Sound insulation testing involves the use of specialist equipment to examine how much sound is reduced off by floors and walls, of a building. It checks if a dwelling’s sound proofing treatment meets the requirements set out in Approved Document E. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

Not doing so is a costly venture for developers and contractors as Building Control will not give a completion certificate for developments that have not undergone the test. We know how important a sound insulation certificate is to you. That is why we work hard to make certain that you get the certificate quickly. We pride ourselves on the facts that our sound insulation certificates are issued with speed and efficiency.

AF Acoustics’ competent and well-trained engineers, who will be available for testing, can even let you know the verbal results of your sound test. You will receive a written report in the space of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Does

In order to comply with Part E of the Building Regulations, developments will require the testing of separating walls and floors. The only exception is where Robust Details have been used. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

The Procedures Involved in a Sound Insulation Test

Workers on a site will vacate the premises while the sound test is being conducted. This will facilitate an enabling and quiet environment for the tests to be carried out. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. A dwelling or development of normal size and simplicity will more than likely be tested in 90 minutes.

The sound testing engineers then proceed to give verbal results on the site and offer helpful advice on any problem areas noticed during the duration of the test.

A complete report and sound insulation test certificate can be produced and issued within 24 working hours. The sound testing regime is set out in the Approved Document E of the Building Regulations. It states that one set of tests is required for every 10 units in a group or sub-group. Sub-groups are defined in Section 1 of Approved Document E (ADE). ADE goes on to define and group the type of structures that will undergo testing. They are houses, flats and rooms that are being used or are planned to be used as residences; such as student accommodation, care homes and hotel rooms. How much testing that should be done on each group is listed below:

Why is Sound Insulation Testing Relevant?

Sound insulation testing is required because ADE of Building Regulations has made it compulsory for all new buildings to take a sound test prior to finishing construction. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. These result limits were put in to create and maintain a uniform standard for sound resistance in different parts of a dwelling and between adjacent buildings. When sound resistance is high in party walls and floors, the environment is more comfortable, since sound affects every aspect of our lives – work environment, home environment and while relaxing. This is why sound testing is crucial.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. It would mean noise moving from one flat to another in a block of flats. If, for example, an occupant works at night and happens to hear loud music from a neighbour upstairs on a weekend night, it would be very discomforting. Sound insulation helps improve the quality of a person’s life in diverse ways. It can be useful in dwellings with neighbouring units/flats/rooms which have diverse purposes, by guaranteeing that an occupant in a room will hear as little noise as possible from the neighbouring room.

How to Know if You Need Sound Insulation Testing

Are you converting your property into several units? Does your design not use Robust Details? Are you constructing a new building with more than two rooms? Are you building a nursing home or rooms that will used for residential purposes, like hotels and hostels? If so, your structure needs to undergo a sound test. Document E of the Building Regulations explains sound insulation testing and makes it a necessity.

There are 2 ways you can comply. Test for sound insulation using the method of Approved Document E or use Robust Details in your development. Robust Details are design details for separating elements, which have been tested before to comply with Document E standards. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. Being able to adapt your design to suit your needs is more efficient and costs less in the long run. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.

How Much Will I Pay for a Sound Insulation Test?

We can send quotation that’s completely free of charge and is based on the kind of development you have. Not only are we highly experienced in providing sound testing services in UK, our reports and certificates get to the client within one of the fastest turnaround time and our prices are competitive. Send us a price you got that’s better than our and we will try to beat it.

Sound Insulation Test Time

The best time for a sound insulation test is just before the construction of the property is finished and after all windows and doors are fixed. However, in the case of a problem we can take the test before then. These are the things we need to conduct the test:

  • 240V power supply
  • A quiet environment
  • Access to all the units of the structure unless places to test have been decided before then.

How is Sound Insulation Testing Done?

Sound insulation testing is not complicated. Our highly qualified engineers will be willing to explain it in detail on the site. For partition walls, airborne tests are carried out. For floors there are two types, airborne and impact tests.

A big or multidirectional speaker, with a generator of pink or white noise is used to the biggest room. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. The background noise level is also measured. The higher the background noise then the higher the source noise will need to be set, since the resulting noise level in the receiver room needs to be 10dB higher than the background noise at all measured frequencies. For airborne tests, two speakers positions are used in the source room and the level of noise entering into the receiving partition room is measured. That way the difference in sound level is calculated.

This difference is modified to include background noise in the receiver room and reverberation time – time whereby a sound fades away in a closed space by 60dB. Impact tests are carried out by means of a tapping machine placed on the floor to be measured. The room under it is then measured for the noise levels. Calculations are done and the outcome is checked against ADE requirements for the type of building. Of course, this is a simple way of describing the procedure followed when a sound test is carried out, but it enables you to understand it better.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Kind of Testing Equipments Used

The testing equipment used are UKAS calibrated. Our highly qualified engineers test based on present Building Regulations conditions. The calculation of the level of noise transmitted through the air between two adjoining units is known as an airborne sound insulation test. A loudspeaker and noise generator is used in one room while a sound level meter is used in both rooms for measuring level of noise. For impact test, a tapping machine that makes impact sound by dropping metal hammers is used. A sound level meter is used to measure in the receiving room below the room the tapping machine is in. Testing can only be completed on ‘habitable’ rooms. Habitable rooms can be bedrooms, lounges, living rooms and open plan kitchen/ living spaces. Test findings are fed into a report that will be sent to the client. This report will always be acceptable to Building Control and will help you to get your development signed off.

These kinds of properties should undergo a sound insulation test:

Sound insulation tests examine airborne and impact sound moving through buildings. It is usually undertaken between party walls and floors between buildings or between spaces within a new development.

A new building with not less than two rooms

This is to ensure that the sound proofing of the building is up to standard for residential purposes.

Conversions of former single dwelling properties into flats

The development that has been converted must conform to Building Regulations sound requirements.

Design that don’t have Robust Details factored in

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. The minimum criterion is based on various factors such as the purpose of the development and if it is a permanent dwelling or rooms to be used as residences like students’ accommodations and hotels.

Parts of the UK AF Acoustics Cover

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Forest-Gate. Our clientele also include government agencies, architects, and organisations involved in planning and environmental consultancy. Our consultants can be found in various places in the south east region. This way you get an affordable price.

Why AF Acoustics is the right choice for your sound insulation test

We have helped many homes and business owners in Forest-Gate with their sound tests and building’s sound performance. Our customers endorse and recommend us because of the following advantages of working with us.

Over 15 years’ experience

We are able to offer helpful functional solutions that will solve our customer’s needs. We have over 15 years of experience satisfying the acoustic needs of UK businesses and homeowners with a proven track record on both small scale and major projects. You can always rely on us for exceptional value for money.

Competitive rates

To make certain that all clients in Forest-Gate can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Forest-Gate. Contact us right now to get a quotation that’s completely free of charge.

Prompt and productive consultancy

We will interpret your problems and necessities, present you with vigorous ideas and provide acoustic advice through our extensive experience. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Test dates that are adaptable

Because your convenience is important to us, we provide several options to help you choose a test date that is best for you. Take the first step towards your sound insulation testing in Forest-Gate by calling us now.

Next day reporting

When you get your sound test report fast, you’re able to take corrective action. We try to issue reports on the next working day no matter how large or complex the project. We make certain all relevant issues are covered and quality tips are supplied by detailing all the aspects of the test in the report.

The sound testing services we provide

AF Acoustics provide a scope of exhaustive and detailed acoustic solutions for clients across the country, making certain our techniques have the best quality and performance. Call or mail us today so we can provide you with more knowledge on your acoustics needs.

Airborne and impact tests for floors/ceilings

These are performed on floors and/or ceilings between units. An impact test measures the levels of noise transmitted directly through a separating construction. These floors in habitable rooms of flats undergo both impact and airborne tests.

ADE testing

Our sound insulation testing in accordance with Building Regulations Approved Document E, which sets out details pertaining to the resistance to the passage of sound. The impact sound test of new dwellings should be 62dB L’nTw or less and airborne sound insulation 45dB DnTw+Ctr or more while impact results for reconstructed properties should be 64dB L’nTw and airborne sound insulation 43dB DnTw+Ctr or more.

Sound insulation test

With our professional and highly skilled expertise, we are willing to work with our clients to help them get a pass certificate in every situation. In newly completed constructions, an airborne wall test and an airborne and impact floor test will be needed to meets the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) explains the sound performance requirement for the acoustics of school buildings. It likewise states how a school can meet this requirement. If building a new school in Forest-Gate, we can test the school to check if it meets the requirements of BB93.

Acoustic design details

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

Getting advice on the acoustics of a development as early as possible is crucial. AF Acoustics can enable you to do that by advising you on the appropriate acoustic requirements of your property very early in the building process and recommending what to do to fulfil them.

We can assist with:

Creating acoustic detail plans for architects involved in residential construction that conform to Document E of Building Regulations, BS8233 and so on. Detail layout for the commercial, health and educational constructions in order to align with regulations. Specifications and building services design for control of noise in noise sensitive areas. Public address and sound reinforcement for conference room, lecture theatres and so on.

Contact AF Acoustics specialist for sound insulation test quotes

At AF Acoustics, we are an independent acoustic consultancy. Our work embraces acoustic surveys, acoustic design and investigation work in the fields of planning and noise, architectural and building acoustics, the monitoring and control of vibrations and air tightness testing. Whether you are a company or a private individual, we are here to advise and guide you. If you would like a friendly and accurate sound insulation testing quote, please send an email to info@af-acoustics.com or give us a call.

020 3372 4430 Contact us

Giving the following information to us will be helpful

When contacting us, please give us the following information

Location of property

Provide the location of your building in Forest-Gate.

Number of dwellings in the structure

Number of dwellings on the property

How many storeys are there?

For an accurate calculation of the quote, tell us the number of storeys

Configuration of dwellings (no. of units per level)

Tell us how many units are in your structure so that we can give you the right calculation for your quotation and know the scope of the test.

Kind of structure

The type of building, as different building types typically require a different testing.

New dwelling or converted property

The testing requirements for new dwellings and converted properties are not the same. Tell us the type of building you have so that we give you the right quote.

Building regulations for sound insulation test

Our ADE compliant sound tests can help you gain credits for Code for Sustainable Homes and EcoHomes environmental assessment structures.

Building regulations document E resistance to the passage of sound (England and Wales)

We can have fully accredited engineers sent to your property at your convenience to provide certification for Building Regulations Part E compliance, recognised by Building Control.

Scotland Standard division for completed constructions

In the words of Section 5.1 of the Scottish Building Standards, “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests should be taken at the completion of the building, using procedures given in annex 5.C. of the Scottish Standards. These standards don’t apply to detached structures that have access only for maintenance or are to used only by the occupants who live below.

Passing a sound insulation test

Make sure you pass your sound test by having efficient sound insulation included in the building design. It saves time and money and helps you avoid repair work and re-test expenses. We offer design services that help you construct separating walls and floors with good sound performance that meet ADE demands. Our consultation process is led by your project requirements and may include assessment of design reports, test of the development and multiple site visits. The following conditions will provide you with an ample chance of passing the sound test: All windows and doors have been fitted and work Skirting boards are fitted and sealed Light switches, plug sockets, and light fittings are adequately fixed. Our experienced acoustic consultants work with developers, contractors, architects and planners of all sizes from the early design stage to help minimise any potential issues right through to project completion, ensuring that all properties are compliant with Building Regulations Document E 2003.

Analysis and Report Certificates

After the test, AF Acoustics’ competent and well trained engineers can let you know the verbal results of your sound test and provide feedback on issues noticed during the test. We endeavour to send an investigation and report certificate the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

What the results look like

You will get your sound insulation test certificate whether you pass or fail the sound tests. In the event of a wall or floor not achieving the Part E requirements, it may be necessary to carry out remedial works before having another sound test carried out. We can provide you with remedial design advice to help you achieve the Building Regulations requirements.


Sound Insulation FAQ’s

[ultimate-faqs include_category=”sound-insulation”]

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed