Sound testing calculates the extent to which sound is blocked by the partition (walls, floors etc) of a building between dwellings. It evaluates the efficiency of the soundproofing materials that make up the structure. Part E of Building Regulations requires sound insulation in buildings and mandates that all newly completed constructions and rehabilitated developments go through sound testing.

Building Control does not issue completion certificates to buildings that don’t have a sound insulation certificate. Contractors and developers have sometimes discovered this, to their detriment. Because we understand how the sound insulation certificate affects your building project, we ensure that you get it as quickly as possible after the test. In fact, we are proud of our turnaround times and our team will issue your certificates as quickly as we possibly can.

Even before you get the certificate, you will receive the results of the test. First, our skilled and competent sound insulation test will engineers give you a verbal result at the site. Then, a written report is sent to you within 24 hours of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

How Sound Testing Works

To adhere to Building Regulations ADE requirements, adjoining walls, floors and ceilings in a building will have to be tested, except where licensed Robust Details were used. The airborne and impact sound going through new and old structures are evaluated by sound testing. This can impact adjoining walls and floors between the structures.

What is involved in Sound testing?

A sound insulation test creates a high amount of noise but needs a site with low noise levels to be taken effectively. As a result of this, workers in a testing area might have to leave the development temporarily, so that the test can be free from errors. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. Generally, a sound insulation test takes about 90 minutes for a simple, regular sized project.

The sound testing engineers then proceed to give verbal results on the site and offer helpful advice on any problem areas noticed during the duration of the test.

The entire report and individual sound test certificate will be sent to you the day after. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). ADE also states the categories of developments that should be tested. There are three: rooms, flats and houses (including bungalows) that are lived in. Examples are student accommodation, hotel rooms and care homes. Find below the testing stipulation for each kind of development.

Why is Sound Insulation Testing Relevant?

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. ADE ensures that new building are resistant to noise from adjoining buildings and other rooms within the same building. When sound resistance is high in party walls and floors, the environment is more comfortable, since sound affects every aspect of our lives – work environment, home environment and while relaxing. This is why sound testing is crucial.

Sound insulation and speech privacy are important because not having them results in an unfavourable environment for those living in the development. It would mean noise moving from one flat to another in a block of flats. If, for example, an occupant works at night and happens to hear loud music from a neighbour upstairs on a weekend night, it would be very discomforting. This is just one example of how sound insulation can affect the quality of life of people in different ways. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

How to Know if You Need Sound Insulation Testing

You need sound insulation testing if you:

  • Build a new development of 2 or more dwellings / flats
  • Convert a former single dwelling into flats
  • Build a Nursing Home or rooms for residential use, i.e. hotel or hostel
  • Have designs which do not adhere to Robust Details

ADE thoroughly explains sound testing and makes it compulsory.

All you have to do is follow the guidelines listed in the document or pay to use Robust Details and you will have fulfilled the requirements. Robust details are separating elements that have been pre-tested and conform to Approved Document E sound insulation standards. When you use it, you don’t have to take a sound insulation test. However, you must abide strictly by the design from the Robust Details approved list. Sound testing provides more flexibility by allowing different designs and is often therefore more cost effective in many ways compared to the Robust Details Scheme. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.

How Much Will I Pay for a Sound Insulation Test?

To get a free quote for your dwelling, contact us. We have tested all types and sizes of construction in the UK and issue a report and sound test certificate within 24 working hours. We offer one of the best prices. If you get a better price from another company, let us know and we will try to beat it.

Period Sound Insulation Test Should be Carried Out

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. To achieve the best results we would need the following during the test: quietness during the time of the test, 240V power supply and access to all the rooms unless a test plan has been agreed upon prior to the test time.

How a Sound Test is Done

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. Airborne tests are conducted on party walls while impact and airborne tests are conducted on party floors.

The airborne sound insulation test is carried out with a large speaker or dodecahedron speaker, using a white or pink noise generator to create the source sound, almost always in the largest room of the two rooms under testing. The noise from the source room and received by the receiver room, and background noise is measured with a sound level meter. The background noise level is also measured. The higher the background noise then the higher the source noise will need to be set, since the resulting noise level in the receiver room needs to be 10dB higher than the background noise at all measured frequencies. For airborne sound tests, two individual speaker positions are used for each source room. Measurements are then made to determine the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

The sound difference is adjusted to make an allowance for reverberation time (time in which the sound decays by 60dB) and background noise in the receiver room. Impact tests are done by placing a standardised tapping machine on the floor. The sound pressure level at the receiving room, which is below the source room, is measured. Calculations based on these measurements are undertaken and the results compared to the Building Regulations Part E requirements for the given type of the building. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Kind of Testing Equipments Used

Our high-tech sound insulation machines are UKAS calibrated and our accredited expert engineers conduct the test using Building Regulations present criteria. An airborne sound test measures levels of sound transmitted through the air through a separating element. Equipment used for the test include a noise generator, speakers and sound level meter. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. The tests are administered in room with residential purposes. For example, kitchens/living spaces, lounges, bedrooms and living rooms. Test findings are compiled in a report and issued to the client. The report will be accepted by Building Control and used for signing off your project.

These kinds of properties should undergo a sound insulation test:

Sound insulation tests examine airborne and impact sound moving through buildings. It is usually undertaken between party walls and floors between buildings or between spaces within a new development.

A new building with not less than two rooms

This makes sure that the sound insulation for the building meets all the necessary requirements.

Converting a property into several units

The development that has been converted must conform to Building Regulations sound requirements.

Design not using Robust Details

Robust Details Ltd began the Robust Details scheme in 2004. The scheme enables architects use design details for separating elements, which have been tested before to comply with Document E standards. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. Minimum criterion differs based on the type and purpose of the development. A development with rooms intended as residences, like a hostel or hotel, won’t have the same criteria as a structure for permanent dwelling.

Areas in the UK AF Acoustics Conduct Test

AF Acoustics is an acoustic consultancy providing acoustic design services to clients nationwide, especially in Fairlop. Our clients include architects, planning and environmental consultancies. We also work with government agencies and private individuals. Our consultants can be found in various places in the south east region. This way you get an affordable price.

Why you should choose AF Acoustics

Having rendered high quality service to numerous customers in Fairlop, we have gotten great positive feedback and recommendation from our clientele due to the following:

More than 15 years’ experience

With more than 15 years of experience, we have a deep knowledge of our customers’ industry and provide actionable strong advice tailored to their needs. By doing this, we have been able to continuously satisfy clients in the UK and meet their acoustic needs for over 15 years, providing great value for money.

Best rates available

To ensure all clients in Fairlop can afford superior quality sound insulation testing, we offer some of the most competitive rates you can both in and outside Fairlop. If in doubt, contact us now for a free no-obligation quote.

Fast and efficient consultancy

We will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Test dates that are flexible

Because your convenience is important to us, we provide several options to help you choose a test date that is best for you. Contact us today to get sound testing in Fairlop

Test reports arrive the next day

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. The conveyed report will be exhaustive, covering every issue point by point to guarantee that the best suggestions are given.

Sound insulation services we provide

We offer a wide range of thorough acoustic solutions for our clients nationwide, and we ensure a high calibre and effective approach. To find out more about we can help you with your acoustics needs, call or email us right away.

Impact and Airborne floor test

These are only carried out on separating floor/ceiling between dwellings. The calculation of the sound level transferred from one unit to another through a separating floor via impact is called an impact test. Airborne and Impact tests are carried out on the separating floors between habitable rooms of flats.

ADE testing

Document E of Building Regulations requires certain criteria for the sound performance of a dwelling. Our sound insulation tests are conducted in accordance to these criteria. The minimum airborne sound insulation test result should be 45dB DnTw+Ctr while the maximum impact sound test result should be 62dB L’nTw for new structures. Converted properties get a slightly different requirement. Expected minimum airborne sound insulation test result is 43dB DnTw+Ctr while expected maximum impact sound test result is 64dB L’nTw.

Sound insulation test

We offer the highest levels of service and expertise and are always happy to work with you to give you the best possible chance of achieving a pass certificate. A new dwelling may have to undergo an airborne and impact test to meet the benchmark of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We frequently give robust advice to project managers and developers from the start of the construction, ensuring that they’ll have adequate sound insulation to pass a sound test. To find out more about our sound testing services and get a free quotation, contact us now.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 testing of acoustic design in schools

Building Bulletin 93 (BB93) describes the minimum requirement for the acoustics of a school building. It also stipulates how a school can conform to Building Regulations. If building a new school in Fairlop, we can test the school to check if it meets the requirements of BB93.

Acoustic Design

AF Acoustics give definite design services and consultancy services to all types of developments. We create bespoke solution and can provide information on the best available acoustic products. We will tailor our design solutions to your project.

When constructing a building, it’s vital you get advice from the right acoustic consultant on time. AF Acoustics uses professional expertise to discover your acoustic needs early on and proffer ideas on how to meet them.

We are able to assist with:

Acoustic detail plan for architects associated with advancements on residences adhering to ADE, BS8233, etc. Detail design in educational, healthcare and commercial schemes for compliance with the relevant guidance Specifications and building services design for control of noise in noise sensitive areas. Improving sound and public address system in halls, conference rooms etc.

Contact our professionals for a sound test quotation

At AF Acoustics, we are an independent acoustic consultancy. Our work embraces acoustic surveys, acoustic design and investigation work in the fields of planning and noise, architectural and building acoustics, the monitoring and control of vibrations and air tightness testing. Our expert consultation is available to individuals and companies with all types and sizes of constructions. We will give you free quotation with highly competitive rates. Simply call us or email info@af-acoustics.com

020 3372 4430 Contact us

We will need the following information:

When contacting us for sound insulation testing quote, we will need you to provide the following information

The development’s location

Where is your property located in Fairlop?

Number of dwellings in the structure

Number of dwellings on the property

Number of levels in the structure

To get a precise quote, let us know the total number of floors you have.

Dwellings configuration per floor

To help us get you an accurate quotation and evaluate the scope of the test to be taken, tell us how many dwellings there are per floor.

Kind of structure

Knowing the kind of building is essential because it helps identify the type of test that will be conducted.

New Build or conversion project

Knowing if your building is new or converted allows us to give you a competitive quotation and prepare the right test for it.

Sounds test in accordance with building regulations

We provide sound testing and sound insulation testing on all types of buildings, for compliance with Part E Building Regulations in England and Wales and Section 5 of the Scottish Building Standards. Testing can also gain credits for Code for Sustainable Homes and EcoHomes environmental assessment schemes.

Resistance to the passage of sound: Approved Document E (England and Wales)

We can have fully accredited engineers sent to your property at your convenience to provide certification for Building Regulations Part E compliance, recognised by Building Control.

Standard division for developments (Scotland)

In the words of Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be taken at the completion of the building, using procedures given in annex 5.C. of the Scottish Standards. These standards don’t apply to detached structures that have access only for maintenance or are to used only by the occupants who live below.

How Do I Pass a Sound Insulation Test?

The best method to guarantee you pass your sound test is to design the building with a view to good sound insulation performance. This shouldn’t be exorbitant, and can save time and cost at the end, without your having to correct sound problem or pay for a re-test. If you’re not certain of how to construct your party walls and floors, to meet Document E 2003 targets, simply contact us for an efficient design service. We can study design reports, complete site visits and sound test the development to provide you with the level of assessment and consultation that your project requires from start to finish. The following conditions will provide you with an ample chance of passing the sound test: Install and make sure that all external and internal doors and windows are operational Skirting boards are fixed Light fittings and switches and plug sockets are fitted and working. We work with several professionals in construction from the beginning of the design stage to the completion of the development to make certain it conforms to Document E 2003 of Building Regulations.

Test and report certificates

To get details of the results of a completed sound insulation test, we will provide you with an analysis and report certificate. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What do the results look like?

A sound insulation certificate will be sent to you whether the property has a good sound performance in accordance with ADE or not. We can provide professional advice on designs that will surpass Document E standards if the building fails the test.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed