Sound insulation testing is used to measure the resistance of sound provided by an element of a building (such as a floor or wall) between dwellings. It essentially measures the effectiveness of the sound proofing treatment installed as part of a build or property development. The Building Regulations Approved Document E (ADE) states all new dwellings and renovated constructions should undergo sound testing.

At the completion of the test, a sound insulation certificate is issued. Without the certificate, Building Control will not release the building completion certificate to the contractors and developers of the project. We understand how important it is for you to get a sound insulation certificate. That’s why we go the extra mile to make sure you get your certificate as quickly as possible. When the tests are completed, we work quickly to issue your certificates; we take great pride in our efficiency.

AF Acoustics’ competent and well-trained engineers, who will be available for testing, can even let you know the verbal results of your sound test. You will receive a written report in the space of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

How Sound Testing Works

In order to comply with Part E of the Building Regulations, developments will require the testing of separating walls and floors. The only exception is where Robust Details have been used. Sound testing measures the impact and airborne sound moving through new and old adjoining buildings. This tests include the boundary walls between buildings and in-between the spaces in a development.

What is part of a Sound Insulation Test

The sound test itself produces very high levels of noise but also requires relatively quiet conditions on site. For these reasons, any workforce in the testing area will have to leave temporarily to ensure test accuracy. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. Generally, a sound insulation test takes about 90 minutes for a simple, regular sized project.

After the test, the sound insulation test engineers will let you know the outcome of the test and supply simple feedback of important things noted during the test; e.g. problems that might occur in the future.

A full and thorough report with the certificate of the test will be given to you within 24 working hours. The sound insulation testing methodology has been outlined by Document E of the Building Regulations. The document states that every 10 units in a sub-group or group should undergo one set of test, and defines a sub-group in Section 1. Buildings are divided into three kinds for the test – houses, flats and rooms built for or converted to residential dwellings, like student accommodation, care homes and hotel rooms. The extent of testing required for these three groups is shown below.

Why Should Your Dwelling Undergo Sound Testing

Document E of Building regulations, from 2003, made it compulsory for all new UK constructions to undertake a pre-completion sound test. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result. This Approved Document, as part of UK Building Regulations helps to ensure that new buildings are constructed to minimum standards that provide reasonable resistance to sound from other parts of the same building and from adjacent buildings. Sound insulation testing is important because sound affects the way we live, whether at work, in the home or whilst at leisure. Noise reduction between walls and floors could result in a more comfortable, productive environment.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. For example, in a block of flats, your upstairs neighbour may (and not unreasonably) like to have friends over at the weekend, resulting in the playing of loud music. However, the downstairs occupant may be working nights and sleeping throughout the day, thus any inadequate sound insulation between these two flats would cause great disturbance and distress to the downstairs occupant. This is just one example of how sound insulation can affect the quality of life of people in different ways. Then there are developments where each neighbouring room / flat / unit has mixed uses. If the development has passed the sound insulation test, noise is reduced to a minimum.

Does Your Development Need a Sound Insulation Test?

You need sound insulation testing if you:

  • Build a new development of 2 or more dwellings / flats
  • Convert a former single dwelling into flats
  • Build a Nursing Home or rooms for residential use, i.e. hotel or hostel
  • Have designs which do not adhere to Robust Details

Document E of the Building Regulations explains sound insulation testing and makes it a necessity.

To conform, you can either follow the procedure outlined in ADE or make use of Robust Details. Robust details are separating elements that have been pre-tested and conform to Approved Document E sound insulation standards. You also cannot expand or tweak the design from the Robust Detail Approved listing. However, you are exempt from the sound test. Sound testing provides more flexibility by allowing different designs and is often therefore more cost effective in many ways compared to the Robust Details Scheme. It also gives architects the opportunity to evaluate their design and give your structure a much better sound insulation which will increase sound performance.

How Much Will I Pay for a Sound Insulation Test?

We can send quotation that’s completely free of charge and is based on the kind of development you have. We have handled all kinds of sound insulation projects in UK and issue a report and certificate as quickly as possible. Our prices are affordable too and can beat others.

Ideal Period for a Sound Insulation Test

The best time for a sound insulation test is just before the construction of the property is finished and after all windows and doors are fixed. However, in the case of a problem we can take the test before then. These are the things we need to conduct the test:

  • 240V power supply
  • A quiet environment
  • Access to all the units of the structure unless places to test have been decided before then.

How is sound insulation testing carried out?

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. For partition walls, airborne tests are carried out. For floors there are two types, airborne and impact tests.

The source sound is produced with a white or pink noise generator with a dodecahedron speaker in the largest room. The noise from the source room and received by the receiver room, and background noise is measured with a sound level meter. The meter is also used to measure the background sound, to ensure that it’s 10dB lower than the source sound, as is the standard. More background sound leads to creating a higher source sound. For airborne tests, two speakers positions are used in the source room and the level of noise entering into the receiving partition room is measured. That way the difference in sound level is calculated.

This difference is modified to include background noise in the receiver room and reverberation time – time whereby a sound fades away in a closed space by 60dB. Impact tests are conducted by fixing a tapping machine on the floor. The sound pressure level at the receiving room, which is below the source room, is measured. Calculations are undertaken, and results achieved. The results are crosschecked to ensure they meet Document E of Building Regulations target. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

Our high-tech sound insulation machines are UKAS calibrated and our accredited expert engineers conduct the test using Building Regulations present criteria. An airborne sound test measures levels of sound transmitted through the air through a separating element. We use pink or white noise generator and speakers on one side of the partition. A sound level meter is used on calculating sound in both units. For impact test, a tapping machine that makes impact sound by dropping metal hammers is used. A sound level meter is used to measure in the receiving room below the room the tapping machine is in. Testing can only be completed on ‘habitable’ rooms. Habitable rooms can be bedrooms, lounges, living rooms and open plan kitchen/ living spaces. The outcome of the test is written in a report and sent to the customer. This report helps Building Control sign off your building.

It’s important to undertake a sound test if you have this kind of building:

Sound testing measures the impact and airborne sound moving through new and old adjoining buildings. This could affect the separating walls between buildings or in-between the spaces in a development.

Two or more new build dwellings or flats

This makes sure that the sound insulation for the building meets all the necessary requirements.

Conversions of former single dwelling properties into flats

When turning the single dwelling into several flats or units, the sound performance requirements of Building Regulations must be met.

Design that don’t have Robust Details factored in

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. If the building design is slightly different from Robust Details, a sound test is essential so that Building Regulations criteria can be met. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Where doses AF Acoustics conduct tests in UK?

AF Acoustics provides acoustic design services to customer nationwide, especially in Leighton-Buzzard. Our clientele base includes architects, planning and environmental consultancies, private individuals and government agencies. Our consultants can be found in various places in the south east region. This way you get an affordable price.

Why choose AF Acoustics for Sound Insulation Testing?

We have worked with many organisations and individuals in Leighton-Buzzard. Our clients have endorsed us for the following reasons:

Over 15 years’ experience

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. By doing this, we have been able to continuously satisfy clients in the UK and meet their acoustic needs for over 15 years, providing great value for money.

Competitive prices

To make certain that all clients in Leighton-Buzzard can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Leighton-Buzzard. Contact us right now to get a quotation that’s completely free of charge.

Consultancy that is effective and efficient

We will listen to your wishes, provide you sturdy solutions and deliver acoustic consultancy through our expertise. When you reach out to us for professional advice, we make certain that we render accurate solutions rapidly. We suggest productive answers that handle your present and long-term desires to the maximum.

Adjustable test dates

We make your convenience our priority. Therefore, we offer flexible alternatives that can help you select test dates that suit you itinerary. If you want to schedule sound insulation testing in Leighton-Buzzard, phone or email us immediately.

Next day reporting

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. We make certain all relevant issues are covered and quality tips are supplied by detailing all the aspects of the test in the report.

Sound Insulation Testing Services We offer

AF Acoustics provide a scope of exhaustive and detailed acoustic solutions for clients across the country, making certain our techniques have the best quality and performance. Phone or email us today for more information on how we can help you with your acoustic requirements.

Airborne and impact tests for floors/ceilings

Impact and airborne floor tests are conducted on ceilings/floors between rooms. The measurement of the extent of noise transmitted directly through impact from one adjoining room to another is known as impact testing. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

Approved Document E test

Our sound insulation testing in accordance with Building Regulations Approved Document E, which sets out details pertaining to the resistance to the passage of sound. For new buildings, results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. Converted structures expected impact sound results increases by 2dB L’nTw while the airborne sound results reduces by 2dB DnTw+Ctr.

Sound testing

We want to give our customers the most highest chance to acquire a pass and via our offer skilled services. A new dwelling may have to undergo an airborne and impact test to meet the benchmark of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly provide consultations for project managers and developers from the very start of developments, ensuring peace of mind when it comes time to having a sound test. To find out more about our sound testing services and get a free quotation, contact us now.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 testing of acoustic design in schools

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. If you’re developing a new school in Leighton-Buzzard, we can test it to find out if it aligns with BB93.

Acoustic plan

AF Acoustics give definite design services and consultancy services to all types of developments. We create bespoke solution and can provide information on the best available acoustic products. We will tailor our design solutions to your project.

As anyone who has had to deal with the acoustic properties of a building will know, it’s important to get the correct advice, as early as possible from a good acoustic consultant. AF Acoustics can help you to identify the correct acoustic requirements for your project at an early stage and advise on the best means to meet them using expert knowledge of acoustic design.

We are able to help with:

Acoustic detail design for architects involved in residential developments for compliance with Part E Regs, BS8233, and so on. Detail plans for the educational, commercial and healthcare industry so as to meet with the current criteria. Specifications and design details that enable good sound insulation and reduction of noise in residences. Public address and sound reinforcement system

Contact AF Acoustics specialist for sound insulation test quotes

We are an independent acoustic organisation that handles everything concerning acoustics including survey, design, architectural and building acoustics and air tightness testing. We want to give you expert guidance and provide working solutions, whether you are an individual or an organisation. For a quotation, call or email info@af-acoustics.com

020 3372 4430 Contact us

Please send the following information to us

When contacting us, please give us the following information

Location of property

Where is your property located in Leighton-Buzzard?

Number of dwellings in the building

Total number of dwellings in the structure

Number of Storeys

For an accurate calculation of the quote, tell us the number of storeys

Dwellings arrangements per level

Tell us how many units are in your structure so that we can give you the right calculation for your quotation and know the scope of the test.

Building type

The type of building, as different building types typically require a different testing.

Newly completed construction or conversion

Knowing if your building is new or converted allows us to give you a competitive quotation and prepare the right test for it.

Sounds test in accordance with building regulations

Our sound insulation tests are conducted in accordance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building requirements. You can also get credits for Code for Sustainable Homes and EcoHomes environmental assessment projects.

Sound resistance: approved document of building regulations (England and Wales)

Our certified engineers can come to your building whenever it might suit you to undertake sound insulation testing to Part E of Building Regulations adherence, recognised by Building Control.

Scotland Standard division for properties

According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Fully detached roofs or walkways that are not used for residential purposes do not have to take the sound tests of the Scottish Standards 5.1.

How to make sure you pass your sound test

Make sure you pass your sound test by having efficient sound insulation included in the building design. It saves time and money and helps you avoid repair work and re-test expenses. We offer design services that help you construct separating walls and floors with good sound performance that meet ADE demands. Our consultation process is led by your project requirements and may include assessment of design reports, test of the development and multiple site visits. Take the following action to give your building the best opportunity to pass the sound insulation test: All windows and doors have been fitted and work Skirting boards are fitted Fix all light switches, light fittings and plug sockets. Our expert acoustic consultants work with planners, developers, architects and contractors from the beginning of the design stage till when the property is finished to ensure it meets the conditions of Document E 2003.

Test and report certificates

To obtain a thorough evaluation of your building, we issue a report certificate within 24 working hours where possible. Our highly capable sound test engineers will give you a verbal result of the test, once the test is taken and proffer solutions to possible problems or future areas of concern. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The results

Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. In the event that some part of the building does not meet up with the conditions of Document E, remedial work and a retest is required. We give remedial design advice to help you achieve Building Regulations standards.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed