Sound insulation testing involves the use of specialist equipment to examine how much sound is reduced off by floors and walls, of a building. It checks if a dwelling’s sound proofing treatment meets the requirements set out in Approved Document E. It is compulsory for new buildings and refurbishment projects, according to Approved Document E (ADE) updated in 2003.

Building Control does not issue completion certificates to buildings that don’t have a sound insulation certificate. Contractors and developers have sometimes discovered this, to their detriment. The significance of a sound insulation certificate cannot be overrated. Therefore, we ensure that you get the certificate speedily. We take great pride in providing our certificates to you as soon as possible after the tests.

Our highly qualified site engineers can arrive on site when needed. They will provide verbal results after the test and a written report will be sent to you within 24 working hours.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

How Sound Testing Works

To completely fulfil Building Regulations Part E requirements, the separating walls and floors of dwellings will be tested, unless approved Robust Details are used. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

What is part of a Sound Insulation Test

Workers on a site will vacate the premises while the sound test is being conducted. This will facilitate an enabling and quiet environment for the tests to be carried out. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. A dwelling or development of normal size and simplicity will more than likely be tested in 90 minutes.

After the test, the sound insulation test engineers will let you know the outcome of the test and supply simple feedback of important things noted during the test; e.g. problems that might occur in the future.

You will get a detailed written report and sound test certificate about a day after, if possible. The sound testing guidelines are stipulated in Building Regulations ADE. It requires one set of test to be conducted on 10 units in a group or sub-group. You can find out what is meant by a sub-group in Section 1 of ADE. ADE goes on to define and group the type of structures that will undergo testing. They are houses, flats and rooms that are being used or are planned to be used as residences; such as student accommodation, care homes and hotel rooms. The extent of testing required for these three groups is shown below.

Importance of Sound Insulation Testing

Before completing a building, all new constructions should be tested for sound insulation, as stipulated by Approved Document E since 2003. Results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. This is to be certain that all new developments meet a uniform minimum criterion for resistance to sound from other parts of the development and adjoining developments. Sound testing is essential due to the fact that sound impacts us wherever we are, whether it’s at home, leisure or the office. Reduced noise in the partitions and flooring of a structure leads to greater ease and a more efficient environment.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. For instance, an inhabitant in an apartment building sleeps during the day and works at night all the days of the week. If the neighbour in the upstairs flat has friends over and plays loud music, without a good sound insulation system, the working occupant will be uncomfortable and uneasy. This is just one example of how sound insulation can affect the quality of life of people in different ways. It can be useful in dwellings with neighbouring units/flats/rooms which have diverse purposes, by guaranteeing that an occupant in a room will hear as little noise as possible from the neighbouring room.

Do You Need a Sound Test?

You need a sound insulation test if you’re:

  • Constructing a nursing home or residential rooms like hostel or hotel rooms,
  • Converting a building with a single dwelling into flats,
  • Constructing a property with two or more units,
  • Using designs without Robust Details to build

Building Regulations Part E discusses sound testing in detail and has made it a requirement.

There are two ways in which to show compliance. You can either test to the regime set out in Approved Document E (ADE), or pay to use Robust Details. If you choose the latter, you must use Robust Details which are a approved design details for partitioning walls and floors. You also cannot expand or tweak the design from the Robust Detail Approved listing. However, you are exempt from the sound test. This becomes difficult when you need to pick a more appropriate or cost-effective design that will suit your needs. Sound tests enable you do that, making it more flexible. Conducting on-site pre-completion sound testing also enables the architects more scope with their design and can lead to improved sound insulation performance.

How Much Will I Pay for a Sound Insulation Test?

We can send quotation that’s completely free of charge and is based on the kind of development you have. Our prices are extremely competitive and we’ve worked on developments of various sizes and types. You’re also assured of a quick turnaround time for your sound insulation test report and certificates.

Period Sound Insulation Test Should be Carried Out

A sound test is usually conducted just before the construction is completed, and when all the doors and windows have been fixed. However, we can test your building earlier to check for problems. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

How is sound insulation testing carried out?

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. Airborne tests are conducted on party walls while impact and airborne tests are conducted on party floors.

A pink or white noise generator and a large speaker is used for the test in the biggest room between the two undergoing testing. A sound level meter calculates the noise in the source room and receiver room. The meter is also used to measure the background sound, to ensure that it’s 10dB lower than the source sound, as is the standard. More background sound leads to creating a higher source sound. For airborne sound tests, two individual speaker positions are used for each source room. Measurements are then made to determine the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

Finally, the difference in noise level is modified to accommodate reverberation time and background noise that was already in the receiver room. Reverberation time is how long it takes sound to decay by 60dB. A tapping machine is placed on the floor to execute an impact sound insulation test. The sound level in the room below it is recorded. Once the calculations are completed and the result is achieved, it is compared with Building Regulations Part E standards. Without the mathematical formulae, this explanation highlights sound insulation testing procedures in a simple manner.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Type of Sound Insulation Test Machines We Will be using

Our licensed engineers use UKAS calibrated equipment to measure sound insulation according to the present standards of Building Regulations. An airborne test is used to check how much sound is moving through the air between partitions. Equipment used for the test include a noise generator, speakers and sound level meter. A sound level meter and a tapping machine which drops metal hammers is used for impact testing. The tests are administered in room with residential purposes. For example, kitchens/living spaces, lounges, bedrooms and living rooms. The outcome of the test is written in a report and sent to the customer. This report helps Building Control sign off your building.

Sound insulation testing is essential for these dwelling types:

Sound insulation tests examine airborne and impact sound moving through buildings. It is usually undertaken between party walls and floors between buildings or between spaces within a new development.

A new building with not less than two rooms

With the sound test, you can be certain that the property has a good acoustic performance.

Converting a single development to flats

When the development is completed, ADE of Building Regulations should be checked, and sound insulation tested accordingly.

Design that don’t have Robust Details factored in

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. If the building design does not strictly adhere to Robust Details, a sound insulation test becomes necessary to meet Building Regulations. Minimum criterion differs based on the type and purpose of the development. A development with rooms intended as residences, like a hostel or hotel, won’t have the same criteria as a structure for permanent dwelling.

Towns in the UK AF Acoustics Services can be Found

AF Acoustics is an acoustic consultancy providing acoustic design services to clients nationwide, especially in Slough. Our clientele also include government agencies, architects, and organisations involved in planning and environmental consultancy. Our consultants are based in several strategic locations across the south east of the country to ensure that we can provide the most competitive quotations in the industry for sound insulation testing.

Why you should choose AF Acoustics

We have helped many homes and business owners in Slough with their sound tests and building’s sound performance. Our customers endorse and recommend us because of the following advantages of working with us.

Sound testing experience of over 15 years

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. We also have a track record of providing superior acoustic services to our customers (home and business owners) in the UK in small and large projects, giving them astounding value for their money.

Best rates available

We want to ensure that you get the best value for your money. That is why we have one of the most unbeatable rates in and outside Slough. Call us or email today to get a free quotation.

Consultancy that is effective and efficient

We offer strong durable advice based on your problem and give highly knowledgeable acoustic advice. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Test dates that are flexible

Our test date options let you pick what will suit your schedule because your comfort is essential to us. Call us now to schedule sound insulation testing in Slough

You get your report the next day

We try to provide test reports within 24 working hours. That way, you can take the right action based on the results of the test. The report will be detailed and thorough so that all necessities are written out and any advice provided.

Sound insulation services we provide

AF Acoustics offer a range of comprehensive acoustic solutions to customers nationwide, and we guarantee a high-quality and high-efficiency approach. To find out more about we can help you with your acoustics needs, call or email us right away.

Impact and airborne floor test

These are taken on separating floors/ceilings between residences. The calculation of the sound level transferred from one unit to another through a separating floor via impact is called an impact test. Impact and airborne testing is undertaken between party floors.

PART E Testing

Our sound insulation testing in accordance with Building Regulations Approved Document E, which sets out details pertaining to the resistance to the passage of sound. The impact sound test of new dwellings should be 62dB L’nTw or less and airborne sound insulation 45dB DnTw+Ctr or more while impact results for reconstructed properties should be 64dB L’nTw and airborne sound insulation 43dB DnTw+Ctr or more.

Sound test

We want to give our customers the most highest chance to acquire a pass and via our offer skilled services. To make sure a new residence meets with the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw, an airborne wall test and an airborne and impact floor test will need to be conducted. We regularly provide consultations for project managers and developers from the very start of developments, ensuring peace of mind when it comes time to having a sound test. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

For a school to meet up with Building Regulation acoustic requirements, it must adhere to Building Bulletin 93 (BB93) which explains the sound insulation expectation for schools in detail. Are you building a new school in Slough? Contact us to arrange a sound test and make sure it meets the benchmarks of BB93.

Acoustic Design

AF Acoustics give definite design services and consultancy services to all types of developments. We create bespoke solution and can provide information on the best available acoustic products. We will tailor our design solutions to your project.

When constructing a building, it’s vital you get advice from the right acoustic consultant on time. AF Acoustics uses professional expertise to discover your acoustic needs early on and proffer ideas on how to meet them.

We can assist with:

Creating acoustic detail plans for architects involved in residential construction that conform to Document E of Building Regulations, BS8233 and so on. Detail plans in commercial, educational and healthcare project for adhering to the prescribed standard. Specifications and design details that enable good sound insulation and reduction of noise in residences. Public address and sound reinforcement system

To get a sound test quote for your building, call or email our highly skilled professionals

We are an independent acoustic organisation that handles everything concerning acoustics including survey, design, architectural and building acoustics and air tightness testing. We will give you sound advice and guidance no matter who you are or the kind of project you have. To get an accurate quotation, either call us or email info@af-acoustics.com

020 3372 4430 Contact us

Please send the following information to us

In your email or during your phone call, tell us about the following

Location of property

Where in Slough is your construction?

Number of dwellings

Number of dwellings on the property

Number of levels in the structure

For an accurate calculation of the quote, tell us the number of storeys

Number of dwelling units per storey

Tell us how many units are in your structure so that we can give you the right calculation for your quotation and know the scope of the test.

Types of construction

Let us know the type of development you have so that we can undertake the required tests for it.

New dwelling or converted property

Knowing if your building is new or converted allows us to give you a competitive quotation and prepare the right test for it.

Sound Insulation Testing Regulations

We undertake sound insulation test on various buildings that adhere to Building Regulations Document E. Testing can also enable you get more credits for Code for Sustainable Homes and EcoHomes environmental assessment constructions.

Resistance to the passage of sound: Approved Document E (England and Wales)

We can have fully accredited engineers sent to your property at your convenience to provide certification for Building Regulations Part E compliance, recognised by Building Control.

Scotland Standard division for properties

Section 5.1 of the Scottish Building Standards stipulates that “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Fully detached roofs or walkways that are not used for residential purposes do not have to take the sound tests of the Scottish Standards 5.1.

How to make sure you pass your sound test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. We offer design services to enable separating walls and floors with good sound insulation to meet the requirements of ADE, 2003. The degree of guidance you require can vary, from site visits and comprehensive design reports, to simpler initial testing to know the starting point for construction. Take the following action to give your building the best opportunity to pass the sound insulation test: Inner and outer doors and windows have been installed and can be used Skirting boards are fixed Light fittings and switches and plug sockets are fitted and working. Our accomplished acoustic consultants work with developers, planners, contractors, and architects of all sizes from the early stages of the building plan to help limit any potential sound insulation performance problems to the completion of the construction, guaranteeing that all properties meet the criteria of Building Regulations Document E 2003.

Analysis and Report Certificates

After the test, AF Acoustics’ competent and well trained engineers can let you know the verbal results of your sound test and provide feedback on issues noticed during the test. We endeavour to send an investigation and report certificate the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What do the results look like?

Your test certificate will show if your development passed or failed the test and show if it adheres to the requirements of Part E of Building Regulations. We can provide professional advice on designs that will surpass Document E standards if the building fails the test.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed