Sound insulation testing involves the use of specialist equipment to examine how much sound is reduced off by floors and walls, of a building. It checks if a dwelling’s sound proofing treatment meets the requirements set out in Approved Document E. New structures and reconstructed developments have been mandated by the Building Regulations to test for sound upon completion, since Approved Document E (ADE) was reappraised in 2003.

Not having a sound insulation certificate issued after a test, has resulted in additional costs and expenses for developers. Any development that has not taken a sound test will not be given a completion certificate by Building Control. Because we understand how the sound insulation certificate affects your building project, we ensure that you get it as quickly as possible after the test. We take great pride in providing our certificates to you as soon as possible after the tests.

Our highly qualified site engineers can arrive on site when needed. They will provide verbal results after the test and a written report will be sent to you within 24 working hours.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Testing Does

Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

What is part of a Sound Insulation Test

While producing lots of noise, sound test needs a quiet site to be conducted efficiently. Due to this fact, the workers in the site should not be present at the time of the test. Sound insulation testing varies by size, complexity and conditions of site tested. Most of the time the test will be conducted in 90 minutes, for a simple, regular sized construction.

Once this is done, the sound test engineers give temporary results while they’re still on the site. They will also provide suggested solutions to possible problem areas noted during testing.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. Every 10 units in a group or sub-group are to be tested, according to ADE. A sub-group is stipulated in Section 1. Of ADE Buildings are divided into three kinds for the test – houses, flats and rooms built for or converted to residential dwellings, like student accommodation, care homes and hotel rooms. How much testing that should be done on each group is listed below:

Why Sound Testing is Required

Sound insulation testing is required because ADE of Building Regulations has made it compulsory for all new buildings to take a sound test prior to finishing construction. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. ADE ensures that new building are resistant to noise from adjoining buildings and other rooms within the same building. When sound resistance is high in party walls and floors, the environment is more comfortable, since sound affects every aspect of our lives – work environment, home environment and while relaxing. This is why sound testing is crucial.

Insufficient sound insulation causes distress and comfort while an effective sound insulation system brings about speech privacy. This is one of the several reasons why sound insulation is a key element in building. For instance, in an apartment building, the neighbour upstairs might invite friends over during the weekend and put on loud music. The inhabitant downstairs might spend night hours as work time. If the sound insulation is inefficient, this could lead to lots of problems. Sound insulation impacts people’s lives in various ways. Sound insulation is also effective in buildings that have flats with mixed uses. If the building passed the sound test, you can be sure that noise reduction will be effective.

Do You Need a Sound Test?

Are you converting your property into several units? Does your design not use Robust Details? Are you constructing a new building with more than two rooms? Are you building a nursing home or rooms that will used for residential purposes, like hotels and hostels? If so, your structure needs to undergo a sound test. ADE thoroughly explains sound testing and makes it compulsory.

All you have to do is follow the guidelines listed in the document or pay to use Robust Details and you will have fulfilled the requirements. Robust Details are a set of specific design details for walls and floors that have been previously tested to show compliance and must be used if this route is selected. When you use it, you don’t have to take a sound insulation test. However, you must abide strictly by the design from the Robust Details approved list. This becomes difficult when you need to pick a more appropriate or cost-effective design that will suit your needs. Sound tests enable you do that, making it more flexible. On-site pre-completion sound insulation testing gives architects more insight and ability to make their design lead to constructions that have a higher sound performance.

Cost of Sound Insulation Testing

We can send quotation that’s completely free of charge and is based on the kind of development you have. We have worked throughout the country on all sizes of project, and should a sound insulation report and certificates be required, we can provide the fastest turnaround times and most competitive prices available. If you get a better quote elsewhere, simply forward it to us and we will try and beat it!

Sound Insulation Test Time

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. To be able to conduct sound insulation testing we require the provision of a 240V power supply, and a quiet site (a noisy site can make conducting the tests extremely difficult). Access will be required to all rooms of the development unless a test schedule is determined in advance.

The Procedures of a Sound Insulation Test

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. The separating walls undergo airborne tests while separating walls and floor undergo airborne and impact tests.

A pink or white noise generator and a large speaker is used for the test in the biggest room between the two undergoing testing. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. The background noise level is also measured. The higher the background noise then the higher the source noise will need to be set, since the resulting noise level in the receiver room needs to be 10dB higher than the background noise at all measured frequencies. Airborne sound testing is done in a similar way. First, two speaker positions are used for each source room. Then, the level of sound in the receiver room is measured so that the difference in noise level between the two rooms can be calculated.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. A tapping machine is placed on the floor to execute an impact sound insulation test. The room under it is then measured for the noise levels. Calculations are undertaken, and results achieved. The results are crosschecked to ensure they meet Document E of Building Regulations target. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. Airborne sound test is the measurement of sound moving through the air through a wall or floor. We use pink or white noise generator and speakers on one side of the partition. A sound level meter is used on calculating sound in both units. For impact test, a tapping machine that makes impact sound by dropping metal hammers is used. A sound level meter is used to measure in the receiving room below the room the tapping machine is in. The tests are administered in room with residential purposes. For example, kitchens/living spaces, lounges, bedrooms and living rooms. You will get the test results in a report within a working day. This report can be used to help sign off your building as it is accepted by Building Control.

Sound insulation testing is essential for these dwelling types:

Sound insulation tests examine airborne and impact sound moving through buildings. It is usually undertaken between party walls and floors between buildings or between spaces within a new development.

A structure with 2 or more units/flats

This is to ensure that the sound proofing of the building is up to standard for residential purposes.

A single dwelling that was turned into a development with several flats or units

All the units that have been built are to be constructed in alignment with Part E of Building Regulations.

Using designs where Robust Details are not included

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the building design is slightly different from Robust Details, a sound test is essential so that Building Regulations criteria can be met. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Towns in the UK AF Acoustics Services can be Found

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Gerrards-Cross. Af Acoustics work with individuals, government agencies, planning and environmental consultancies, and architects. We’re based in several areas across the south east region of UK so that we can give you the most cost effective quote in the industry.

Why you should pick AF Acoustics for your sound testing

We have worked with many organisations and individuals in Gerrards-Cross. Our clients have endorsed us for the following reasons:

15 years’ experience

Our experience of over 15 years has enabled us understand our clients need and industry extensively. As a result, our advice is applicative, serviceable and will meet the client at the point of their needs. We have over 15 years of experience satisfying the acoustic needs of UK businesses and homeowners with a proven track record on both small scale and major projects. You can always rely on us for exceptional value for money.

Great prices

We want to ensure that you get the best value for your money. That is why we have one of the most unbeatable rates in and outside Gerrards-Cross. Call us or email today to get a free quotation.

Consultancy that is effective and efficient

We will listen to your wishes, provide you sturdy solutions and deliver acoustic consultancy through our expertise. When you reach out to us for professional guidance, we make it a priority and deliver accurate answers fast. We recommend effective solutions that are most in line with your current and long-term needs.

Test dates that are adaptable

Our test date options let you pick what will suit your schedule because your comfort is essential to us. Take the first step towards your sound insulation testing in Gerrards-Cross by calling us now.

Get your test reports quickly

The sooner you receive the details of your sound insulation test results, the sooner you can get your building signed or remedy any problems. We endeavour to give you the report the following working day in all situations, even when the project is complex and large in size. That way, you can take immediate action on the recommendations given. Our reports are thorough and cover all the important issues.

Sound insulation testing services AF Acoustics undertake

AF Acoustics provide a scope of exhaustive and detailed acoustic solutions for clients across the country, making certain our techniques have the best quality and performance. Phone or email us today for more information on how we can help you with your acoustic requirements.

Impact and airborne tests for floors

These are taken on separating floors/ceilings between residences. Impact testing evaluates how much the sound flowing from one partition to another through party floors via impact is. Impact and airborne testing is undertaken between party floors.

Approved Document E test

Our sound insulation testing in accordance with Building Regulations Approved Document E, which sets out details pertaining to the resistance to the passage of sound. The impact sound test of new dwellings should be 62dB L’nTw or less and airborne sound insulation 45dB DnTw+Ctr or more while impact results for reconstructed properties should be 64dB L’nTw and airborne sound insulation 43dB DnTw+Ctr or more.

Sound test

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. In newly completed constructions, an airborne wall test and an airborne and impact floor test will be needed to meets the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. If you’re constructing a new school in Gerrards-Cross, we can test the sound performance to evaluate if it meets the standards of BB93.

Acoustic layout

AF Acoustics provide detailed acoustic design services and consulting on a wide range of buildings. We have the capability and experience to develop customised solutions, and have a strong working knowledge of available proprietary acoustic products. We will develop detailed design solutions suitable for the specific demands of the project.

Getting advice on the acoustics of a development as early as possible is crucial. AF Acoustics can enable you to do that by advising you on the appropriate acoustic requirements of your property very early in the building process and recommending what to do to fulfil them.

We can assist with:

Acoustic detail layout for architect developing structures complying to Building regulations, BS8233 and so on. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Designs and specifications that ensure good sound performance of buildings in residential areas and other noise sensitive places. Increasing sound through public enterprise and sound reinforcement systems in conference rooms, halls, lecture theatres and the like.

Call Our Experts Now For A Sound Insulation Testing Quote

We are an independent acoustic organisation that handles everything concerning acoustics including survey, design, architectural and building acoustics and air tightness testing. We will give you sound advice and guidance no matter who you are or the kind of project you have. To get an accurate quotation, either call us or email info@af-acoustics.com

020 3372 4430 Contact us

We will need the following information:

In your email or during your phone call, tell us about the following

Construction’s location

Where is your property located in Gerrards-Cross?

How many dwellings are there?

Total number of dwellings in the building.

How many storeys are there?

To get a precise quote, let us know the total number of floors you have.

Number of dwelling units per storey

How many units are on each floor? Knowing this will help us give you an appropriate quotation.

Types of construction

What is your building type? This will help us know the kind of test it will undergo.

New property or reconstructed dwelling

The testing requirements for new dwellings and converted properties are not the same. Tell us the type of building you have so that we give you the right quote.

Sounds test in accordance with building regulations

Our ADE compliant sound tests can help you gain credits for Code for Sustainable Homes and EcoHomes environmental assessment structures.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

Our expert engineers can issue certificates for the sound insulation testing. They can visit the site and conduct the test that will lead to getting a certificate which is in line with Building Regulations and Building Control requirements.

Scotland Standard division for properties

According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be taken at the completion of the building, using procedures given in annex 5.C. of the Scottish Standards. These standards don’t apply to detached structures that have access only for maintenance or are to used only by the occupants who live below.

How to pass a sound test

The most effective way to ensure you pass your sound test is to plan the project with sound insulation in mind. This does not need to be costly, and can save considerable time and expense at the end of the project, not to mention avoiding escalating remedial and re-test costs. If you are unsure of how to build the separating floor and wall constructions and associated junctions across your development to satisfy the requirements of Document E 2003, we can offer design advice. Whether you want some initial tests on your project, or comprehensive reports at the end, we can help you at the level that you need. The following conditions will provide you with an ample chance of passing the sound test: All windows and doors have been fitted and work Skirting boards are fixed Light switches, light fittingsand plug sockets are properly fitted Our professional acoustic professionals work with contractors, architects, developers, and planner from the beginning of the design to make sure that all requirements are met.

Test and report certificates

After the test, AF Acoustics’ competent and well trained engineers can let you know the verbal results of your sound test and provide feedback on issues noticed during the test. We endeavour to send an investigation and report certificate the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What do the results look like?

You will get your sound insulation test certificate whether you pass or fail the sound tests. If parts or all the building fails the test, repair work and a retest is recommended. We provide design advice to ensure your property does proper remedial and meets up with the necessary requirements.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed