Sound insulation testing involves the use of specialist equipment to examine how much sound is reduced off by floors and walls, of a building. It checks if a dwelling’s sound proofing treatment meets the requirements set out in Approved Document E. Part E of Building Regulations requires sound insulation in buildings and mandates that all newly completed constructions and rehabilitated developments go through sound testing.

Not having a sound insulation certificate issued after a test, has resulted in additional costs and expenses for developers. Any development that has not taken a sound test will not be given a completion certificate by Building Control. As a result of this, we try to ensure that you are issued with a sound insulation certificate as fast as possible. We pride ourselves on the facts that our sound insulation certificates are issued with speed and efficiency.

Our highly qualified site engineers can arrive on site when needed. They will provide verbal results after the test and a written report will be sent to you within 24 working hours.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What is a Sound Insulation Test?

In order to comply with Part E of the Building Regulations, developments will require the testing of separating walls and floors. The only exception is where Robust Details have been used. Sound testing conducts impact and airborne sound test on structures. The tests include the separating floors, walls and areas between buildings within developments.

What is involved in Sound Insulation Testing

The sound test itself produces very high levels of noise but also requires relatively quiet conditions on site. For these reasons, any workforce in the testing area will have to leave temporarily to ensure test accuracy. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. A structure that is simple and the conventional size will usually take 90 minutes to be tested.

Once this is done, the sound test engineers give temporary results while they’re still on the site. They will also provide suggested solutions to possible problem areas noted during testing.

The entire report and individual sound test certificate will be sent to you the day after. The sound testing guidelines are stipulated in Building Regulations ADE. It requires one set of test to be conducted on 10 units in a group or sub-group. You can find out what is meant by a sub-group in Section 1 of ADE. Buildings are divided into three kinds for the test – houses, flats and rooms built for or converted to residential dwellings, like student accommodation, care homes and hotel rooms. The volume of testing carried out on each group is written below.

Importance of Sound Insulation Testing

Document E of Building regulations, from 2003, made it compulsory for all new UK constructions to undertake a pre-completion sound test. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. The aim of Approved Documet E of the Building Regulations is to establish a minimum standard for the reduction in noise levels between all dwellings in a new or refurbished building. Sound affects our life no matter where we are, at home, work or while relaxing. Places with lowered noise are more comfortable and enabling. Sound testing ensures that noise reduction in a building is effective.

There are so many more reasons why sound insulation and speech privacy are vital. An inefficient sound insulation treatment will lead to uneasiness for the inhabitants of the dwelling. It would mean noise moving from one flat to another in a block of flats. If, for example, an occupant works at night and happens to hear loud music from a neighbour upstairs on a weekend night, it would be very discomforting. Sound insulation helps improve the quality of a person’s life in diverse ways. Then there are developments where each neighbouring room / flat / unit has mixed uses. If the development has passed the sound insulation test, noise is reduced to a minimum.

Does Your Development Need a Sound Insulation Test?

Are you converting your property into several units? Does your design not use Robust Details? Are you constructing a new building with more than two rooms? Are you building a nursing home or rooms that will used for residential purposes, like hotels and hostels? If so, your structure needs to undergo a sound test. Sound insulation is covered and made mandatory under Approved Document E of The Building Regulations.

There are two ways in which to show compliance. You can either test to the regime set out in Approved Document E (ADE), or pay to use Robust Details. Robust Details are a set of specific design details for walls and floors that have been previously tested to show compliance and must be used if this route is selected. With it, you don’t need a sound insulation test, but you must completely follow every aspect of the design from the Robust Detail Approved list. Sound testing provides more flexibility by allowing different designs and is often therefore more cost effective in many ways compared to the Robust Details Scheme. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.

Cost of Sound Insulation Testing

To get a free quote for your dwelling, contact us. We have worked throughout the country on all sizes of project, and should a sound insulation report and certificates be required, we can provide the fastest turnaround times and most competitive prices available. If you get a better quote elsewhere, simply forward it to us and we will try and beat it!

Sound Insulation Test Time

We can undertake your sound tests when your building has almost been completed. By this time, you should have fixed internal and external doors and windows. We can conduct sound tests beforehand if required. For your sound tests to be conducted successfully we need the property to be quiet, with workers not near the rooms to be tested during the test time (a noisy environment makes the test difficult and sometimes unsuccessful). We also need access to all units unless the test program has been compiled earlier. Finally, we need 240V power supply.

The Process of a Sound Test

The procedures of a sound insulation test are not difficult. Our site engineers can help you understand it better during the testing time. For partition walls, airborne tests are carried out. For floors there are two types, airborne and impact tests.

A big or multidirectional speaker, with a generator of pink or white noise is used to the biggest room. The noise from the source room and received by the receiver room, and background noise is measured with a sound level meter. The background noise level is also measured. The higher the background noise then the higher the source noise will need to be set, since the resulting noise level in the receiver room needs to be 10dB higher than the background noise at all measured frequencies. Airborne sound tests are conducted in this manner: two singular speaker positions are used for every source room. The noise in the receiver room is measured to determine the variations in noise level between the source and receiver room.

Finally, the difference in noise level is modified to accommodate reverberation time and background noise that was already in the receiver room. Reverberation time is how long it takes sound to decay by 60dB. Impact tests are conducted by fixing a tapping machine on the floor. The room under it is then measured for the noise levels. This is used in calculating and computing the results. These results are checked against Building Regulations ADE conditions for that kind of dwelling. This is of course, a somewhat simplified explanation without the various mathematical formulae involved, but helps to explain the process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Insulation Testing Equipment do we use?

Our high-tech sound insulation machines are UKAS calibrated and our accredited expert engineers conduct the test using Building Regulations present criteria. An airborne test is used to check how much sound is moving through the air between partitions. We use pink or white noise generator and speakers on one side of the partition. A sound level meter is used on calculating sound in both units. We use a tapping machine, which drops metal hammers onto the floor to create impact noise. We then measure the amount of sound that passes through the partition with a sound level meter in the room under the tapping machine. Testing can only be completed on ‘habitable’ rooms. Habitable rooms can be bedrooms, lounges, living rooms and open plan kitchen/ living spaces. You will get the test results in a report within a working day. This report can be used to help sign off your building as it is accepted by Building Control.

Sound Insulation Testing is necessary for these types of builds:

Sound Insulation Testing checks for both airborne and impact noise travelling through new or existing buildings. This may affect party walls and floors between new and existing buildings, or between spaces within a new development.

Property with two or more units

This makes sure that the sound insulation for the building meets all the necessary requirements.

Redevelopment of a building with a single dwelling into flats

When turning the single dwelling into several flats or units, the sound performance requirements of Building Regulations must be met.

Design that don’t have Robust Details factored in

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the building design is not in line with any Robust Details, it will require sound testing to ensure its compliance with the buildings regulations. A building built as a permanent dwelling has different minimum standards from a building with rooms built for residential purpose, like a hotel or a hostel.

Areas in the UK AF Acoustics Conduct Test

AF Acoustics is an acoustics design services and consultancy company. Our clients can be found nationwide, especially in Hainault. Our clients include architects, planning and environmental consultancies. We also work with government agencies and private individuals. You can find our consultants all over the south east region of the country. That way we give you the most affordable quotation that will meet your budget needs.

Why you should pick AF Acoustics for your sound testing

Our sound testing experts and engineers have worked with various homes and businesses in Hainault. Our clients refer us to others because of the following benefits of working with us.

Sound testing experience of over 15 years

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. Our clients in the UK are completely satisfied with our acoustic solutions. Irrespective of the type of project you have, minor or major, you can be assured that we’ll give outstanding value for your money.

Affordably rates

Compared to other sound insulation testing service in Hainault, our prices are extremely competitive. This is because we want you to be able to afford the best expert sound testing service there is. To get a free quote for your dwelling, contact us today.

Prompt and productive consultancy

Our expert acoustic advice is tailored to your specific needs based on our experience which enable us to provide strong solutions. When you contact us for expert direction, we make it our utmost priority and convey exact answers quickly. We suggest compelling solutions that are in accordance with your present and long-term needs.

Test dates that are flexible

We make your convenience our priority. Therefore, we offer flexible alternatives that can help you select test dates that suit you itinerary. Take the first step towards your sound insulation testing in Hainault by calling us now.

Test reports arrive the next day

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. That way, you can take immediate action on the recommendations given. Our reports are thorough and cover all the important issues.

Sound insulation testing services AF Acoustics undertake

We offer a wide range of thorough acoustic solutions for our clients nationwide, and we ensure a high calibre and effective approach. To find out more about we can help you with your acoustics needs, call or email us right away.

Impact and airborne tests for floors

These are taken on separating floors/ceilings between residences. Impact testing evaluates how much the sound flowing from one partition to another through party floors via impact is. These floors in habitable rooms of flats undergo both impact and airborne tests.

ADE testing

Our sound insulation tests meet the requirements of Building Regulations Part E, which describes building structures resistance to the movement of sound within and from adjoining structures. 62dB L’nTw or less impact sound and 45dB DnTw+Ctr or higher airborne sound insulation is the required result for newly completed constructions. On the other hand, 64dB L’nTw or less impact sound and 43dB DnTw+Ctr or higher airborne sound insulation is expected from refurbished buildings.

Sound Insulation Testing

We offer the highest amount of aptitude and high quality service, and are constantly ready to work with our clients to give the most ideal chance of accomplishing a pass certificate. To make sure a new residence meets with the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw, an airborne wall test and an airborne and impact floor test will need to be conducted. We routinely give advice to developers and project managers from the beginning of the project, guaranteeing certainty when the time for a sound test is at hand. Simply contact us immediately ad you’ll get a free quotation in addition to more details about our sound testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

BB93 Acoustic Design testing in Schools

Building Bulletin 93 (BB93) explains the sound performance requirement for the acoustics of school buildings. It likewise states how a school can meet this requirement. Are you building a new school in Hainault? Contact us to arrange a sound test and make sure it meets the benchmarks of BB93.

Acoustic plan

AF Acoustics provide detailed acoustic design services and consulting on a wide range of buildings. We have the capability and experience to develop customised solutions, and have a strong working knowledge of available proprietary acoustic products. We will develop detailed design solutions suitable for the specific demands of the project.

Getting advice on the acoustics of a development as early as possible is crucial. AF Acoustics can enable you to do that by advising you on the appropriate acoustic requirements of your property very early in the building process and recommending what to do to fulfil them.

We are able to assist with:

Acoustic detail design for architects engaged with residential improvements in consistence with Part E Building Regulations, BS8233 and so on. Detail designs for the health, educational and commercial projects in order to meet up with the necessary requirements. Specification and design of building services for noise control in residential and other noise sensitive scenarios Public address and sound reinforcement system

Call Our Experts Now For A Sound Insulation Testing Quote

Our services at AF Acoustics include acoustic design and investigation, evaluation and calculation of noise, acoustic survey, building an architectural acoustics and air pressure testing. Our expert consultation is available to individuals and companies with all types and sizes of constructions. We will give you free quotation with highly competitive rates. Simply call us or email info@af-acoustics.com

020 3372 4430 Contact us

We will need the following information:

When contacting us for sound insulation testing quote, we will need you to provide the following information

Location of development

Where in Hainault the property is situated

Number of dwellings

Total number of dwellings in the structure

How many storeys are there?

For the right calculation of your quotation, tell us how many levels are in your building.

Configuration of dwellings (no. of units per level)

To help us get you an accurate quotation and evaluate the scope of the test to be taken, tell us how many dwellings there are per floor.

Types of construction

Tell us the kind of property because different buildings require different amounts of tests.

Newly completed construction or conversion

The testing requirements for new dwellings and converted properties are not the same. Tell us the type of building you have so that we give you the right quote.

Building regulations for sound test

We undertake sound insulation test on various buildings that adhere to Building Regulations Document E. Testing can also enable you get more credits for Code for Sustainable Homes and EcoHomes environmental assessment constructions.

Resistance to the passage of sound: Approved Document E (England and Wales)

We have fully accredited engineers who can visit your property to issue appropriate certification that complies with the building control.

Standard division for structures (Scotland)

Section 5.1 of the Scottish Building Standards stipulates that “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Tests, which are conducted after building utilizing the methodology given in annex 5.C. of the Scottish Standard 5.1 does not apply to: completely disconnected houses, rooftops and walkways with access exclusively for the use of the occupants of the home underneath.

How to make sure you pass your sound test

The best method to guarantee you pass your sound test is to design the building with a view to good sound insulation performance. This shouldn’t be exorbitant, and can save time and cost at the end, without your having to correct sound problem or pay for a re-test. We offer design services to enable separating walls and floors with good sound insulation to meet the requirements of ADE, 2003. The degree of guidance you require can vary, from site visits and comprehensive design reports, to simpler initial testing to know the starting point for construction. The following criteria should be followed to provide you with the best chance of passing your sound test: Windows and internal and external doors are fitted and operable Fit and seal skirting boards Light switches, plug sockets, and light fittings are adequately fixed. Our expert acoustic consultants work with planners, developers, architects and contractors from the beginning of the design stage till when the property is finished to ensure it meets the conditions of Document E 2003.

Analysis and Report Certificates

We try to issue a certificate to give you the details of the test evaluation and report, by the next day. After the test, our site engineers will provide verbal results and advise you on how to solve potential problem or future areas of concern. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The way the results look

A sound insulation certificate will be sent to you whether the property has a good sound performance in accordance with ADE or not. If a partition wall or floor does not comply with Part E standards, repair work and another sound test will be needed. We can give robust advice on that to ensure you pass.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed
  • Sunday Closed