Sound testing calculates the extent to which sound is blocked by the partition (walls, floors etc) of a building between dwellings. It evaluates the efficiency of the soundproofing materials that make up the structure. It is compulsory for new buildings and refurbishment projects, according to Approved Document E (ADE) updated in 2003.

As many contractors and developers have found to their detriment, without a sound insulation certificate, the Building Control Officer will not issue a completion certificate. As a result of this, we try to ensure that you are issued with a sound insulation certificate as fast as possible. In fact, we pride ourselves on issuing our sound insulation testing certificates as quickly as possible.

Our highly capable sound test engineers will be available on site when you need them. They will give you a verbal result of the test, once taken and a written report will be issued to you by the following working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Insulation Test?

To adhere to Building Regulations ADE requirements, adjoining walls, floors and ceilings in a building will have to be tested, except where licensed Robust Details were used. The airborne and impact sound going through new and old structures are evaluated by sound testing. This can impact adjoining walls and floors between the structures.

What is part of a Sound Insulation Test

Even though sound insulation testing equipment produces lots of noise, sound testing requires quiet conditions and dwellings. Because of this, workers on the site would have to leave during the time of the test, to avoid errors in the test calculation. Sound insulation testing varies by size, complexity and conditions of site tested. Most of the time the test will be conducted in 90 minutes, for a simple, regular sized construction.

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern.

The entire report and individual sound test certificate will be sent to you the day after. Every 10 units in a group or sub-group are to be tested, according to ADE. A sub-group is stipulated in Section 1. Of ADE There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. The volume of testing carried out on each group is written below.

Why is Sound Insulation Testing Relevant?

Document E of Building regulations, from 2003, made it compulsory for all new UK constructions to undertake a pre-completion sound test. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw. This Approved Document, as part of UK Building Regulations helps to ensure that new buildings are constructed to minimum standards that provide reasonable resistance to sound from other parts of the same building and from adjacent buildings. Sound insulation testing is important because sound affects the way we live, whether at work, in the home or whilst at leisure. Noise reduction between walls and floors could result in a more comfortable, productive environment.

Sound insulation and speech privacy are critical for a variety of reasons. Inadequate sound insulation can be extremely distressing to those affected by it. For example, in a block of flats, your upstairs neighbour may (and not unreasonably) like to have friends over at the weekend, resulting in the playing of loud music. However, the downstairs occupant may be working nights and sleeping throughout the day, thus any inadequate sound insulation between these two flats would cause great disturbance and distress to the downstairs occupant. This is just one instance of the influence of sound insulation on our lives. It can be useful in dwellings with neighbouring units/flats/rooms which have diverse purposes, by guaranteeing that an occupant in a room will hear as little noise as possible from the neighbouring room.

How to Know if You Need Sound Insulation Testing

You need a sound insulation test if you’re:

  • Constructing a nursing home or residential rooms like hostel or hotel rooms,
  • Converting a building with a single dwelling into flats,
  • Constructing a property with two or more units,
  • Using designs without Robust Details to build

Building Regulations Part E discusses sound testing in detail and has made it a requirement.

Either you follow the pre-completion sound testing process stipulated therein or you use Robust Details. This way, you have conformed to the requirements. Robust Details are design details for separating elements, which have been tested before to comply with Document E standards. When you use it, you don’t have to take a sound insulation test. However, you must abide strictly by the design from the Robust Details approved list. With sound testing, however, you’re free to pick from any design, including more cost effective and appropriate ones. This makes it a more efficient process than Robust Details. Sound insulation testing can also help architects enhance their building design and in turn the sound insulation of the building.

Cost of Sound Insulation Testing

Contact us and we’ll give you a free quote on the sound test cost based on the requirements of your building. Not only are we highly experienced in providing sound testing services in UK, our reports and certificates get to the client within one of the fastest turnaround time and our prices are competitive. Send us a price you got that’s better than our and we will try to beat it.

Period Sound Insulation Test Should be Carried Out

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. During the test, you should provide the following:

  • Access to all rooms. The only exception is if a schedule was created before the test time.
  • 240V power supply
  • A noiseless site

How is Sound Insulation Testing Done?

Sound insulation testing is not complicated. Our highly qualified engineers will be willing to explain it in detail on the site. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

The test uses a dodecahedron speaker and pink or white noise generator for source sound. The sound source is placed in the largest room of the two. The sound generated and received is measured with a sound level meter. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. For airborne sound tests, two individual speaker positions are used for each source room. Measurements are then made to determine the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact tests are conducted by fixing a tapping machine on the floor. The sound level in the room below it is recorded. Once the calculations are completed and the result is achieved, it is compared with Building Regulations Part E standards. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

Our licensed engineers use UKAS calibrated equipment to measure sound insulation according to the present standards of Building Regulations. An airborne sound test measures levels of sound transmitted through the air through a separating element. We use a loudspeaker and noise generator that produces white or pink noise on one side of the partition, and measure with a sound level meter on both sides to calculate the sound insulation performance of the partition. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. The outcome of the test is written in a report and sent to the customer. This report helps Building Control sign off your building.

A sound test is mandatory for these buildings:

The airborne and impact sound going through new and old buildings are evaluated by sound testing. This can impact adjoining walls and floors between the building.

A new building with 2 or more dwellings

This makes certain that the dwellings have adequate sound proofing.

Converting a single development to flats

When turning the single dwelling into several flats or units, the sound performance requirements of Building Regulations must be met.

Using designs where Robust Details are not included

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. If the building design is slightly different from Robust Details, a sound test is essential so that Building Regulations criteria can be met. A building built as a permanent dwelling has different minimum standards from a building with rooms built for residential purpose, like a hotel or a hostel.

Areas in the UK AF Acoustics Conduct Test

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Worthing. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.

Why you should pick AF Acoustics for your sound testing

Having rendered high quality service to numerous customers in Worthing, we have gotten great positive feedback and recommendation from our clientele due to the following:

Sound testing experience of over 15 years

With more than 15 years of experience, we have a deep knowledge of our customers’ industry and provide actionable strong advice tailored to their needs. Our clients in the UK are completely satisfied with our acoustic solutions. Irrespective of the type of project you have, minor or major, you can be assured that we’ll give outstanding value for your money.

Competitive prices

To make certain that all clients in Worthing can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Worthing. Contact us right now to get a quotation that’s completely free of charge.

Consultancy that is effective and efficient

Our expert acoustic advice is tailored to your specific needs based on our experience which enable us to provide strong solutions. We will give you the right answers and expert guidance so that you can get effectual solutions to your problems.

Test dates that are flexible

We make your convenience our priority. Therefore, we offer flexible alternatives that can help you select test dates that suit you itinerary. Contact us today to get sound testing in Worthing

Test reports arrive the next day

The sooner you get a report on the completed sound insulation test, the sooner you can take appropriate action. We strive to deliver next day reporting in all scenarios regardless of the complexity or size of the project. The report will be detailed and thorough so that all necessities are written out and any advice provided.

Sound insulation services we provide

AF Acoustics offer a variety of complete acoustic slutions to clients all over the Uk, Phone or email us today for more information on how we can help you with your acoustic requirements.

Impact and Airborne floor test

The ceilings/floors of developments undergo impact and airborne floor testing. An impact test measures the levels of noise transmitted directly through a separating construction. Impact and airborne testing is undertaken between party floors.

ADE testing

AF Acoustics sound testing adheres to ADE which stipulates information bearing on the sound resistance and performance of a property. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound insulation test

With our professional and highly skilled expertise, we are willing to work with our clients to help them get a pass certificate in every situation. In new properties, an airborne and impact test will help you guarantee the building meets the requirements of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. When working with AF Acoustics, developers and project managers get acoustic advice right from the start of the building project. That way, they can make sure their developments have a good sound performance. Contact us today for more information about our sound testing services or to book a no obligation quote, free of charge.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Acoustic design testing in schools in line with BB93

Building Bulletin 93 (BB93) explains minimum performance standards for the acoustics of school buildings. It also describes the normal means of demonstrating compliance with the Building Regulations. If you’re developing a new school in Worthing, we can test it to find out if it aligns with BB93.

Acoustic layout

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

It is critical to get right professional assistance ahead of schedule from a highly qualified acoustic specialist. AF Acoustics can assist you with identifying the right acoustic propertiesfor your project at very early on in the construction process and tell you the best way to get them, utilizing a deep know-how of acoustic design.

We can assist with:

Acoustic detail design for architects engaged with residential improvements in consistence with Part E Building Regulations, BS8233 and so on. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Specifications and design details that enable good sound insulation and reduction of noise in residences. Public address and sound reinforcement (conference rooms / lecture theatres etc.)

Get a sound insulation testing quotation by contacting our experts

Our services at AF Acoustics include acoustic design and investigation, evaluation and calculation of noise, acoustic survey, building an architectural acoustics and air pressure testing. Our professional guidance and advice is provided to private individuals, businesses and government agencies amongst others. You can contact us by sending us an email on info@af-acoustics.com or calling us for a free quote.

020 3372 4430 Contact us

Giving the following information to us will be helpful

In your email or during your phone call, tell us about the following

Place where the building is being built

Where is your development situated in Worthing

Total number of dwellings

Number of dwellings on the property

Number of floors in the building

For the right calculation of your quotation, tell us how many levels are in your building.

Configuration of dwellings (no. of units per level)

This will also be needed to determine scope of the testing and provide an accurate quote

Type of development

The type of building, as different building types typically require a different testing.

Newly completed construction or conversion

The testing requirement for new builds and conversion projects are different. We will need this information to determine what standard the testing ought to follow. With this information, we can easily provide you with an accurate and competitive quote on your project in little time.

Building regulations for sound test

Get more credits for Code for Sustainable Homes and EcoHomes environmental assessment project by taking a sound insulation test which are aligned with approved document E building regulations rules.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

We can send our authorised engineers to your development whenever the timing is ideal to undertake sound insulation testing that conforms to Building Regulations Document E consistence, as accepted by Building Control.

Scotland Standard division for properties

According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” The following are exempt from the testing techniques given in annex 5.C. of the Scottish Standard and Standard 5.1 – completely segregated rooftops, houses or walkways whose access is only used for upkeep or for the utilization of the inhabitants of the dwelling beneath.

How to get a pass certificate for your sound test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. Are you uncertain that the separating floor and walls you will build will adhere to Document E 2003 conditions? You can book our design services. The degree of guidance you require can vary, from site visits and comprehensive design reports, to simpler initial testing to know the starting point for construction. The following criteria should be followed to provide you with the best chance of passing your sound test: Inner and outer doors and windows have been installed and can be used Skirting boards are fixed are sealed Light switches, light fittingsand plug sockets are properly fitted Our accomplished acoustic consultants work with developers, planners, contractors, and architects of all sizes from the early stages of the building plan to help limit any potential sound insulation performance problems to the completion of the construction, guaranteeing that all properties meet the criteria of Building Regulations Document E 2003.

Test report certificates

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern. A full report and individual sound test certificates can be generated and sent out usually the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The results

A certificate will be issued to you whether the sound insulation treatment of the building meets the requirements of Document E of Building Regulations or not. In the event that some part of the building does not meet up with the conditions of Document E, remedial work and a retest is required. We give remedial design advice to help you achieve Building Regulations standards.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed