Sound insulation testing involves the use of specialist equipment to examine how much sound is reduced off by floors and walls, of a building. It checks if a dwelling’s sound proofing treatment meets the requirements set out in Approved Document E. New structures and reconstructed developments have been mandated by the Building Regulations to test for sound upon completion, since Approved Document E (ADE) was reappraised in 2003.

Not having a sound insulation certificate issued after a test, has resulted in additional costs and expenses for developers. Any development that has not taken a sound test will not be given a completion certificate by Building Control. As a result of this, we try to ensure that you are issued with a sound insulation certificate as fast as possible. In fact, we are proud of our turnaround times and our team will issue your certificates as quickly as we possibly can.

Our highly qualified site engineers can arrive on site when needed. They will provide verbal results after the test and a written report will be sent to you within 24 working hours.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Test?

To completely fulfil Building Regulations Part E requirements, the separating walls and floors of dwellings will be tested, unless approved Robust Details are used. Sound Insulation Testing tests for both the airborne sound and the impact sound which travels through new or existing buildings . The tests cover party walls and floors between new and existing buildings, or between spaces within a new development entirely.

What is part of a Sound Insulation Test

Workers on a site will vacate the premises while the sound test is being conducted. This will facilitate an enabling and quiet environment for the tests to be carried out. Undertaking sound tests on site varies according to the size and complexity of the building project and the site conditions. If the site is simple and of regular size, it typically takes about 90 minutes to complete the sound test.

Once it is completed, the engineers will give a verbal interim result on the site and basic helpful information on what was noticed during the test, e.g. possible sound issues and future places that could cause problems.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. The sound insulation testing methodology has been outlined by Document E of the Building Regulations. The document states that every 10 units in a sub-group or group should undergo one set of test, and defines a sub-group in Section 1. Buildings to be tested are categorised into three kinds: houses, flats and rooms like care homes, student accommodation and hotel rooms. How much testing that should be done on each group is listed below:

Why is Sound Insulation Testing Relevant?

Before completing a building, all new constructions should be tested for sound insulation, as stipulated by Approved Document E since 2003. The impact sound test result should not be more than 62dB L’nTw and the airborne sound insulation should not be less than 45dB DnTw+Ctr. This Approved Document, as part of UK Building Regulations helps to ensure that new buildings are constructed to minimum standards that provide reasonable resistance to sound from other parts of the same building and from adjacent buildings. Testing for sound insulation is vital because sound influences how we live in the office, while relaxing or in the house. Restricting the sound that moves between floors and walls could result in a more relaxed and better surrounding.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. Let’s take a look at this scenario. An individual living in a block of flats might spend the weekend with friends relaxing and playing loud music. If the sound insulation on adjoining walls and floor is insufficient, the music will be distressful to neighbours, especially if they work at night. This is one way sound insulation can affect how a person lives. It can be useful in dwellings with neighbouring units/flats/rooms which have diverse purposes, by guaranteeing that an occupant in a room will hear as little noise as possible from the neighbouring room.

Do I Need a Sound Insulation Test?

Your development needs a sound insulation test if it meets one of the following criteria:

  • It’s design does not have Robust Details
  • It’s a new building with 2 or more dwellings
  • It’s being constructed to be used as a residence, like a hotel room or a hostel, or as a nursing home
  • It was once a single dwelling but is being turned into a development with several flats or units.

It is imperative that sound insulation tests be undertaken, as explained and stipulated by ADE.

Either you follow the pre-completion sound testing process stipulated therein or you use Robust Details. This way, you have conformed to the requirements. Robust details are separating elements that have been pre-tested and conform to Approved Document E sound insulation standards. When you use it, you don’t have to take a sound insulation test. However, you must abide strictly by the design from the Robust Details approved list. With sound testing, however, you’re free to pick from any design, including more cost effective and appropriate ones. This makes it a more efficient process than Robust Details. It also gives architects the opportunity to evaluate their design and give your structure a much better sound insulation which will increase sound performance.

How much does sound insulation testing cost?

To get a free quote for your dwelling, contact us. Our prices are extremely competitive and we’ve worked on developments of various sizes and types. You’re also assured of a quick turnaround time for your sound insulation test report and certificates.

Sound Insulation Test Time

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

How is Sound Insulation Testing Done?

Sound testing procedure is quite simple and our engineers are happy to explain this on site. We carry out airborne and impact tests on separating floors, and airborne tests on separating walls.

The test uses a dodecahedron speaker and pink or white noise generator for source sound. The sound source is placed in the largest room of the two. A sound level meter calculates the noise in the source room and receiver room. The meter is also used to measure the background sound, to ensure that it’s 10dB lower than the source sound, as is the standard. More background sound leads to creating a higher source sound. Airborne sound tests are conducted in this manner: two singular speaker positions are used for every source room. The noise in the receiver room is measured to determine the variations in noise level between the source and receiver room.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. The room under it is then measured for the noise levels. Calculations based on these measurements are undertaken and the results compared to the Building Regulations Part E requirements for the given type of the building. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Sound Test Equipment Used

Our high-tech sound insulation machines are UKAS calibrated and our accredited expert engineers conduct the test using Building Regulations present criteria. An airborne test calculates the amount of sound moving through a separating element. Equipment used for the test include a noise generator, speakers and sound level meter. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. The tests are administered in room with residential purposes. For example, kitchens/living spaces, lounges, bedrooms and living rooms. Test findings are compiled in a report and issued to the client. The report will be accepted by Building Control and used for signing off your project.

Sound insulation testing is essential for these dwelling types:

Sound Insulation Testing checks for both airborne and impact noise travelling through new or existing buildings. This may affect party walls and floors between new and existing buildings, or between spaces within a new development.

A structure with 2 or more units/flats

This ensures that a sound insulation system installed in residences meets the requirements of ADE.

Converting a single development to flats

When turning the single dwelling into several flats or units, the sound performance requirements of Building Regulations must be met.

Designs without Robust Details

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. Once the design does not strictly abide by the design from Robust Detail approved list, the structure will have to undergo a sound test to ensure it conforms to Building Regulations. The minimum requirements are dependent on the kind of dwelling. Permanent dwellings and rooms for residential use have different requirements.

Towns in the UK AF Acoustics Services can be Found

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Temple-Mills. Af Acoustics work with individuals, government agencies, planning and environmental consultancies, and architects. You can find our consultants all over the south east region of the country. That way we give you the most affordable quotation that will meet your budget needs.

Why AF Acoustics is the right choice for your sound insulation test

We have helped many homes and business owners in Temple-Mills with their sound tests and building’s sound performance. Our customers endorse and recommend us because of the following advantages of working with us.

Sound testing experience of over 15 years

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. In more than 15 years, we have acquired extensive experience with providing acoustic solutions to private individuals and organisations in the UK, no matter the size or scale of the project. You get expedience and value for the price.

Affordably rates

To make certain that all clients in Temple-Mills can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Temple-Mills. Contact us right now to get a quotation that’s completely free of charge.

Fast and efficient consultancy

We will interpret your problems and necessities, present you with vigorous ideas and provide acoustic advice through our extensive experience. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Adaptable test dates

Your convenience is essential to us. This is the reason we provide you with adaptable choices that allow you to pick test dates that are most advantageous for you. Contact us today to get sound testing in Temple-Mills

Next day reporting

The sooner you receive the details of your sound insulation test results, the sooner you can get your building signed or remedy any problems. We endeavour to give you the report the following working day in all situations, even when the project is complex and large in size. The conveyed report will be exhaustive, covering every issue point by point to guarantee that the best suggestions are given.

Sound Insulation Testing Services We offer

We offer a wide range of thorough acoustic solutions for our clients nationwide, and we ensure a high calibre and effective approach. To find out more about we can help you with your acoustics needs, call or email us right away.

Impact and airborne floor test

These are taken on separating floors/ceilings between residences. The measurement of the extent of noise transmitted directly through impact from one adjoining room to another is known as impact testing. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

Document E test

AF Acoustics sound testing adheres to ADE which stipulates information bearing on the sound resistance and performance of a property. The impact sound test of new dwellings should be 62dB L’nTw or less and airborne sound insulation 45dB DnTw+Ctr or more while impact results for reconstructed properties should be 64dB L’nTw and airborne sound insulation 43dB DnTw+Ctr or more.

Sound insulation test

We offer the highest levels of service and expertise and are always happy to work with you to give you the best possible chance of achieving a pass certificate. In newly completed constructions, an airborne wall test and an airborne and impact floor test will be needed to meets the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Simply contact us immediately ad you’ll get a free quotation in addition to more details about our sound testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) states the benchmarks for the acoustics of school buildings. It additionally portrays the typical methods for aligning with the Building Regulations. Are you building a new school in Temple-Mills? Contact us to arrange a sound test and make sure it meets the benchmarks of BB93.

Acoustic plan details

AF Acoustics provide detailed acoustic design services and consulting on a wide range of buildings. We have the capability and experience to develop customised solutions, and have a strong working knowledge of available proprietary acoustic products. We will develop detailed design solutions suitable for the specific demands of the project.

As anybody who has needed to handle the acoustics for a building will know, it’s essential to get proper advice, early in the project from a good acoustic expert. AF Acoustics can help you with identifying the right acoustic needs and standard for your construction at the beginning period and advise you on how to meet them.

We will help you with:

Creating acoustic detail plans for architects involved in residential construction that conform to Document E of Building Regulations, BS8233 and so on. Detail designs for the health, educational and commercial projects in order to meet up with the necessary requirements. Specifications and design details that enable good sound insulation and reduction of noise in residences. Public address and sound reinforcement for conference room, lecture theatres and so on.

Contact our professionals for a sound test quotation

As an independent acoustics consultancy, AF Acoustics is able to provide extensive acoustic survey and design, investigations in the field of planning and noise, architectural and building acoustics, and air permeability testing. Whether you are a company or a private individual, we are here to advise and guide you. If you would like a friendly and accurate sound insulation testing quote, please send an email to info@af-acoustics.com or give us a call.

020 3372 4430 Contact us

Please send the following information to us

When calling or emailing us please provide the following data

Place where the building is being built

Where is your property located in Temple-Mills?

Number of dwellings

Number of dwellings on the property

Number of floors in the building

For the right calculation of your quotation, tell us how many levels are in your building.

Configuration of dwellings (no. of units per level)

How many units are on each floor? Knowing this will help us give you an appropriate quotation.

Kind of property

Tell us the kind of property because different buildings require different amounts of tests.

New Build or conversion project

The testing requirements for new dwellings and converted properties are not the same. Tell us the type of building you have so that we give you the right quote.

Sound Insulation Testing Regulations

Get more credits for Code for Sustainable Homes and EcoHomes environmental assessment project by taking a sound insulation test which are aligned with approved document E building regulations rules.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

We have fully accredited engineers who can visit your property to issue appropriate certification that complies with the building control.

Standard division for structures (Scotland)

According to Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be performed after construction, using the procedures given in annex 5.C. of the Scottish Standards. Standard 5.1 does not apply to: fully detached houses or roofs or walkways with access solely for maintenance, or solely for the use of the residents of the dwelling below.

How to pass a sound test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. We offer design services to enable separating walls and floors with good sound insulation to meet the requirements of ADE, 2003. Whether you want some initial tests on your project, or comprehensive reports at the end, we can help you at the level that you need. The following conditions will provide you with an ample chance of passing the sound test: All windows and door have been fixed and are functioning Skirting boards are fixed are sealed Fix all light switches, light fittings and plug sockets. We work with several professionals in construction from the beginning of the design stage to the completion of the development to make certain it conforms to Document E 2003 of Building Regulations.

Certificates for test evaluation and report

To get details of the results of a completed sound insulation test, we will provide you with an analysis and report certificate. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What do the results look like?

A certificate will be issued to you whether the sound insulation treatment of the building meets the requirements of Document E of Building Regulations or not. We can provide professional advice on designs that will surpass Document E standards if the building fails the test.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed