Sound testing rates the amount of sound the soundproofing insulation installed in a building for reduction of sound. It checks the amount of sound transmitted and the amount reduced by the building’s partitions. It has been a mandatory part of the Building Regulations for new build and refurbishment projects since Approved Document E (ADE) was revised in 2003.

At the completion of the test, a sound insulation certificate is issued. Without the certificate, Building Control will not release the building completion certificate to the contractors and developers of the project. The significance of a sound insulation certificate cannot be overrated. Therefore, we ensure that you get the certificate speedily. In fact, we are proud of our turnaround times and our team will issue your certificates as quickly as we possibly can.

Even before you get the certificate, you will receive the results of the test. First, our skilled and competent sound insulation test will engineers give you a verbal result at the site. Then, a written report is sent to you within 24 hours of a working day.

Our Guarantee

  • Over 15 years experience
  • State of the art equiptment
  • Onsite Support
  • Next Day Report Turn Around
Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

What Sound Testing Does

To adhere to Building Regulations ADE requirements, adjoining walls, floors and ceilings in a building will have to be tested, except where licensed Robust Details were used. The airborne and impact sound going through new and old structures are evaluated by sound testing. This can impact adjoining walls and floors between the structures.

What is involved in Sound Insulation Testing

A sound insulation test creates a high amount of noise but needs a site with low noise levels to be taken effectively. As a result of this, workers in a testing area might have to leave the development temporarily, so that the test can be free from errors. A sound insulation test on a project is taken according to the scale and complexity of the construction and the conditions of the site. Generally, a sound insulation test takes about 90 minutes for a simple, regular sized project.

The sound testing engineers then proceed to give verbal results on the site and offer helpful advice on any problem areas noticed during the duration of the test.

A full report and individual sound test certificates can be generated and sent out the next day. The way a sound test is conducted is determined by ADE of Building Regulations. It mandates that in all developments, every 10 units in a group or sub-group will undertake one set of tests. It explicitly states what a sub-group is in Section 1. There are three types of grouping criteria that need to be assessed: dwelling houses (including bungalows), flats and rooms for residential purposes, such as student accommodation and hotel rooms, care homes etc. Find below the testing stipulation for each kind of development.

Importance of Sound Insulation Testing

Sound insulation testing is required because ADE of Building Regulations has made it compulsory for all new buildings to take a sound test prior to finishing construction. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. This Approved Document, as part of UK Building Regulations helps to ensure that new buildings are constructed to minimum standards that provide reasonable resistance to sound from other parts of the same building and from adjacent buildings. Sound insulation testing is important because sound affects the way we live, whether at work, in the home or whilst at leisure. Noise reduction between walls and floors could result in a more comfortable, productive environment.

Insufficient sound insulation causes distress and comfort while an effective sound insulation system brings about speech privacy. This is one of the several reasons why sound insulation is a key element in building. It would mean noise moving from one flat to another in a block of flats. If, for example, an occupant works at night and happens to hear loud music from a neighbour upstairs on a weekend night, it would be very discomforting. Sound insulation helps improve the quality of a person’s life in diverse ways. There are also developments where the neighbouring units are used for different purposes. In such cases, a sound test ensures that the noise coming from each unit is minimal.

Do I Need a Sound Insulation Test?

Are you converting your property into several units? Does your design not use Robust Details? Are you constructing a new building with more than two rooms? Are you building a nursing home or rooms that will used for residential purposes, like hotels and hostels? If so, your structure needs to undergo a sound test. It is imperative that sound insulation tests be undertaken, as explained and stipulated by ADE.

All you have to do is follow the guidelines listed in the document or pay to use Robust Details and you will have fulfilled the requirements. Robust details are separating elements that have been pre-tested and conform to Approved Document E sound insulation standards. Using Robust Details, without taking a test, limits you to the design you’ve picked. This becomes difficult when you need to pick a more appropriate or cost-effective design that will suit your needs. Sound tests enable you do that, making it more flexible. When on-site pre–completion building sound tests are taken, architects have more scope with their design and can increase the sound insulation performance of the construction.

Cost of Sound Testing

To get a free quote for your dwelling, contact us. Our prices are extremely competitive and we’ve worked on developments of various sizes and types. You’re also assured of a quick turnaround time for your sound insulation test report and certificates.

Sound Insulation Test Time

The ideal period for a sound insulation test is after the fitting of windows and doors, and before the building is finished. If you want, AF Acoustics can conduct tests before then to find out if there are any problems on your property. These are the things we need to conduct the test:

  • 240V power supply
  • A quiet environment
  • Access to all the units of the structure unless places to test have been decided before then.

The Process of a Sound Test

Our sound test engineers can answer your questions and make the sound test process easy to understand on site, during the time of the test. Airborne tests are conducted on party walls while impact and airborne tests are conducted on party floors.

The test uses a dodecahedron speaker and pink or white noise generator for source sound. The sound source is placed in the largest room of the two. The sound in the source room and receiver room (sharing a separating wall with the source room) is measured with a sound level meter. Noise in the background is also calculated. More noise in the background means a higher level of source sound will be created since it’s supposed to be 10dB higher than background noise on all calculated frequencies. For airborne sound tests, two individual speaker positions are used for each source room. Measurements are then made to determine the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

Finally, the difference in noise level is modified to accommodate reverberation time and background noise that was already in the receiver room. Reverberation time is how long it takes sound to decay by 60dB. Impact sound tests are performed with a tapping machine positioned on the floor of the source room. Noise level in the room below is measured at various different frequencies. This is used in calculating and computing the results. These results are checked against Building Regulations ADE conditions for that kind of dwelling. Without the mathematical formulae used in the calculations, this is a simple explanation, however, it helps explain the testing process.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Kind of Testing Equipments Used

You can expect UKAS calibrated equipment from us, as stipulated by Building Regulations. Our certified engineers conduct tests to meet the current guidelines. An airborne test is used to check how much sound is moving through the air between partitions. We use a loudspeaker and noise generator that produces white or pink noise on one side of the partition, and measure with a sound level meter on both sides to calculate the sound insulation performance of the partition. For impact sound testing, the equipment used is a tapping machine that uses dropping hammers to create noise and a sound level meter. Sound insulation tests are conducted in liveable rooms like the sitting room, lounges, kitchen/living spaces and bedrooms. You will get the test results in a report within a working day. This report can be used to help sign off your building as it is accepted by Building Control.

Sound insulation testing is essential for these dwelling types:

The airborne and impact sound going through new and old buildings are evaluated by sound testing. This can impact adjoining walls and floors between the building.

Two or more new build dwellings or flats

This makes certain that the dwellings have adequate sound proofing.

Converting a single development to flats

The development that has been converted must conform to Building Regulations sound requirements.

Designed in a way that does not adhere to Robust Details

Robust Detail Ltd set up the Robust Detail Scheme in 2004 to make sure architect and building designs construct partition walls and floors that comply with Approved Document E sound insulation standards. If the design does not completely follow Robust Details, sound insulation testing will occur to be certain the building meets ADE criteria. Minimum criterion differs based on the type and purpose of the development. A development with rooms intended as residences, like a hostel or hotel, won’t have the same criteria as a structure for permanent dwelling.

Which areas of the UK does AF Acoustics cover?

AF Acoustics provides acoustic design services to customer nationwide, especially in Manor-House. Our clients include architects, planning and environmental consultancies. We also work with government agencies and private individuals. Our consultants can be found in various places in the south east region. This way you get an affordable price.

Why AF Acoustics is the right choice for your sound insulation test

Our sound testing experts and engineers have worked with various homes and businesses in Manor-House. Our clients refer us to others because of the following benefits of working with us.

15 years’ experience

Our experience of over 15 years has enabled us understand our clients need and industry extensively. As a result, our advice is applicative, serviceable and will meet the client at the point of their needs. By doing this, we have been able to continuously satisfy clients in the UK and meet their acoustic needs for over 15 years, providing great value for money.

Great prices

To make certain that all clients in Manor-House can pay for excellent sound insulation testing services, we have one of the best and most competitive prices found in and around Manor-House. Contact us right now to get a quotation that’s completely free of charge.

Fast and efficient consultancy

We will listen to your wishes, provide you sturdy solutions and deliver acoustic consultancy through our expertise. Both your short and long-term needs are handled with our professional guidance and quick answers to your problems.

Test dates that are adaptable

Our test date options let you pick what will suit your schedule because your comfort is essential to us. Call us now to schedule sound insulation testing in Manor-House

Get your test reports quickly

Getting your report quickly ensures you can take immediate action. We work towards issuing test reports within the next working day, despite the size or complexity of the construction. The delivered report will be comprehensive and well detailed to ensure all relevant issues are covered and any recommendations are provided.

The sound testing services we provide

With AF Acoustics, you get a highly effective and expert acoustic advice which our customers all over UK have benefited from. Call or mail us today so we can provide you with more knowledge on your acoustics needs.

Impact and airborne tests for floors

The ceilings/floors of developments undergo impact and airborne floor testing. Impact testing evaluates how much the sound flowing from one partition to another through party floors via impact is. Airborne and impact tests are conducted on the floor partitions between liveable rooms.

Document E test

Our sound tests align to Part E of Building Regulations guideline, which thoroughly describes sound resistance level and performance from structures. For new buildings, results for impact sound should be 62dB L’nTw or less while those for airborne sound insulation should be 45dB DnTw+Ctr or more. Converted structures expected impact sound results increases by 2dB L’nTw while the airborne sound results reduces by 2dB DnTw+Ctr.

Sound test

With our professional and highly skilled expertise, we are willing to work with our clients to help them get a pass certificate in every situation. In newly completed constructions, an airborne wall test and an airborne and impact floor test will be needed to meets the standards of greater than 45dB DnTw+Ctr and less than 62dB L’nTw. We regularly offer consultations to builders and project managers at the beginning of the development, so that they can take the appropriate action and are confident when it’s time to take the sound insulation test. Phone or email us for a free quote and more information on our sound insulation testing services.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com

Acoustic design testing in schools in line with BB93

For a school to meet up with Building Regulation acoustic requirements, it must adhere to Building Bulletin 93 (BB93) which explains the sound insulation expectation for schools in detail. Are you building a new school in Manor-House? Contact us to arrange a sound test and make sure it meets the benchmarks of BB93.

Acoustic design details

We have provided acoustic design services and consulting to various clients with different types and sizes of dwellings. We also give customised solutions and have a deep understanding of acoustic merchandise. Due to this fact, we will provide precise design answers suitable for the specific needs of the construction.

It is critical to get right professional assistance ahead of schedule from a highly qualified acoustic specialist. AF Acoustics can assist you with identifying the right acoustic propertiesfor your project at very early on in the construction process and tell you the best way to get them, utilizing a deep know-how of acoustic design.

We are able to assist with:

Acoustic detail layout for architect developing structures complying to Building regulations, BS8233 and so on. Detail designs for the health, educational and commercial projects in order to meet up with the necessary requirements. Specifications and building services design for control of noise in noise sensitive areas. Public address and sound reinforcement for conference room, lecture theatres and so on.

Contact our professionals for a sound test quotation

We are an independent acoustic organisation that handles everything concerning acoustics including survey, design, architectural and building acoustics and air tightness testing. Our expert consultation is available to individuals and companies with all types and sizes of constructions. We will give you free quotation with highly competitive rates. Simply call us or email info@af-acoustics.com

020 3372 4430 Contact us

Please send the following information to us

When contacting us for sound insulation testing quote, we will need you to provide the following information

Construction’s location

Where is your development situated in Manor-House

Number of dwellings in the building

What is the number of units in the development?

Number of levels in the structure

Let us know the number of floors in your development so that we can give you an accurate quotation.

Configuration of dwellings (no. of units per level)

To help us get you an accurate quotation and evaluate the scope of the test to be taken, tell us how many dwellings there are per floor.

Building type

Knowing the kind of building is essential because it helps identify the type of test that will be conducted.

Newly completed construction or conversion

Knowing if your building is new or converted allows us to give you a competitive quotation and prepare the right test for it.

Building regulations for sound insulation test

Our ADE compliant sound tests can help you gain credits for Code for Sustainable Homes and EcoHomes environmental assessment structures.

Sound resistance and performance: Document E of Building Regulations (England and Wales)

We have fully accredited engineers who can visit your property to issue appropriate certification that complies with the building control.

Scotland Standard division for properties

Section 5.1 of the Scottish Building Standards states “Every building must be designed and constructed in such a way that each wall and floor separating one dwelling from another, or one dwelling from another part of the building, or one dwelling from a building other than a dwelling, will limit the transmission of noise to the dwelling to a level that will not threaten the health of the occupants or inconvenience them in the course of normal domestic activities.” Fully detached roofs or walkways that are not used for residential purposes do not have to take the sound tests of the Scottish Standards 5.1.

How to make sure you pass your sound test

All you have to do to pass your sound test is include adequate sound insulation in the design. That way, you save time and cost for repair work and re-test. We offer design services that help you construct separating walls and floors with good sound performance that meet ADE demands. Whether you want some initial tests on your project, or comprehensive reports at the end, we can help you at the level that you need. The following conditions will provide you with an ample chance of passing the sound test: Windows and internal and external doors are fitted and operable Skirting boards are fixed are sealed Plug sockets, light switches and fittings are in place and working. Our accomplished acoustic consultants work with developers, planners, contractors, and architects of all sizes from the early stages of the building plan to help limit any potential sound insulation performance problems to the completion of the construction, guaranteeing that all properties meet the criteria of Building Regulations Document E 2003.

Test and report certificates

After the sound insulation test, the sound testing engineer will provide provisional results whilst on-site, as well as providing basic feedback about what has been noted during the test, e.g. potential problems or any future areas of concern. A full report and individual sound test certificates can be generated and sent out usually the next working day. 6. Even before you get the certificate, you get the verbal results of the test. First, our completely skilled and competent sound insulation test engineers give you a verbal result at the site. They also offer advice on potential problems. Then the test report certificate is sent to you within 24 working hours, when feasible.

The results

A sound insulation certificate will be issued whether the Sound Testing results and report indicate compliance with Part E of the Building Regulations or not. If a partition wall or floor does not comply with Part E standards, repair work and another sound test will be needed. We can give robust advice on that to ensure you pass.


Sound Insulation FAQ’s

The minimum requirements depend on a variety of factors such as if the development is a new build or refurbished, whether the development is intended to be a permanent dwelling, or classified as “rooms of residential purposes” (e.g. hotels, student accommodation, etc).

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation. Engaging our services at an early stage allows us to check designs and add necessary measures to prevent this occurring after construction. In the worst cases, flanking can exceed the direct transmission and lead to a failed test, despite highly specified partitions.

In the case of impact sound, the building construction is caused to vibrate as a result of a physical impact, such as footsteps on floors or stairs. The resulting vibration is radiated into other rooms in the building.

We can provide preliminary results on the day of test. We strive to deliver next day reporting in all scenarios regardless the complexity or size of the project. The delivered report will be comprehensive and detailed, to ensure all relevant issues are covered. The best recommendations can also be sent in a separate report or email.

We can normally conduct up to a maximum of three sets of tests per day. One set is two airborne floor tests, two airborne wall tests and two impact floor sound tests.

When it comes to the acoustic tests, a full set of tests should take approximately 90 minutes.

The requirements of sound insulation testing are fully detailed in the Building Regulations Approved Document, available here [link], under Part E (2003).

This requires all residential buildings to be tested when they involve walls and/or floors. These are known as party elements.

Assuming no tests are failed, building control bodies should stipulate at least one set of tests for every ten dwelling-houses, flats or rooms for residential purposes in a group or sub-group.

New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound insulation of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound insulation of no less than 43dB DnTw+Ctr.

We recommend that if possible, we are contacted before a build to provide a design review and advice on how to meet quality standards.

Should the test fail, we can offer advice on how to improve the sound insulation. We have consulted on hundreds of building projects in the past, and have ensured all of them have met the building regulations. If a sound insulation test fails, we can give remindial advice to ensure the tests passes later.

We understand that most clients would prefer testing to take place as soon as possible. Once you get in touch we will schedule the test at the earliest available opportunity.

You can call us today to set up an appointment for sound insulation testing. Our scheduling is flexible so that you can get the service you need at your convenience.

Ideally, a test should be carried out as early as possible as problems are more difficult to fix the further along you are. Where possible, it’s recommended that testing is carried out before kitchens or bathrooms are installed. The minimum that we require to be able to carry out a test is:

  • All doors, windows and seals should be fully fitted and closable
  • All electrical fittings should be fitted and working
  • 240V mains power must be available on-site in all rooms
  • Gaps in walls and floors should be fully sealed
  • All walls and ceilings should be plastered
  • There should be no holes remaining in floors or ceilings
  • Testers will require access to all rooms on all levels

Pre-completion sound testing is a building regulation requirement for all purpose built & “formed by material change of use” (i.e. refurbished) properties since 2003. Sound testing is undertaken in a percentage of properties in each development to ensure that the separating walls & floors between habitable rooms of neighbouring properties meet the minimum requirements as defined by Approved Document E, commonly referred to as ADE.

From 2003, Approved Document E states that all new UK builds must undergo pre-completion sound insulation testing. New builds must achieve impact sound test results of no more than 62dB L’nTw and airborne sound loss of no less than 45dB DnTw+Ctr. Converted properties must achieve impact results of 64dB L’nTw or lower and airborne sound loss of no less than 43dB DnTw+Ctr. Approved Document E sets out details pertaining to the resistance to the passage of sound.

This Approved Document, as part of UK Building Regulations helps to ensure that newly built or converted houses and residencies, flats and residential spaces and other relevant buildings are constructed to minimum standards that provide ‘reasonable resistance to sound from other parts of the same building and from adjacent buildings.’ All of our tests are fully compliant with Approved Document E and our expert team have been carrying out compliant tests for many years, for thousands of satisfied customers throughout the UK.

We understand the sectors our clients work in. Our advice is not only technically robust but also practical and helpful to our client’s particular situation. At AF Acoustics, we always look at the bigger picture and work towards the ultimate development goal.

In order to provide you best solutions, we will listen to your needs, present you with robust solutions and deliver acoustic consultancy through our considerable experience. Our ever-expanding knowledge-base allows us to provide cost-effective and streamlined solutions.

Our consultants are very experienced and have a proven track record on both small scale projects and major projects. As we are a lean and small company, we have lower overheads and therefore offer exceptional value for money.

Airborne sound (or airborne noise) is sound that is transmitted through the air. Airborne Sound Insulation is the insulation against noise originating in air, e.g. voices, music, motor traffic, wind. The greater the airborne sound insulation between two rooms, the lower the resulting sound level in the receiving room.

This is unlike Impact Sound Insulation that protects against noise originating directly on a structure by blows or vibration e.g. footsteps above, furniture being moved, drilling and hammering the structure.

Call us today for a quote on 020 3372 4430
Or you can email us at info@af-acoustics.com
Image module

Adrian Finn

AF Acoustics lead Acoustic Engineer, Adrian is your first port of call for all sound insulation testing questions enquiries and surveys.

Working Hours

  • Monday 08:00 - 18:00
  • Tuesday 08:00 - 18:00
  • Wednesday 08:00 - 18:00
  • Thursday 08:00 - 18:00
  • Friday 08:00 - 18:00
  • Saturday Closed