Sound insulation testing is used to measure the resistance of sound provided by an element of a building (such as a floor or wall) between dwellings. It essentially measures the effectiveness of the sound proofing treatment installed as part of a build or property development. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

Building Control does not issue completion certificates to buildings that don’t have a sound insulation certificate. Contractors and developers have sometimes discovered this, to their detriment. Because we understand how the sound insulation certificate affects your building project, we ensure that you get it as quickly as possible after the test. In fact, we are proud of our turnaround times and our team will issue your certificates as quickly as we possibly can.

Even before you get the certificate, you will receive the results of the test. First, our skilled and competent sound insulation test will engineers give you a verbal result at the site. Then, a written report is sent to you within 24 hours of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Does

Developments must test all walls, floors and ceilings that separate buildings or neighbours in a dwelling, to conform to Approved Document E (ADE) of the Building Regulations. You may not have to test your building if you used Robust Details which were approved before their installation. Sound Insulation Testing tests for both the airborne sound and the impact sound which travels through new or existing buildings . The tests cover party walls and floors between new and existing buildings, or between spaces within a new development entirely.

What is involved in a Sound Test

Even though sound insulation testing equipment produces lots of noise, sound testing requires quiet conditions and dwellings. Because of this, workers on the site would have to leave during the time of the test, to avoid errors in the test calculation. Sound insulation testing varies by size, complexity and conditions of site tested. Most of the time the test will be conducted in 90 minutes, for a simple, regular sized construction.

After the test, the sound insulation test engineers will let you know the outcome of the test and supply simple feedback of important things noted during the test; e.g. problems that might occur in the future.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. How much testing that should be done on each group is listed below:

Why is Sound Insulation Testing Required? Why is it Important?

Before completing a building, all new constructions should be tested for sound insulation, as stipulated by Approved Document E since 2003. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. These result limits were put in to create and maintain a uniform standard for sound resistance in different parts of a dwelling and between adjacent buildings. Sound insulation testing is important because sound affects the way we live, whether at work, in the home or whilst at leisure. Noise reduction between walls and floors could result in a more comfortable, productive environment.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. Sound insulation helps improve the quality of a person’s life in diverse ways. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

Do I Need a Sound Insulation Test?

If you’re doing one of the following, then you need a sound test:

  • Constructing a building that has two or more units
  • Constructing a nursing home or rooms that will be lived in, e.g. hotel room or hostel
  • Converting a single development to flats
  • Using designs where Robust Details are not included

Building Regulations Part E discusses sound testing in detail and has made it a requirement.

All you have to do is follow the guidelines listed in the document or pay to use Robust Details and you will have fulfilled the requirements. If you choose the latter, you must use Robust Details which are a approved design details for partitioning walls and floors. When you use it, you don’t have to take a sound insulation test. However, you must abide strictly by the design from the Robust Details approved list. With sound testing, however, you’re free to pick from any design, including more cost effective and appropriate ones. This makes it a more efficient process than Robust Details. On-site pre-completion sound insulation testing gives architects more insight and ability to make their design lead to constructions that have a higher sound performance.

How Much Will I Pay for a Sound Insulation Test?

Simply contact us and we will be able to provide a free, no obligation quotation as to the requirements and costs for your development. Not only are we highly experienced in providing sound testing services in UK, our reports and certificates get to the client within one of the fastest turnaround time and our prices are competitive. Send us a price you got that’s better than our and we will try to beat it.

Period Sound Insulation Test Should be Carried Out

The best time for a sound insulation test is just before the construction of the property is finished and after all windows and doors are fixed. However, in the case of a problem we can take the test before then. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

How is sound insulation testing carried out?

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. Airborne tests are conducted on party walls while impact and airborne tests are conducted on party floors.

The source sound is produced with a white or pink noise generator with a dodecahedron speaker in the largest room. A sound level meter is then used to take noise measurements within the source room and the receiver room. Background noise is measured to make certain that the source noise is greater. This way the standard of the receiver room having a 10dB higher noise level at all calculated frequencies can be realised. Airborne sound testing is done in a similar way. First, two speaker positions are used for each source room. Then, the level of sound in the receiver room is measured so that the difference in noise level between the two rooms can be calculated.

The variations or differences in noise level are ‘corrected’ to take into consideration the already present background noise in the receiving room and the reverberation time – measure of time needed for a sound to decay or be absorbed in a closed room by 60dB. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. The sound pressure level at the receiving room, which is below the source room, is measured. Calculations are done and the outcome is checked against ADE requirements for the type of building. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

Our accredited engineers are testing to the current standards. We use only UKAS calibrated equipment, as stated by the building regulations. An airborne test is used to check how much sound is moving through the air between partitions. We use a loudspeaker and noise generator that produces white or pink noise on one side of the partition, and measure with a sound level meter on both sides to calculate the sound insulation performance of the partition. For impact sound testing, the equipment used is a tapping machine that uses dropping hammers to create noise and a sound level meter. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. Test results, which are approved by Building Control and used to sign off the building, are recorded in a report and sent to the client.

These kinds of properties should undergo a sound insulation test:

For sound testing we usually undertake impact and airborne sound test on buildings. This affects the separating floors and walls between habitable rooms of buildings and developments.

A new building with not less than two rooms

This ensures that a sound insulation system installed in residences meets the requirements of ADE.

A single dwelling that was turned into a development with several flats or units

The transformation of a single dwelling property into flats must adhere to the sound insulation standards of Building Regulations.

Designed in a way that does not adhere to Robust Details

Architects are able to use pre-tested and approved Robust Details design for partitioning walls and floors. The Robust Details scheme was formed in 2004 by Robust Details Ltd. If the building design does not strictly adhere to Robust Details, a sound insulation test becomes necessary to meet Building Regulations. A building built as a permanent dwelling has different minimum standards from a building with rooms built for residential purpose, like a hotel or a hostel.

Which areas of the UK does AF Acoustics cover?

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Kington. Our clients include architects, planning and environmental consultancies. We also work with government agencies and private individuals. We’re based in several areas across the south east region of UK so that we can give you the most cost effective quote in the industry.

Why you should choose AF Acoustics

Our sound insulation testing expertise at AF Acoustics have aided several home and business owners in Kington. We come highly recommended by our clients because of the guarantees when you work with us

Sound testing experience of over 15 years

Our experience of over 15 years has enabled us understand our clients need and industry extensively. As a result, our advice is applicative, serviceable and will meet the client at the point of their needs. Our clients in the UK are completely satisfied with our acoustic solutions. Irrespective of the type of project you have, minor or major, you can be assured that we’ll give outstanding value for your money.

Best rates available

Compared to other sound insulation testing service in Kington, our prices are extremely competitive. This is because we want you to be able to afford the best expert sound testing service there is. To get a free quote for your dwelling, contact us today.

Effective and quick consultancy

We will listen to your wishes, provide you sturdy solutions and deliver acoustic consultancy through our expertise. When you reach out to us for professional advice, we make certain that we render accurate solutions rapidly. We suggest productive answers that handle your present and long-term desires to the maximum.

Test dates that are adaptable

Your convenience is also important to us. This is why we offer you flexible options that let you pick test dates that are most convenient for you. If you want to schedule sound insulation testing in Kington, phone or email us immediately.

Next day reporting

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. The conveyed report will be exhaustive, covering every issue point by point to guarantee that the best suggestions are given.

Sound insulation services we provide

We offer a wide range of thorough acoustic solutions for our clients nationwide, and we ensure a high calibre and effective approach. Phone or email us today for more information on how we can help you with your acoustic requirements.

Airborne and impact ceilings/floor tests

These are only carried out on separating floor/ceiling between dwellings. An impact test examines the level of noise moving from one dwelling to another through impact on adjoining floors/ceilings. Impact and airborne testing is undertaken between party floors.

ADE testing

AF Acoustics sound testing adheres to ADE which stipulates information bearing on the sound resistance and performance of a property. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound testing

Our services and expertise is unbeatable and we are glad to work with our clients to help pass their sound insulation tests. To make sure a new residence meets with the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw, an airborne wall test and an airborne and impact floor test will need to be conducted. We regularly provide consultations for project managers and developers from the very start of developments, ensuring peace of mind when it comes time to having a sound test. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. If you’re constructing a new school in Kington, we can test the sound performance to evaluate if it meets the standards of BB93.

Acoustic plan details

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

When constructing a building, it’s vital you get advice from the right acoustic consultant on time. AF Acoustics uses professional expertise to discover your acoustic needs early on and proffer ideas on how to meet them.

We can help with:

Acoustic detail plan for architects associated with advancements on residences adhering to ADE, BS8233, etc. Detail plans for the educational, commercial and healthcare industry so as to meet with the current criteria. Specifications and design details that enable good sound insulation and reduction of noise in residences. Improving sound and public address system in halls, conference rooms etc.

Call Our Experts Now For A Sound Insulation Testing Quote

AF Acoustics is a leading acoustic consultancy. It provides the following services: architectural and building acoustics, acoustics design, survey and investigation in the field of planning and noise, and examining and controlling air vibrations while conducting air leakage tests. Our professional guidance and advice is provided to private individuals, businesses and government agencies amongst others. You can contact us by sending us an email on info@af-acoustics.com or calling us for a free quote.

020 3372 4430 Contact us

Giving the following information to us will be helpful

In your email or during your phone call, tell us about the following

Location of development

Where in Kington is your construction?

How many dwellings are there?

Number of dwellings on the property

Total number of floors

For the right calculation of your quotation, tell us how many levels are in your building.

Number of dwellings per floor

This will also be needed to determine scope of the testing and provide an accurate quote

Type of development

What is your building type? This will help us know the kind of test it will undergo.

New dwelling or converted property

The testing requirements for new dwellings and converted properties are not the same. Tell us the type of building you have so that we give you the right quote.

Building regulations for sound test

Our ADE compliant sound tests can help you gain credits for Code for Sustainable Homes and EcoHomes environmental assessment structures.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

Our expert engineers can issue certificates for the sound insulation testing. They can visit the site and conduct the test that will lead to getting a certificate which is in line with Building Regulations and Building Control requirements.

Scotland Standard division for properties

Section 5.1 of the Scottish Building Standards states “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” The following are exempt from the testing techniques given in annex 5.C. of the Scottish Standard and Standard 5.1 – completely segregated rooftops, houses or walkways whose access is only used for upkeep or for the utilization of the inhabitants of the dwelling beneath.

Passing a sound insulation test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. If you are unsure of how to build the separating floor and wall constructions and associated junctions across your development to satisfy the requirements of Document E 2003, we can offer design advice. Our consultation may include several site visits and thorough design reports, or more basic initial tests on your structure. The following conditions will provide you with an ample chance of passing the sound test: Install and make sure that all external and internal doors and windows are operational Skirting boards are fixed Light switches, plug sockets, and light fittings are adequately fixed. Our expert acoustic consultants work with planners, developers, architects and contractors from the beginning of the design stage till when the property is finished to ensure it meets the conditions of Document E 2003.

Investigation and report certificates

To obtain a thorough evaluation of your building, we issue a report certificate within 24 working hours where possible. Our highly capable sound test engineers will give you a verbal result of the test, once the test is taken and proffer solutions to possible problems or future areas of concern. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The results

A certificate will be issued to you whether the sound insulation treatment of the building meets the requirements of Document E of Building Regulations or not. In the event that some part of the building does not meet up with the conditions of Document E, remedial work and a retest is required. We give remedial design advice to help you achieve Building Regulations standards.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed