are resistant to noise from adjoining buildings and other rooms within the same building. Sound affects our life no matter where we are, at home, work or while relaxing. Places with lowered noise are more comfortable and enabling. Sound testing ensures that noise reduction in a building is effective.

Sound insulation and speech privacy are critical for a variety of reasons. Inadequate sound insulation can be extremely distressing to those affected by it. It would mean noise moving from one flat to another in a block of flats. If, for example, an occupant works at night and happens to hear loud music from a neighbour upstairs on a weekend night, it would be very discomforting. Sound insulation helps improve the quality of a person’s life in diverse ways. In a structure with flats for mixed purposes, a sound insulation test will make sure that there is maximum sound resistance from party walls and floors and less noise.

Do You Need a Sound Test?

You need sound insulation testing if you:

  • Build a new development of 2 or more dwellings / flats
  • Convert a former single dwelling into flats
  • Build a Nursing Home or rooms for residential use, i.e. hotel or hostel
  • Have designs which do not adhere to Robust Details

Document E of the Building Regulations explains sound insulation testing and makes it a necessity.

Either you follow the pre-completion sound testing process stipulated therein or you use Robust Details. This way, you have conformed to the requirements. Robust Details are a set of specific design details for walls and floors that have been previously tested to show compliance and must be used if this route is selected. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. Sound insulation testing is a more flexible approach. You can pick from a plethora of designs, as opposed to Robust Details. Sound insulation testing can also help architects enhance their building design and in turn the sound insulation of the building.

Price for Sound Insulation Testing

Simply contact us and we will be able to provide a free, no obligation quotation as to the requirements and costs for your development. Not only are we highly experienced in providing sound testing services in UK, our reports and certificates get to the client within one of the fastest turnaround time and our prices are competitive. Send us a price you got that’s better than our and we will try to beat it.

Sound Insulation Test Time

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. During the test, you should provide the following:

  • Access to all rooms. The only exception is if a schedule was created before the test time.
  • 240V power supply
  • A noiseless site

The Process of a Sound Test

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. The separating walls undergo airborne tests while separating walls and floor undergo airborne and impact tests.

The airborne sound insulation test is carried out with a large speaker or dodecahedron speaker, using a white or pink noise generator to create the source sound, almost always in the largest room of the two rooms under testing. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. For airborne sound tests, two individual speaker positions are used for each source room. Measurements are then made to determine the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

This difference is modified to include background noise in the receiver room and reverberation time – time whereby a sound fades away in a closed space by 60dB. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. The sound level in the room below it is recorded. This is used in calculating and computing the results. These results are checked against Building Regulations ADE conditions for that kind of dwelling. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. An airborne sound test measures levels of sound transmitted through the air through a separating element. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. For impact sound testing, the equipment used is a tapping machine that uses dropping hammers to create noise and a sound level meter. Testing can only be completed on ‘habitable’ rooms. Habitable rooms can be bedrooms, lounges, living rooms and open plan kitchen/ living spaces. Test findings are fed into a report that will be sent to the client. This report will always be acceptable to Building Control and will help you to get your development signed off.

Sound Insulation Testing is necessary for these types of builds:

Sound insulation tests examine airborne and impact sound moving through buildings. It is usually undertaken between party walls and floors between buildings or between spaces within a new development.

A structure with 2 or more units/flats

This makes certain that the dwellings have adequate sound proofing.

A single dwelling that was turned into a development with several flats or units

When the development is completed, ADE of Building Regulations should be checked, and sound insulation tested accordingly.

Using designs where Robust Details are not included

The Robust Details scheme was set up in 2004 by Robust Details Ltd as a way to help architects and builders design and construct separating elements with the confidence that the separating wall and/or floor will be capable of achieving the sound performance parameters in Approved Document E, and comply with the Building Regulations. If the building design is slightly different from Robust Details, a sound test is essential so that Building Regulations criteria can be met. Minimum criterion differs based on the type and purpose of the development. A development with rooms intended as residences, like a hostel or hotel, won’t have the same criteria as a structure for permanent dwelling.

Where doses AF Acoustics conduct tests in UK?

As an acoustics design services firm, AF Acoustics provides acoustic consultancy to various individuals and businesses nationwide, especially in Woodford. Our clients include architects, planning and environmental consultancies. We also work with government agencies and private individuals. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.

Why choose AF Acoustics for Sound Insulation Testing?

Having rendered high quality service to numerous customers in Woodford, we have gotten great positive feedback and recommendation from our clientele due to the following:

More than 15 years’ experience

With more than 15 years of experience, we have a deep knowledge of our customers’ industry and provide actionable strong advice tailored to their needs. Our clients in the UK are completely satisfied with our acoustic solutions. Irrespective of the type of project you have, minor or major, you can be assured that we’ll give outstanding value for your money.

Competitive rates

To ensure all clients in Woodford can afford superior quality sound insulation testing, we offer some of the most competitive rates you can both in and outside Woodford. If in doubt, contact us now for a free no-obligation quote.

Effective and quick consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. We will give you the right answers and expert guidance so that you can get effectual solutions to your problems.

Flexible test dates

Because your convenience is important to us, we provide several options to help you choose a test date that is best for you. Call us now to schedule sound insulation testing in Woodford

Fast turnaround for your report

When you get your sound test report fast, you’re able to take corrective action. We try to issue reports on the next working day no matter how large or complex the project. The conveyed report will be exhaustive, covering every issue point by point to guarantee that the best suggestions are given.

Sound Insulation Testing Services We offer

AF Acoustics provide a scope of exhaustive and detailed acoustic solutions for clients across the country, making certain our techniques have the best quality and performance. Call or mail us today so we can provide you with more knowledge on your acoustics needs.

Airborne and impact tests for floors/ceilings

These are taken on separating floors/ceilings between residences. Impact testing evaluates how much the sound flowing from one partition to another through party floors via impact is. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

PART E Testing

Our sound insulation testing in accordance with Building Regulations Approved Document E, which sets out details pertaining to the resistance to the passage of sound. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound Insulation Testing

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. In newly completed constructions, an airborne wall test and an airborne and impact floor test will be needed to meets the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. When working with AF Acoustics, developers and project managers get acoustic advice right from the start of the building project. That way, they can make sure their developments have a good sound performance. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 testing of acoustic design in schools

For a school to meet up with Building Regulation acoustic requirements, it must adhere to Building Bulletin 93 (BB93) which explains the sound insulation expectation for schools in detail. If you’re constructing a new school in Woodford, we can test the sound performance to evaluate if it meets the standards of BB93.

Acoustic plan

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

Getting advice on the acoustics of a development as early as possible is crucial. AF Acoustics can enable you to do that by advising you on the appropriate acoustic requirements of your property very early in the building process and recommending what to do to fulfil them.

We will help you with:

Acoustic detail design for architects engaged with residential improvements in consistence with Part E Building Regulations, BS8233 and so on. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Specification and design of building services for noise control in residential and other noise sensitive scenarios Public address and sound reinforcement system

Call Our Experts Now For A Sound Insulation Testing Quote

As an independent acoustics consultancy, AF Acoustics is able to provide extensive acoustic survey and design, investigations in the field of planning and noise, architectural and building acoustics, and air permeability testing. Our expert consultation is available to individuals and companies with all types and sizes of constructions. We will give you free quotation with highly competitive rates. Simply call us or email info@af-acoustics.com

020 3372 4430 Contact us

Please send the following information to us

When calling or emailing us please provide the following data

The development’s location

Where in Woodford is your construction?

Total number of dwellings

Total number of dwellings in the building.

Number of Storeys

For the right calculation of your quotation, tell us how many levels are in your building.

Number of dwellings per floor

To get an appropriate quotation and determine the kind of tests to be conducted, we will also need this.

Kind of structure

Let us know the type of development you have so that we can undertake the required tests for it.

New construction or refurbished building

These two go require different types performance, so let us know which one it is and you’ll get an accurate test and quotation.

Sound testing regulations

We provide sound testing and sound insulation testing on all types of buildings, for compliance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building Standards. Testing can also gain credits for Code for Sustainable Homes and EcoHomes environmental assessment schemes.

Sound resistance: approved document of building regulations (England and Wales)

We can have fully accredited engineers sent to your property at your convenience to provide certification for Building Regulations Part E compliance, recognised by Building Control.

Standard division for developments (Scotland)

In the words of Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests, which are conducted after building utilizing the methodology given in annex 5.C. of the Scottish Standard 5.1 does not apply to: completely disconnected houses, rooftops and walkways with access exclusively for the use of the occupants of the home underneath.

How to get a pass certificate for your sound test

The most effective way to ensure you pass your sound test is to plan the project with sound insulation in mind. This does not need to be costly, and can save considerable time and expense at the end of the project, not to mention avoiding escalating remedial and re-test costs. Are you uncertain that the separating floor and walls you will build will adhere to Document E 2003 conditions? You can book our design services. Our consultation process is led by your project requirements and may include assessment of design reports, test of the development and multiple site visits. The following will give you a better chance of passing the sound test: Windows and internal and external doors are fitted and operable Fit and seal skirting boards Light switches, plug sockets, and light fittings are adequately fixed. Our accomplished acoustic consultants work with developers, planners, contractors, and architects of all sizes from the early stages of the building plan to help limit any potential sound insulation performance problems to the completion of the construction, guaranteeing that all properties meet the criteria of Building Regulations Document E 2003.

Analysis and Report Certificates

We try to issue a certificate to give you the details of the test evaluation and report, by the next day. After the test, our site engineers will provide verbal results and advise you on how to solve potential problem or future areas of concern. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The way the results look

You will get your sound insulation test certificate whether you pass or fail the sound tests. In the event that some part of the building does not meet up with the conditions of Document E, remedial work and a retest is required. We give remedial design advice to help you achieve Building Regulations standards.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed